1. Ntuziaka nchekwa dị mkpa
Please read these instructions carefully before installation and use. Failure to follow these instructions may result in property damage, personal injury, or death.
- This appliance must be installed by a qualified electrician and plumber in accordance with all local and national regulations.
- Ensure the electrical supply matches the specifications of the appliance (230 V, 3.5 kW).
- Do not operate the appliance if it is damaged or not functioning correctly.
- Do not block the water outlet or tamper na valvụ enyemaka nrụgide.
- This unit is designed for pressureless operation. Only use the special mixer tap supplied with the unit.
- Debe ụmụaka pụọ na ngwa ngwa mgbe a na-arụ ọrụ.
- Kwụpụ ọkụ ọkụ tupu ime nrụzi ma ọ bụ ihicha ọ bụla.
2. Ngwaahịa gafereview
The CLAGE M3/SMB is a compact, hydraulically controlled small instantaneous water heater designed for over-sink installation. It provides hot water instantly for a single tap, making it ideal for hand washing or small dishwashing tasks. The unit features an effective bare-wire heating system (IES®) and comes with a special mixer tap for wall connection.

This image displays the CLAGE M3/SMB small instantaneous water heater unit mounted above a chrome-finished mixer tap. The water heater unit is a compact, rectangular, silver-colored device designed for over-sink installation. The mixer tap features two control knobs and a curved spout.
3. Nka na ụzụ nkọwa
| Nkọwapụta | Uru |
|---|---|
| Nọmba nlereanya | M3/SMB |
| Mpụta ike | 3.5 kW |
| Elu ọnụ Voltage | 230 V |
| Njikọ Ọdụdọ | 1 AC/N/PE, Plug-ready |
| Akụkụ (H x W x D) | 135 x 186 x 87 mm |
| Ibu | Ihe ruru. 1.92 n'arọ |
| Klas nchekwa | IP25 |
| Njikọ mmiri | 3/8 nke anụ ọhịa |
| Nrụgide arụ ọrụ | Pressureless |
| Ụdị nkwụnye | Wall-mounted, Over-sink |
4. Nwụnye (Ntọala)
Ọkachamara ruru eru ga-arụrịrị nrụnye.
4.1 Nwepu
- Jiri nlezianya wepụ ihe niile dị na nkwakọ ngwaahịa.
- Check for any visible damage. Do not install if damaged.
- Ensure all parts listed in the packing contents are present.
4.2 Ịtinye Unit
- Select a suitable wall location directly above the sink, ensuring sufficient space for maintenance and operation.
- Use the variable metal wall bracket to mark drilling points.
- Gwuo oghere ma tinye plọg mgbidi kwesịrị ekwesị.
- Securely fasten the wall bracket to the wall.
- Mount the water heater unit onto the bracket.
4.3 Njikọ mmiri
- Connect the cold water supply to the designated inlet on the mixer tap (usually marked blue).
- Connect the hot water outlet from the unit to the designated inlet on the mixer tap (usually marked red).
- Ensure all connections are tight to prevent leaks. Use appropriate sealing materials.
- Open the main water supply and check for leaks.
- Before electrical connection, flush the unit by opening the tap until water flows freely and air is expelled.
4.4 Njikọ eletrik
- Gbaa mbọ hụ na agbanyụrụ isi ọkụ eletrik na mgbanyụ sekit.
- Connect the appliance to a dedicated 230 V, 3.5 kW electrical circuit. The unit is plug-ready.
- Verify proper grounding.
- Once connections are secure, switch on the main power supply.
5. Ọrụ
5.1 Ojiji mbụ
- After installation and electrical connection, ensure the unit is completely filled with water by opening the cold water tap until water flows steadily.
- Turn the hot water knob on the mixer tap. The heating element will activate, and hot water will begin to flow after a short delay.
- Adjust the water temperature by mixing hot and cold water using the mixer tap controls.
5.2 Ojiji kwa ụbọchị
- To obtain hot water, turn the hot water knob on the mixer tap. The unit will heat water as it flows through.
- To obtain cold water, turn the cold water knob.
- Adjust the flow rate and temperature as desired using the tap controls.
- The unit is designed for continuous flow within its specified capacity.
6. Nlekọta
Regular maintenance ensures optimal performance and longevity of your CLAGE M3/SMB water heater.
- Na-ehicha Mpụga: Jiri nwayọ hichaa mpụta nke otu ahụ, damp akwa . Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
- Ebelata: Depending on water hardness, limescale can build up in the heating system. If you notice a decrease in hot water flow or temperature, the unit may need descaling. This procedure should be performed by a qualified technician.
- Lelee njikọ: Periodically inspect water and electrical connections for any signs of leaks or wear.
- Mixer Tap Maintenance: Clean the aerator of the mixer tap regularly to remove any debris or limescale buildup that might restrict water flow.
7. Nchọpụta nsogbu
Tupu ị kpọtụrụ ndị ahịa, biko gaa na ntuziaka nchọpụta nsogbu ndị a:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Enweghị mmiri ọkụ | Enweghị ọkụ Water flow too low Mmejọ ihe kpo oku | Check circuit breaker and power connection Increase water flow at the tap Kpọtụrụ ọkachamara ruru eru |
| Low hot water flow | Igwe ikuku mechiri emechi Mwube nke limescale Nrụgide mmiri ezughi oke | Igwe ikuku dị ọcha Descale unit (professional service) Check main water supply pressure |
| Mmiri na-agbapụta site na unit ma ọ bụ njikọ | Njikọ rụrụ arụ Akara mebiri emebi Mmejọ nke ime | Tighten connections (do not overtighten) Replace seals (professional service) Kpọtụrụ ọkachamara ruru eru |
| Mmiri adịghị ọkụ nke ukwuu | Mmiri na-eru oke oke Mwube nke limescale | Reduce water flow at the tap Descale unit (professional service) |
If the problem persists after attempting these solutions, please contact a qualified technician or CLAGE customer support.
8. Akwụkwọ ikike na nkwado
For warranty information, technical support, or spare parts, please refer to the official CLAGE website or contact your local CLAGE dealer. Keep your purchase receipt as proof of purchase.