Okwu mmalite
The Leviton 8215-PLC is a 15 Amp, 125 Volt, NEMA 5-15P, 2-pole, 3-wire, straight blade grounding plug designed for hospital grade applications. This transparent plug features a power indication LED, allowing for visual confirmation of power presence. Constructed with a super tough nylon body and solid brass blades and contacts, it offers durability, superior conductivity, and resistance to impact, abrasion, and chemicals.
Image: The Leviton 8215-PLC Hospital Grade Plug, transparent with a green power indicator.
Ozi nchekwa
Ịdọ aka ná ntị: To avoid fire, shock, or death, always turn off power at the circuit breaker or fuse box before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.
- Always disconnect power before inspecting or working on electrical connections.
- Gbaa mbọ hụ na njikọ waya niile echekwara na mkpuchi nke ọma.
- Do not use this plug with damaged or frayed cords.
- This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm (Proposition 65 warning). Wash hands after handling.
Ntọala na nwụnye
This section provides instructions for properly wiring the Leviton 8215-PLC plug to a power cord. Ensure the power cord is appropriate for the intended application and current rating.
Ngwa achọrọ:
- Phillips isi sikruuokwomoto
- Waya waya
- Utility knife (optional, for outer jacket)
Ntuziaka waya:
- Kwadebe eriri ahụ: Carefully strip the outer jacket of your power cord to expose approximately 1.5 to 2 inches of the insulated wires (typically black, white, and green/bare copper). Then, strip about 1/2 inch of insulation from the ends of the black (hot), white (neutral), and green/bare copper (ground) wires.
- Kwụpụ plọg ahụ: Unscrew the assembly screws on the plug body to separate the front and back sections. Slide the back cover and cord clamp components onto the power cord in the correct orientation.
- Jikọọ wires: The Leviton 8215-PLC features internal wiring chambers designed to isolate individual conductors. Connect the wires to the appropriate terminals:
- Green/Bare Copper Wire: Jikọọ na akwụkwọ ndụ akwụkwọ ndụ (grounding) screw terminal.
- waya ọcha: Jikọọ na ọlaọcha (neutral) screw terminal.
- waya ojii: Jikọọ na ọla kọpa (hot) screw terminal.
- Secure the Cord Clamp: Position the cord clamp around the power cord and tighten the screws to provide a secure grip without damaging the cord's outer jacket. This prevents strain on the wire connections.
- Jikọtaghachi plọg ahụ: Carefully align the front and back sections of the plug, ensuring no wires are pinched. Securely fasten the assembly screws.
Foto: nso nso view of the internal wiring chambers, showing isolated conductors and screw terminals.
Image: The plug's cord clamp mechanism, designed to secure the power cord and prevent strain.
Ntuziaka ọrụ
Once properly wired, the Leviton 8215-PLC plug is ready for use.
- Jikọọ na Ike: Insert the plug firmly into a compatible 125V, 15A NEMA 5-15R receptacle.
- Verify Power Indication: The long-life LED bulb on the transparent body of the plug will illuminate green when power is present at the device. This provides a quick visual confirmation that the circuit is live and the plug is receiving power.
- Ịkwụsị: To disconnect, grasp the plug body firmly and pull it straight out from the receptacle. Do not pull by the cord.
Nlekọta
Regular inspection and basic maintenance can help ensure the longevity and safe operation of your Leviton 8215-PLC plug.
- Nyocha oge: Regularly check the plug and cord for any signs of damage, such as cracks, frayed insulation, bent blades, or discoloration. If any damage is observed, discontinue use and replace the plug or cord as necessary.
- Nhicha: Disconnect the plug from the power source before cleaning. Wipe the exterior of the plug with a dry, clean cloth. Do not use liquid cleaners or solvents, as these may damage the material or internal components.
- Lelee njikọ: If the plug is frequently moved or subjected to stress, periodically check the tightness of the assembly screws and cord clamp screws to ensure secure connections.
Nchọpụta nsogbu
If you encounter issues with your Leviton 8215-PLC plug, refer to the following troubleshooting steps:
- Ihe ngosi LED adịghị ọkụ:
- Ensure the plug is fully inserted into a live receptacle.
- Check the circuit breaker or fuse for the outlet to ensure power is supplied.
- Verify the wiring connections inside the plug are secure (refer to Setup and Installation).
- Lelee eriri ike maka mmebi ọ bụla.
- Loose Connection or Intermittent Power:
- Disconnect power and re-open the plug to check all wire terminal screws for tightness.
- Ensure the cord clamp is securely tightened to prevent strain on the internal connections.
- Mmebi anụ ahụ: If the plug body, blades, or cord show signs of physical damage, replace the plug immediately.
Nkọwapụta
| Nọmba nlereanya | 8215-PLC |
| Ampoge | 15 Amps |
| Voltage | 125 volts |
| Nhazi NEMA | 5-15P |
| Osisi / waya | 2 Pole, 3 Wire Grounding |
| Ọkwa ngwaahịa | Ọkwa ụlọ ọgwụ |
| Ihe onwunwe | Super Tough Nylon (Body), Thermoplastic (Back Cover) |
| Agba | N'ụzọ doro anya |
| Ngosipụta ike | Igwe ọkụ ọkụ LED |
| Nkwenye | UL 498, CSA C22.2, NOM 057 |
| Ibu Ibu | 0.01 ounces |
| Akụkụ ngwaahịa | 9.38 x 7.13 x 9 sentimita asatọ |
Ozi akwụkwọ ikike
This Leviton product is covered by the manufacturer's limited lifetime warranty. For detailed information regarding warranty terms, conditions, and registration, please refer to the official Leviton website or contact Leviton customer service directly. Keep your proof of purchase for warranty claims.
Nkwado ndị ahịa
For technical assistance, product inquiries, or further support, please visit the official Leviton website or contact their customer service department. Contact information can typically be found on the Leviton webngwugwu saịtị ma ọ bụ ngwaahịa.
Leviton Websaịtị: www.leviton.com