Bogen BG-UTI312

Bogen Multi-Zone Page Controller BG-UTI312 User Manual

Brand: Bogen | Model: BG-UTI312

Okwu mmalite

The Bogen Multi-Zone Page Controller BG-UTI312 is engineered for multi-zone paging in one-way audio applications, specifically designed for self-amplified speaker systems. Each output is capable of providing audio for up to 150 self-amplified speakers. This unit is compatible with all standard analog port types and offers extensive configuration options for various paging needs. This manual provides essential information for the proper installation, operation, and maintenance of your BG-UTI312 unit.

Ntọala na nwụnye

The BG-UTI312 comes with a pre-installed ZX3 module, providing three zones of paging capability. The system is expandable up to 12 zones by adding additional modules. Installation involves connecting the unit to your existing telephone system and self-ampndị na-ekwu okwu.

  • Mgbasa mpaghara: The unit is expandable up to 12 zones.
  • Ọnụ ụzọ ekwentị: Supports loop start trunk, ground start trunk, station access (analog ring-up), page port contact closure activation, and page port voice activation.
  • Nhazi: Features a simple 2-switch interface setup for initial configuration.
  • Kọntaktị inyeaka: Programmable activation of AUX contacts is available.
  • Zone Contacts: Includes a C-form contact per zone for flexible integration.
  • Ịnye ọkụ: Utilizes a 24V DC, 1A internal power supply.
  • Speaker Capacity: Provides audio drive for up to 150 one-way self-amplified speakers per zone.
  • Terminal Strips: Pluggable terminal strips facilitate easy wiring and maintenance.
Front panel of the Bogen BG-UTI312 Multi-Zone Page Controller showing various inputs, outputs, and controls.

Foto nke 1: This image displays the front panel of the Bogen BG-UTI312, highlighting the music inputs, limiter/threshold controls, interface type selectors, power indicators, and zone connections (1-3, 4-6, 7-9, 10-12).

Ntuziaka ọrụ

The BG-UTI312 offers a range of operational features for comprehensive paging and background music management.

  • Output Limiter: An adjustable output limiter with threshold control and an active indicator helps prevent audio distortion.
  • Egwu ndabere: Two background music busses are available, selectable per zone. The unit features two high-impedance transformer-isolated background music inputs with stereo combining inputs for these busses.
  • Paging Zone Groups: Up to 24 programmable paging zone groups can be configured, including:
    • All-Call paging zone group.
    • Auto Select paging zone group.
    • Override paging (activated via loop start trunk or page port contact closure).
    • Night Ringer (90V and contact closure activation) with a dedicated zone group.
    • Two Tone Triggers (tone and duration selectable, closure activated) with individual zone groups. Tone options include tone burst, chime, double chime, or slow whoop.
    • Code Calling with a dedicated zone group.
  • Ịkpọ oku: Supports 2 to 5 digit dialing with a flexible dialing plan for zone and zone group numbers.
  • Ụda: Includes Pre-Announce Tone, Confirmation Tone, and a Setup Tone to assist in volume setting.
  • Mmemme: DTMF programming is used for configuration. DTMF Block helps suppress DTMF tones over the paging system.

Nlekọta

The Bogen BG-UTI312 is designed for reliable operation with minimal maintenance.

  • Ebe nchekwa: Setup data is stored in non-volatile memory, eliminating the need for a backup battery.
  • Nhicha: Keep the unit clean and free from dust. Use a soft, dry cloth for cleaning. Avoid liquid cleaners.
  • Igwe ikuku: Hụ na ikuku dị mma gburugburu ngwaọrụ ahụ iji gbochie oke okpomọkụ. Ekpuchila oghere ikuku.
  • Njikọ: Periodically check all connections to ensure they are secure. The pluggable terminal strips allow for easy inspection and re-connection.

Nchọpụta nsogbu

If you encounter issues with your Bogen BG-UTI312, consider the following general troubleshooting steps. The microcontroller-based operation provides stable performance, but basic checks can resolve common problems.

  • Enweghị ike: Verify the power connection and check the fuse rating (1A/125V). Ensure the 24V DC power supply is functioning correctly.
  • No Paging Audio: Check all audio input and output connections. Confirm that the correct zone is selected and that the output limiter is not set too low. Verify telephone interface connections.
  • Audio gbagọrọ agbagọ: Adjust the output limiter threshold. Ensure input levels are not overdriving the system.
  • Incorrect Zone Paging: Review your dialing plan and zone group configurations. Ensure the correct digits are being dialed for the desired zone or group.
  • Background Music Issues: Check background music input connections and ensure the correct bus is selected for the zone. Verify input levels.

For persistent issues, consult a qualified technician or contact Bogen technical support.

Nkọwapụta

Akụkụ ngwaahịa19 x 7 x 6.5 sentimita asatọ
Ibu Ibu0.01 ounces
Onye nrụpụtaBogen
Nọmba nlereanyaBG-UTI312
Ịnye ọkụ24V DC, 1A (internal)
Ike mpaghara3 to 12 zones (expandable with modules)
Speaker CapacityUp to 150 one-way self-amplified speakers per zone
Paging Zone GroupsRuo 24 mmemme
Ebe nchekwaNon-volatile for setup data
Nhọrọ view of the Bogen BG-UTI312 Multi-Zone Page Controller.

Foto nke 2: This image provides another perspective of the Bogen BG-UTI312, showing the overall chassis and the arrangement of its various connection points and controls.

Ozi akwụkwọ ikike

The Bogen Multi-Zone Page Controller BG-UTI312 comes with a 2-afọ akwụkwọ ikike. Please retain your proof of purchase for warranty claims. For detailed terms and conditions, refer to the official warranty documentation provided with your product or visit the Bogen websaịtị.

Nkwado

For technical assistance, product inquiries, or service requests, please contact Bogen customer support. Refer to the contact information provided on the Bogen official website or in the packaging materials for the most current support channels.

Akwụkwọ ndị emetụtara - BG-UTI312

Tupuview Bogen UTI312 Zone Controller & Universal Telephone Interface Installation and Use Manual
Installation and use manual for the Bogen UTI312 Zone Controller with Universal Telephone Interface, detailing its features, setup, and operational guidelines for multi-zone paging and signaling systems.
Tupuview Bogen TPU Series Telephone Paging Amplifiers: Installation and Use Manual
Comprehensive installation and use manual for Bogen TPU35B, TPU60B, TPU100B, and TPU250 telephone paging amplifiers, covering setup, wiring, operation, and specifications.
Tupuview Bogen MCP35A Master Control Panel: Nwụnye na ntuziaka ojiji
Akwụkwọ ntuziaka a na-enye nrụnye zuru ezu, ọrụ, na nkọwa nka maka Bogen MCP35A Master Control Panel, usoro dị iche iche maka nkwurịta okwu ụzọ abụọ na nkesa mmemme na gburugburu dị iche iche.
Tupuview Bogen IH8A Reentrant Horn Loudspeaker - Product Specifications and Installation
Comprehensive details on the Bogen IH8A Reentrant Horn Loudspeaker, including its features, technical specifications, mounting and installation guide, and limited warranty information.
Tupuview Bogen Nyquist VoIP Intercom Module Configuration Guide (NQ-GA10P, NQ-GA10PV)
Detailed configuration guide for Bogen's Nyquist NQ-GA10P and NQ-GA10PV VoIP Intercom Modules. Covers setup, network settings, firmware updates, and standalone operation for IP paging and audio distribution systems.
Tupuview Bogen VAR1 Voice-Activated Relay: Technical Specifications and Operation
Detailed specifications, installation, operation, and warranty information for the Bogen VAR1 Voice-Activated Relay, a DPDT relay device for audio signal activation and muting.