1. Okwu mmalite
This instruction manual provides essential information for the safe and correct assembly, installation, and use of your Bachmann 910200 Safety Assembly Plug. Please read these instructions carefully before proceeding with installation and retain them for future reference. This plug is designed for power cables with cross-sections of H03VV-F3G0.75, H03VV-F3G1.0, and H03VV-F3G1.5 mm².
2. Ozi nchekwa
ỊDỌ AKA NA NTỊ: Ihe ize ndụ nke ujo eletrik!
- Installation must only be carried out by a qualified electrician or a person with appropriate technical knowledge and experience in electrical wiring.
- Always disconnect the power supply before beginning any installation or maintenance work.
- Gbaa mbọ hụ na voltage and current ratings of the plug are compatible with your application. This plug is rated for 16 Amperes and 300 VAC.
- Do not use the plug if it is damaged or shows signs of wear.
- Ensure all connections are secure and correctly insulated to prevent short circuits or electric shock.
- This plug has an IP20 rating and is intended for use in dry indoor environments only. Do not use in wet or damp ọnọdụ.
- Always connect the earth wire (green/yellow) correctly to the earth terminal.
3. Ngwaahịa gafereview

Foto 1: N'ihu view of the assembled Bachmann 910200 Safety Assembly Plug, showing the two main pins and the earth contact.

Ọgụgụ 2: N'azụ view of the assembled Bachmann 910200 Safety Assembly Plug, showing the cable entry point.
The Bachmann 910200 is a white, break-resistant Schuko assembly plug designed for robust and secure electrical connections. It features a double earthing system for enhanced safety and is suitable for power cables with a cross-section of 0.75 mm², 1.0 mm², or 1.5 mm² (H03VV-F3G type cables).
Akụkụ ndị bụ isi:
- Ụdị: Schuko (Type F) assembly plug
- Agba: Ọcha
- Ihe: Plastic, break-resistant construction
- Sistemu ala: Double earthing for maximum safety
- Ndakọrịta eriri: H03VV-F3G0.75, H03VV-F3G1.0, H03VV-F3G1.5 mm²
- Enyere aha ugbu a: 16 Amperes
- Ogo Voltage: 300 VAC
- Klas nchedo: IP20 (for dry indoor use)
4. Ntọala na nwụnye
Follow these steps carefully to ensure a safe and correct installation of the Bachmann 910200 assembly plug. Ensure the power cable is disconnected from any power source before you begin.
Ngwa achọrọ:
- Waya waya
- Obere ewepu-isi sikruuokwomoto
- Small Phillips-head screwdriver (for housing screw)
- Wire ferrules (recommended for stranded wires)
Nzọụkwụ nwụnye:
- Open the Plug Housing: Locate the single Phillips-head screw on the side of the plug housing. Unscrew it and carefully open the plug. The housing is designed to hinge open.
- Kwadebe eriri:
- Carefully strip the outer insulation of your power cable (e.g., H03VV-F3G) to an appropriate length (approximately 4-5 cm), exposing the three inner wires (Live, Neutral, Earth).
- Strip about 6-8 mm of insulation from the end of each inner wire.
- If using stranded wires, it is highly recommended to crimp wire ferrules onto the stripped ends to ensure a secure and reliable connection.
- Tinye eriri ahụ: Thread the prepared cable through the cable entry point at the rear of the plug housing.
- Jikọọ wires:
- Earth (Ground) Wire: Connect the green/yellow wire to the central earth terminal (often marked with an earth symbol or brass-colored). Tighten the screw securely.
- Live (Phase) Wire: Connect the brown or black wire to one of the outer terminals. Tighten the screw securely.
- Waya na-anọpụ iche: Connect the blue wire to the remaining outer terminal. Tighten the screw securely.
- Ensure no stray wire strands are present that could cause a short circuit.
- Secure the Cable Strain Relief: Position the cable so that the outer insulation is firmly held by the internal cable strain relief clamps. Tighten the screws on the strain relief to prevent the cable from being pulled out of the plug. Do not overtighten, as this can damage the cable.
- Close the Housing: Carefully close the two halves of the plug housing, ensuring that no wires are pinched. Reinsert and tighten the Phillips-head screw on the side of the housing until it is snug. Do not overtighten.
- Nyocha ikpeazụ: Visually inspect the assembled plug to ensure all connections are secure, no bare wires are exposed, and the housing is properly closed.

Figure 3: The Bachmann 910200 plug opened, revealing the internal terminals for live, neutral, and earth connections, along with the cable strain relief.
5. Ntuziaka ọrụ
Once the Bachmann 910200 Safety Assembly Plug is correctly wired and assembled, it is ready for use.
- Insert the plug firmly into a compatible wall socket.
- Ensure the plug is fully seated and makes a secure connection.
- Do not force the plug into a socket.
- To disconnect, pull the plug directly from the socket. Do not pull by the cable.
6. Nlekọta
Regular maintenance ensures the longevity and safe operation of your plug.
- Keep the plug clean and free from dust and debris. Use a dry cloth for cleaning.
- Periodically inspect the plug and cable for any signs of damage, such as cracks, fraying, or discoloration.
- If any damage is observed, discontinue use immediately and replace the plug.
- Do not attempt to repair a damaged plug.
7. Nchọpụta nsogbu
If the appliance connected to the plug does not function, consider the following:
- Enweghị ike:
- Check if the wall socket is live by testing with another appliance.
- Gbaa mbọ hụ na etinyere plọg ahụ nke ọma n'ime oghere.
- Inspect the internal wiring of the plug (only if qualified and power is disconnected). Ensure all wires are securely connected to their respective terminals.
- Check the appliance's fuse or circuit breaker.
- Njikọ rụrụ arụ: If the plug feels loose in the socket, ensure the socket itself is not faulty. Do not use loose sockets.
Ọ bụrụ na nsogbu na-aga n'ihu, kpọtụrụ onye na-ahụ maka ọkụ eletrik.
8. Nkọwapụta
| Nọmba nlereanya: | 910200 |
| Akara: | Bachmann |
| Ụdị: | Schuko Assembly Plug |
| Agba: | Ọcha |
| Ihe: | Plastic |
| Enyere aha ugbu a: | 16 Amperes |
| Ogo Voltage: | 300 VAC |
| Ọnụọgụ mkpanaka: | 2 |
| Ọnụọgụ nke waya: | 3 (Live, Neutral, Earth) |
| Ndakọrịta eriri: | H03VV-F3G0.75, H03VV-F3G1.0, H03VV-F3G1.5 mm² |
| Klas nchedo: | IP20 |
| Akụkụ ngwaahịa (L x W x H): | 9.2 x 8.8 x 8.6 cm |
| Arọ: | 31.75 g |
| Nkwenye: | CE |
9. Akwụkwọ ikike na nkwado
Bachmann products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation provided with your purchase or visit the official Bachmann website. For technical support or inquiries, please contact Bachmann customer service through their official channels.