Intermatic PE153P

Intermatic PE153P 3-Circuit Digital Timer Instruction Manual

Model: PE153P

Okwu mmalite

The Intermatic PE153P is a versatile 3-circuit digital timer designed for automatic control of electrical loads. This 24-hour control mechanism allows for precise scheduling of various applications, including lighting, heating, air conditioning, and pool or spa pumps. Each circuit can manage loads up to 17 amps. This manual provides essential information for the safe installation, programming, operation, and maintenance of your PE153P digital timer.

Intermatic PE153P 3-Circuit Digital Timer in Rainproof Enclosure

Foto 1: Intermatic PE153P 3-Circuit Digital Timer. This image shows the timer unit with its rainproof enclosure open, revealing the digital display, control buttons, and wiring terminals. The enclosure is designed to protect the internal components from environmental elements.

Ozi nchekwa

Na-agbaso ihe ndị a dị mkpa mgbe niile iji belata ihe egwu nke ọkụ, ọkụ eletrik, ma ọ bụ mmerụ ahụ:

  • Installation must be performed by a qualified electrician and in accordance with all national and local electrical codes.
  • Disconnect power at the circuit breaker or fuse box before installing or servicing the timer.
  • Ensure the timer is properly grounded.
  • Do not exceed the maximum load ratings for each circuit (17 amps).
  • This device is intended for outdoor use and is housed in a rainproof enclosure. Ensure the enclosure is securely closed after installation and servicing.

Nwụnye na Nhazi

Ịkwanye ogige ahụ

  1. Select a suitable location for mounting the timer. The location should be easily accessible for programming and maintenance, and protected from direct sunlight if possible to prolong LCD life.
  2. Use appropriate mounting hardware (not included) to secure the enclosure to a flat, vertical surface. Ensure the enclosure is level.

Ntuziaka wiring

Ịdọ aka ná ntị: Disconnect power at the main service panel before wiring. Failure to do so may result in serious injury or death.

  • Open the timer enclosure.
  • Identify the input terminals (LINE 1, LINE 2, NEUTRAL) and output terminals for each of the three circuits (LOAD 1, LOAD 2, LOAD 3).
  • Connect the incoming power supply wires to the appropriate input terminals. For 120V operation, connect LINE 1 and NEUTRAL. For 240V operation, connect LINE 1 and LINE 2.
  • Connect the load wires for each device you wish to control to the corresponding output terminals.
  • Ensure all wire connections are tight and secure. Use copper conductors only, rated for at least 75°C.
  • Close and secure the enclosure door.

Ntuziaka ọrụ

Initial Power-Up and Time Setting

  1. Restore power to the timer at the main service panel.
  2. The LCD display will illuminate. If the display is blank, check power connections.
  3. Pịa Mmemme bọtịnụ iji tinye ọnọdụ mmemme.
  4. Jiri ihe UP na N'ala arrows to set the current time (hour and minute).
  5. Pịa Banye iji gosi ntọala ọ bụla.
  6. Set the current day of the week using the UP na N'ala arrows, then press Banye.

Usoro mmemme

The PE153P offers seven preprogrammed modes and custom programming. Refer to the detailed programming section in the full manual for advanced settings.

  1. Pịa Mmemme repeatedly to cycle through the available circuits (CIRCUIT 1, CIRCUIT 2, CIRCUIT 3).
  2. Once the desired circuit is selected, press Banye to begin setting ON/OFF times.
  3. Jiri UP na N'ala arrows to set the ON time, then press Banye.
  4. Repeat for the OFF time.
  5. Select the days of the week for this schedule to be active.
  6. Pịa Mmemme to save and exit, or to move to the next program event.

Ntugharị akwụkwọ ntuziaka

To manually turn a circuit ON or OFF outside of its programmed schedule, press the corresponding KWURU button for that circuit. The override will remain active until the next programmed event or until manually cancelled.

Nlekọta

The Intermatic PE153P digital timer requires minimal maintenance. Periodically inspect the enclosure for any signs of damage or wear. Ensure the door seal is intact to maintain its rainproof rating. Keep the display and buttons clean and free of debris. No user-serviceable parts are inside the sealed unit beyond the wiring terminals.

Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Ngosipụta bụ oghere.Enweghị ike na unit.Check circuit breaker/fuse. Verify wiring connections.
Ibu anaghị agbanyu/gbanyụọ dịka e si hazie ya.Incorrect programming; Manual override active; Faulty wiring; Load exceeding capacity.Review programming schedule. Check for active manual override. Inspect wiring. Ensure load is within 17A per circuit.
Oge ezighi ezi.Time not set correctly; Power interruption.Reset current time and day. The internal battery should maintain time during short power outages.

If troubleshooting steps do not resolve the issue, contact Intermatic customer support.

Nkọwapụta

NlereanyaPE153P
ỤdịIntermatic
Ntinye Voltage120/240 VAC, 60Hz
Ọnụọgụ nke sekit3 independent circuits
Ibu Ibu kwa sekit17 Amps (resistive/inductive), 1000W tungsten, 3 HP
Ụdị mkpuchiRainproof (Type 3R)
Atụmatụ igodoLCD Readout, Multivoltage Input/Output, Countdown, Override, Freeze Protection, Heater Protection
Ibu Ibu2.55 pound

Akwụkwọ ikike na nkwado

Ozi akwụkwọ ikike

Intermatic products are designed for reliability and performance. For specific warranty details, please refer to the warranty card included with your product or visit the official Intermatic websaịtị. Debe ihe akaebe nke ịzụrụ maka akwụkwọ ikike.

Nkwado ndị ahịa

For technical assistance, programming questions, or to report a problem, please contact Intermatic customer support. Visit the Intermatic Store on Amazon ma ọ bụ onye ọrụ ha websaịtị maka ozi kọntaktị na ihe ndị ọzọ.

Akwụkwọ ndị emetụtara - PE153P

Tupuview Intermatic PF1103T PF1103MT Freeze Protection Control Installation Operation Service Manual
This manual provides detailed installation, operation, and troubleshooting instructions for the Intermatic PF1103T and PF1103MT freeze protection controls, designed for pool and spa equipment. Includes wiring diagrams and warranty information.
Tupuview Intermatic All-Plastic Rainproof Time Switch Enclosure Installation Instructions
Detailed installation guide for the Intermatic all-plastic rainproof time switch enclosure, covering case mounting, conduit connections, and grounding requirements according to the National Electric Code.
Tupuview Intermatic P1161 Portable Pool & Spa Timer Owner's Manual - Safety, Setup, and GFCI Testing
Comprehensive owner's manual for the Intermatic P1161 Portable Safety Pool & Spa Timer. Includes important safety instructions, how to set the timer, warranty information, GFCI explanation, troubleshooting guide, and monthly testing procedures.
Tupuview Intermatic PF1000 Series PF1222TB1 Subpanel Installation, Operation & Service Manual
Comprehensive installation, operation, and service manual for the Intermatic PF1000 Series PF1222TB1 Subpanel, a two-circuit pool equipment control with freeze and heater protection.
Tupuview Intermatic P1131 Portable Heavy Duty Pool & Spa Timer Owner's Manual
Owner's manual for the Intermatic P1131 Portable Heavy Duty Pool & Spa Timer. Provides setup instructions, safety warnings, troubleshooting guide, and warranty information for convenient and energy-saving operation of pool and spa equipment.
Tupuview Intermatic PF1102T/PF1102MT Freeze Protection Controls: Installation, Operation & Service Manual
Comprehensive guide for installing, operating, and servicing Intermatic PF1102T and PF1102MT freeze protection controls for pools and spas. Includes safety warnings, wiring diagrams, and troubleshooting.