ESAB 0781-0589

Ntuziaka Ntuziaka maka Njikwa Gas Silinda Silinda LPG nke ESAB SR-461B-510

Nle: 0781-0589

1. Okwu mmalite

This manual provides essential instructions for the safe and effective installation, operation, and maintenance of your ESAB SR-461B-510 Industrial Gas Regulator. This single-stage regulator is designed for use with LP Gas cylinders, featuring a CGA-510 inlet connection and a 9/16 In.-18 M LH outlet connection.

Please read this manual thoroughly before attempting to install or operate the regulator. Retain this manual for future reference.

1.1. Ozi nchekwa

Ịdọ aka ná ntị: Misuse of this product may cause explosion and personal injury. Always read and understand all ASME-B40.100 standards and apparatus installation/operating instructions before using.

Ngwaahịa a nwere kemịkalụ ndị Steeti California maara na ha na-akpata ọrịa kansa na nkwarụ ọmụmụ ma ọ bụ mmerụ ahụ ndị ọzọ metụtara ọmụmụ nwa (ịdọ aka ná ntị California Proposition 65).

  • Always ensure proper ventilation when working with LP gas.
  • Never use oil or grease on regulator or cylinder connections.
  • Inspect the regulator and connections for damage before each use.
  • Use only with compatible LP gas cylinders and connections.
  • Do not modify the regulator in any way.

1.2. Ihe ngwugwu

  • ESAB SR-461B-510 Regulator Unit
  • Ntuziaka Ntuziaka (akwụkwọ ntuziaka a)

2. Ntọala na nwụnye

Follow these steps for safe installation of the regulator to an LP gas cylinder.

  1. Ensure the cylinder valve is closed and the regulator adjusting screw is fully backed out (turned counter-clockwise until loose).
  2. Inspect the cylinder valve outlet and regulator inlet connection (CGA-510) for any damage or debris.
  3. Connect the regulator inlet nut to the cylinder valve outlet. The CGA-510 connection is designed for LP gas. Tighten securely with a wrench.
  4. Connect the outlet hose (not included) to the regulator's 9/16 In.-18 M LH outlet connection. Ensure this connection is also tight.
  5. Perform a leak test using a suitable leak detection solution on all connections before opening the cylinder valve.
ESAB SR-461B-510 LPG Cylinder Gas Regulator with two gauges and a T-handle adjusting screw.

Foto 1: ESAB SR-461B-510 LPG Cylinder Gas Regulator. This image displays the brass regulator body, two pressure gauges, and a T-handle adjusting screw. The inlet connection (CGA-510) is visible on the right, designed for LP gas cylinders. The left gauge, which in this image shows a scale for Acetylene (0-15 psi), would indicate the delivery pressure for LPG. The right gauge indicates the cylinder pressure (0-400 psi).

3. Ntuziaka ọrụ

Once the regulator is securely installed and leak-tested, follow these steps to operate.

  1. Slowly open the cylinder valve. The inlet gauge (right gauge, 0-400 psi) will indicate the cylinder pressure.
  2. Turn the regulator adjusting screw (T-handle) clockwise to increase the delivery pressure. The delivery pressure gauge (left gauge, 0-60 psig) will show the regulated pressure. Adjust to the desired working pressure, typically within the 2 to 40 psig range for this model.
  3. Once the desired pressure is set, you can begin using the LP gas.
  4. To shut down, first close the cylinder valve.
  5. Allow the gas in the system to bleed off until both gauges read zero.
  6. Turn the regulator adjusting screw counter-clockwise until it is loose to relieve spring tension.

The regulator is designed for a flow rate of approximately 2500 SCFH (Standard Cubic Feet per Hour).

4. Nlekọta

Regular maintenance ensures the longevity and safe operation of your regulator.

  • Nyocha: Before each use, visually inspect the regulator for any signs of damage, such as dents, cracks, or worn threads. Check gauges for proper function.
  • Nhicha: Keep the regulator clean and free from oil, grease, or other contaminants. Use a clean, dry cloth. Do not use harsh chemicals.
  • Nnwale mkpofu: Periodically perform a leak test on all connections, even if no issues are suspected.
  • Nchekwa: When not in use, store the regulator in a clean, dry place, disconnected from the cylinder.

Do not attempt to repair the regulator yourself. Refer all repairs to qualified personnel or contact ESAB customer support.

5. Nchọpụta nsogbu

Akụkụ a na-ekwu maka nsogbu ndị ị nwere ike izute.

  • Enweghị usoro gas:
    • Ensure the cylinder valve is fully open.
    • Check if the cylinder contains gas.
    • Verify the regulator adjusting screw is turned clockwise to set a delivery pressure.
    • Inspect for blockages in the hose or equipment.
  • Pressure Not Holding:
    • Perform a leak test on all connections (cylinder, regulator inlet, regulator outlet, hose).
    • Gbaa mbọ hụ na agbachiela njikọ niile nke ọma.
    • If leaks persist or the regulator itself is suspected, discontinue use and contact support.
  • Inaccurate Gauge Readings:
    • Gauges are factory calibrated. If readings appear consistently incorrect, the gauge may be faulty. Discontinue use and contact support.

For issues not covered here, or if troubleshooting steps do not resolve the problem, contact ESAB customer support.

6. Nkọwapụta

NjirimaraNkọwa
Nọmba nlereanya0781-0589 (SR-461B-510)
Ụdị nhaziIndustrial Gas Regulator, Single Stage
Gas ServiceLP gas (LPG)
Njikọ mbataCGA-510
Njikọ ọpụpụ9/16 In.-18 M LH
Delivery Pressure Range2 ruo 40 pg
Delivery Pressure Gauge60 psig (2-1/2 In. Gauge Size)
Inlet Gauge400 psig (2-1/2 In. Gauge Size)
Ọnụego mgbaba (ihe dị ka)2500 SCFH
Ihe onwunweBrass akpara akpa
Ogologo mkpokọta7-1/4 nke.
Akụkụ ngwaahịa6 x 7 x 7 sentimita asatọ
Ibu Ibu5.13 pound
Onye nrụpụtaVictor Technologies (ESAB)
Mba onye siUnited States

7. Akwụkwọ ikike na nkwado

For warranty information, technical support, or service inquiries, please contact ESAB customer service directly. Refer to the official ESAB webngwugwu saịtị ma ọ bụ ngwaahịa maka nkọwa kọntaktị kachasị ugbu a.

When contacting support, please have your model number (0781-0589) and purchase information available.

Akwụkwọ ndị emetụtara - 0781-0589

Tupuview ESAB PP 350w Torch Quick Start Guide - Setup and Operation
Concise guide for setting up and operating the ESAB PP 350w welding torch, including connection, adjustments, and safety information.
Tupuview ESAB TRACFINDER WHEEL: Betjeningsvejledning og Teknisk Information
Denne betjeningsvejledning giver detaljerede instruktioner til installation, drift, vedligeholdelse og fejlfinding af ESAB TRACFINDER WHEEL svejsetraktor. Lær om tekniske specifikationer, sikkerhedsprocedurer og tilbehør.
Tupuview ESAB LAF 1001 / LAF 1001M Instruction Manual - Welding Power Source Guide
Comprehensive instruction manual for the ESAB LAF 1001 and LAF 1001M remote-controlled 3-phase welding power sources, covering installation, operation, maintenance, and safety for mechanised arc welding applications.
Tupuview Guía de funcionamiento del TRACFINDER WHEEL de ESAB
Manual de funcionamiento y guía de instalación para el carro de soldadura autónomo ESAB TRACFINDER WHEEL. Cubre especificaciones técnicas, operaciones, mantenimiento y solución de problemas.
Tupuview ESAB TRACFINDER RAIL: Manual de Operação e Instalação
Este manual fornece instruções detalhadas sobre a instalação, operação, segurança, manutenção e solução de problemas do sistema de soldagem automatizada ESAB TRACFINDER RAIL, projetado para aplicações industriais.
Tupuview Manual de Instrucciones ESAB TRACFINDER WHEEL
Manual de instrucciones completo para el carro de soldadura ESAB TRACFINDER WHEEL. Cubre instalación, operación, panel de control, mantenimiento, resolución de averías y especificaciones técnicas.