Watts 007 QT

Watts 007 QT 1/2-inch Double Check Valve Assembly Instruction Manual

1. Ngwaahịa gafereview

The Watts 007 QT 1/2-inch Double Check Valve Assembly is engineered to prevent the backflow of contaminated water into a potable water supply system. This device is suitable for non-health hazard, continuous pressure applications. Its robust bronze body construction ensures durability and ease of maintenance. The assembly provides protection against both backsiphonage and backpressure backflow, safeguarding water quality.

Atụmatụ gụnyere:

Watts 007 QT 1/2-inch Double Check Valve Assembly

Image 1.1: Watts 007 QT 1/2-inch Double Check Valve Assembly. This image displays the bronze body construction and overall compact design of the valve assembly.

2. Ozi nchekwa

Ịdọ aka ná ntị: Improper installation or maintenance of this device can lead to serious injury or property damage. Always adhere to local plumbing codes and regulations.

3. Ntọala na nwụnye

The Watts 007 QT Double Check Valve Assembly is designed for horizontal or vertical installation, depending on local codes and specific model requirements. Ensure proper orientation for optimal performance.

3.1 Nyochaa nwụnye tupu etinye ya

3.2 Nzọụkwụ nwụnye

  1. Gbanyụọ inye mmiri: Locate the main water shut-off valve and turn off the water supply to the area where the backflow preventer will be installed. Drain the system to relieve pressure.
  2. Họrọ ebe: Choose an accessible location for installation that allows for future maintenance and testing. The device should be installed downstream of the main water meter and upstream of any connections that could introduce contaminants.
  3. Prepare Piping: Cut and prepare the existing piping to accommodate the 1/2-inch inlet and outlet connections of the valve assembly. Ensure pipe ends are clean and free of burrs.
  4. Wụnye valvụ: Install the Watts 007 QT assembly into the pipeline, ensuring the flow arrow on the valve body points in the direction of water flow. Use appropriate thread sealant on all connections.
  5. Mechie njikọ: Securely tighten all connections to prevent leaks, but do not overtighten, which could damage the bronze body or fittings.
  6. Open Water Supply: Slowly open the main water shut-off valve to gradually repressurize the system. Check all connections for leaks.
  7. Nnwale izizi: After installation, the device should be tested by a certified backflow prevention device tester to ensure proper operation and compliance with local regulations.

4. Ọrụ

The Watts 007 QT Double Check Valve Assembly operates automatically to prevent backflow. It contains two independently operating check valves that close to prevent reverse flow when a backflow condition occurs.

5. Nlekọta

Regular maintenance and testing are crucial to ensure the continued proper function of your Watts 007 QT Double Check Valve Assembly. This device is designed for ease of service.

5.1 Nnwale Kwa Afọ

Local regulations typically require annual testing of backflow prevention devices by a certified tester. This ensures the device is operating correctly and providing the required level of protection.

5.2 Ije Ozi na Mmezi

The modular construction and top-entry design facilitate easy servicing. If testing indicates a malfunction, the internal components can be accessed and replaced without removing the entire assembly from the pipeline.

6. Nchọpụta nsogbu

This section provides guidance for common issues. For complex problems or issues related to backflow prevention, always consult a certified professional.

6.1 Okwu nkịtị na Ngwọta

If you encounter issues not listed here or are unsure about a repair, contact Watts customer support or a qualified plumbing professional.

7. Nkọwapụta

Nọmba nlereanya007 QT (Part # 0062131)
Nha1/2 nke anụ ọhịa
Ihe onwunweBronze, Silicone
Emecha mpụtaỌla
Ogo njikọ mbata0.5 sentimita asatọ
Ụdị njikọ mbataMgbakọ Valve nlele ugboro abụọ
Nha Njikọ Ọpụpụ0.5 sentimita asatọ
Ụdị Njikọ ọpụpụFNPT
Nrụgide arụ ọrụ kacha175 psi (12.06 mmanya)
Ọnụọgụ nke ọdụ ụgbọ mmiri2
Ibu Ibu3.45 pound
Akụkụ ngwaahịa (L x W x H)1 x 0.39 x 0.39 sentimita asatọ
Nkọwapụta MetASSE 1015, AWWA C510, CSA B64.5, IAPMO PS31

8. Akwụkwọ ikike na nkwado

For specific warranty information regarding your Watts 007 QT Double Check Valve Assembly, please refer to the documentation included with your purchase or visit the official Watts webEbe a na-edebe akwụkwọ ikike. Usoro akwụkwọ ikike na-ekpuchi ntụpọ nrụpụta n'okpuru ojiji na ọrụ nkịtị.

8.1 Nkwado ndị ahịa

If you require technical assistance, have questions about installation, operation, or maintenance, or need to inquire about replacement parts, please contact Watts customer support:

When contacting support, please have your product model number (007 QT) and any relevant purchase information readily available.

Akwụkwọ ndị emetụtara - 007 QT

Tupuview Ngwa GBS (007-SS-GBS) - Data Teknụzụ
Technical specifications, product codes, dimensions, and features for the Watts 007-SS-GBS Stainless Steel Double Check Valve with Geared Butterfly Valve and Strainer. Designed for backflow prevention in medium and low hazard installations.
Tupuview Watts Series 709, LF709, 709DCDA Double Check Valve Assemblies: Installation, Maintenance, and Repair Manual
Comprehensive guide for the installation, maintenance, and repair of Watts Series 709, LF709, and 709DCDA Double Check Valve Assemblies and Double Check Detector Assemblies, covering sizes 2½" to 10". Includes installation guidelines, servicing procedures, troubleshooting, and information on add-on monitoring kits.
Tupuview Watts Series 757, 757DCDA, LF757DCDA Double Check Valve Assemblies Installation, Maintenance, and Repair Manual
Comprehensive guide for installing, maintaining, and repairing Watts Series 757, 757DCDA, and LF757DCDA Double Check Valve and Detector Assemblies, covering procedures, troubleshooting, and warranty information.
Tupuview Watts 007-SS-LBS Igwe anaghị agba nchara nke nwere valvụ nlele abụọ nke Watts.
Mpempe akwụkwọ data teknụzụ maka Watts 007-SS-LBS Silver Stallion Stallion Double Check Valve Kit, nke nwere akụkụ, koodu ngwaahịa, nkọwapụta teknụzụ, na usoro njirimara maka nchekwa mmiri.
Tupuview Watts Series 800M4, LF800M4 Pressure Vacuum Breaker Assemblies: Installation, Maintenance, and Repair Manual
Comprehensive guide for installing, maintaining, and repairing Watts Series 800M4 and LF800M4 Pressure Vacuum Breaker Assemblies. Covers safety, installation procedures, servicing, freeze protection, and warranty.
Tupuview Watts Series PVS-7000 Flood Protection Valve Station with SentryPlus Alert Technology
Nkachasị nkaview of the Watts Series PVS-7000 Flood Protection Valve Station, featuring SentryPlus Alert technology for automatic flood detection and shutdown. Includes specifications, installation guidance, and features for preventing property damage.