This manual provides instructions for the installation, operation, and maintenance of the Intermatic T174 DPST 24 Hour Time Switch. This electromechanical timer is designed for controlling electrical loads over a 24-hour period.

Intermatic T174 DPST 24 Hour Time Switch with Type 1 Indoor Enclosure

Image: Intermatic T174 DPST 24 Hour Time Switch. This image shows the front view of the timer with its gray metal enclosure and the dial for setting time.

Ozi nchekwa

WARNING: Risk of electric shock. Installation and servicing must be performed by qualified personnel only. Disconnect power at the circuit breaker or fuse box before installing or servicing the timer.

  • Soro koodu na ụkpụrụ eletriki mpaghara mgbe niile.
  • Ensure the power supply matches the timer's voltage rating (208-277V AC).
  • Do not exceed the maximum current and horsepower ratings of the timer.
  • This device is intended for indoor use in a Type 1 enclosure.

Ihe ngwugwu

The Intermatic T174 Time Switch package typically includes:

  • One (1) Intermatic T174 Time Switch Unit
  • Ntuziaka ntuziaka
  • Two (2) Trippers for setting ON/OFF times

Ntọala na nwụnye

The Intermatic T174 is designed for fixed installation. Proper wiring is crucial for safe and correct operation.

Ịkwanye

  1. Choose a suitable indoor location for mounting the timer, ensuring it is protected from moisture and extreme temperatures.
  2. Securely mount the timer's enclosure to a wall or suitable surface using appropriate fasteners.

Wiring (DPST Configuration)

The T174 features a Double Pole, Single Throw (DPST) contact form, meaning it controls two independent circuits or a single 2-pole circuit simultaneously.

  1. DISCONNECT ALL POWER to the circuit at the main service panel before proceeding.
  2. Open the timer's enclosure.
  3. Connect the incoming power lines (L1 and L2 for 208-277V AC) to the designated "LINE" terminals on the timer.
  4. Connect the load wires (to the device being controlled) to the designated "LOAD" terminals. Ensure correct polarity if applicable.
  5. Gbaa mbọ hụ na njikọ waya niile siri ike na nchekwa.
  6. Close the timer's enclosure securely.
  7. Weghachite ike na sekit.

Consult a qualified electrician if you are unsure about any wiring procedures.

Ntuziaka ọrụ

The T174 uses a mechanical dial and trippers to set the ON/OFF schedule.

Isetịpụ Oge Ugbu A

  1. Rotate the timer dial clockwise until the current time aligns with the "TIME SET" arrow or indicator on the timer mechanism.
  2. Ensure AM/PM is correctly observed if the dial has such markings.

Setting ON/OFF Times

The timer comes with two trippers: one "ON" tripper and one "OFF" tripper. Additional trippers can be purchased separately (Extra Trippers 11Z965).

  1. Locate the "ON" tripper (typically silver or light-colored) and the "OFF" tripper (typically black or dark-colored).
  2. Snap the "ON" tripper onto the dial at the desired time you want the connected device to turn ON.
  3. Snap the "OFF" tripper onto the dial at the desired time you want the connected device to turn OFF.
  4. You can set up to 12 ON/OFF cycles per 24-hour period using additional trippers. The minimum time setting is 1 hour.

Ntugharị akwụkwọ ntuziaka

The T174 typically includes a manual override switch or lever. This allows you to temporarily turn the connected device ON or OFF without affecting the programmed schedule. Refer to the specific markings on your timer for the manual override function.

Day Skipper Function

The timer features a Day Skipper function, allowing you to prevent operation on specific days of the week. Consult the detailed instruction guide included with your unit for specific setup of this feature.

Nlekọta

The Intermatic T174 Time Switch is designed for reliable, long-term operation with minimal maintenance.

  • Periodically inspect the timer for any signs of damage or loose connections.
  • Keep the enclosure clean and free from dust and debris.
  • Do not attempt to lubricate internal components.

Nchọpụta nsogbu

Nsogbu Ihe nwere ike ime Ngwọta
Ngụ oge anaghị arụ ọrụ. No power to the timer. Check circuit breaker or fuse. Ensure wiring connections are secure.
Connected device does not turn ON/OFF at programmed times. Incorrect tripper placement or current time setting. Verify tripper positions and ensure the current time is accurately set on the dial. Check manual override switch position.
Timer motor is noisy. Normal operation for some mechanical timers. If noise is excessive or new, contact support.
Timer operates but device does not. Faulty wiring to the load or issue with the connected device. Verify load wiring. Test the connected device directly to ensure it is functional.

Nkọwapụta

Njirimara Nkọwa
Nọmba nlereanya T174
Ụdị Electromechanical ngụ oge
Ọrụ Oge awa 24
Ọnụ ọgụgụ okporo osisi 2
Ụdị kọntaktị DPST-NO (Double Pole, Single Throw - Normally Open)
Voltage AC AC 208-277V
Ampoge 40 A
Contact HP @ 120V 2 hp
Contact HP @ 240V 5 hp
Day Skipper Ee
Ụdị mkpuchi Steel, Type 1 Indoor Enclosure
Mechaa Gray Enamel
Minimum Time Setting 1 elekere
Ntọala Oge kacha awa 23
Maximum ON/OFF Cycles 12
Akụkụ (H x W x D) 7 13/16 in x 5 in x 3 in (Approximate)
Ibu Ibu 2.75 - 2.8 Pound
Included Trippers 2
UPC 078275174214
Onye nrụpụta Intermatic Incorporated

Akwụkwọ ikike na nkwado

The Intermatic T174 Time Switch comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your product or visit the official Intermatic websaịtị.

For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Intermatic customer service. You can often find support information and additional resources on the Intermatic Store on Amazon ma ọ bụ ụlọ ọrụ ha websaịtị.

Akwụkwọ ndị emetụtara - T174

Tupuview Mgbanwe Oge Nrụgharị T105 nke Oge Awa 24: Ntugharị, Waya, na Ntuziaka Ọrụ
Nduzi zuru oke maka mgbanwe oge igwe Intermatic T105 awa iri abụọ na anọ. Na-ekpuchi nkọwapụta ụdị, ịdọ aka ná ntị nchekwa, ntuziaka waya maka nhazi dị iche iche (SPNO, SPNC, SPDT), usoro mmemme, na ọrụ aka. Gụnyere tebụl zuru ezu nke ọkwa eletriki na ndụmọdụ nha waya.
Tupuview Mgbanwe Oge Nkpọ oku T103 awa iri abụọ na anọ: Ntuziaka ntinye na ọrụ
Nduzi zuru ezu maka mgbanwe oge oku Intermatic T103 awa iri abụọ na anọ, nke gụnyere nkọwapụta, ịdọ aka ná ntị nchekwa, ntuziaka waya, mmemme, na ọrụ. Dabara adaba maka ojiji n'ime ụlọ yana ike VAC 120/208/240.
Tupuview Mgbanwe Oge Elektrọmekanik nke Intermatic T170, T1400 na T1800
Nkọwa zuru oke gbasara Intermatic T170, T1400, na T1800 Series 24-Hour Electromechanical Time Switches, nke na-ekpuchi atụmatụ, nkọwapụta, ọkwa, mgbanwe ụdị, na eserese waya maka ngwa azụmahịa, ụlọ ọrụ mmepụta ihe, na ebe obibi.
Tupuview Intermatic T104 24-Hour Dial Time Switch - Specifications and Instructions
Comprehensive guide for the Intermatic T104 24-hour dial time switch, detailing its specifications, electrical ratings, safety warnings, wiring instructions, programming procedures, and operating guidelines. Includes technical data and troubleshooting tips.
Tupuview Oge ngbanwe mgbidi ime ime ime ụlọ EJ351: Nwụnye, mmemme na ntuziaka nchọpụta nsogbu
Ntuziaka zuru oke maka ịwụnye, mmemme na nchọpụta nsogbu Intermatic EJ351 Indoor Wall Switch Timer. Mụta ka esi edobe usoro ihe omume, jiri akpaaka na ụdị ntuziaka, wee dozie nsogbu ndị a na-ahụkarị.
Tupuview Intermatic Spring Wound Interval Timer Installation and Operation Guide
Detailed installation, operation, and application guide for Intermatic spring wound interval timers (FF and FD models). Includes switch ratings, wiring diagrams, and warranty information.