The Jebao Smart Doser 5.4/5.6 is an advanced, Bluetooth-enabled automatic dosing pump designed to precisely deliver liquid supplements to your saltwater or freshwater aquarium. Its programmable features, controlled via a dedicated mobile application, ensure stable water parameters and a healthy aquatic environment. Constructed with durable metal, this doser is built for reliable, long-term performance.
Ihe ngwugwu
Mgbe ebupuchara, biko chọpụta na ihe niile dị na ọ dị mma:
- Jebao Smart Doser 5.4/5.6 Unit
- Power Adapter (110-240V compatible)
- Dosing Tubes (quantity corresponding to dosing heads)
- Akwụkwọ ntuziaka
Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Nlereanya | DOSER 5.4 / DOSER 5.6 |
| Ihe onwunwe | Ọla |
| Voltage | 110-240V (DC 12V input) |
| Ike | 9W |
| Max Head (Hmax) | 1.5m |
| Max Flow Rate (Qmax) | 4*50ml/min (for 4-channel model) |
| Akụkụ (L x W x H) | 226mm x 84mm x 61mm |
| Batrị gụnyere | Mba |
| Kemịkalụ dị elu | Ọ dịghị |
| Mmalite | Mainland China |
Ntuziaka nhazi
- Mounting the Doser: Choose a suitable location near your aquarium, ensuring it is dry and easily accessible. The unit features mounting holes on the back for secure wall mounting. Use appropriate screws (not included) to fix the doser in place.
- Connect Dosing Tubes:
- Connect the intake end of each dosing tube to your liquid supplement reservoirs. Ensure the tubes reach the bottom of the reservoirs to prevent air intake.
- Connect the output end of each dosing tube to your aquarium or sump, positioning them to dispense solutions effectively without causing excessive disturbance.
- Njikọ ike: Connect the provided power adapter to the DC 12V input port on the doser unit. Plug the power adapter into a standard 110-240V electrical outlet.
- Ike izizi: Once powered, the LCD display will illuminate, showing the current time and channel indicators.
Ntuziaka ọrụ
Njikwa ngwa Bluetooth
- Budata ngwa: Chọọ maka the "Jebao Doser" or similar official app on your smartphone's app store (iOS or Android).
- Na-ejikọta:
- Gbaa mbọ hụ na agbanyere Bluetooth na ekwentị gị.
- Open the Jebao Doser app and follow the on-screen instructions to search for and pair with your Doser 5.4/5.6 unit. The doser's display may show a Bluetooth icon when connected.
- Programming Dosing Schedules:
- Within the app, you can set individual dosing schedules for each channel (C1-C4 or C1-C6 depending on model).
- Specify the dosing volume (ml), frequency (daily, weekly), and specific times for each dose.
- Save your settings to upload them to the doser unit.
- Manual Dosing/Calibration: The app typically allows for manual dosing for testing or calibration purposes. Refer to the app's interface for these functions.
Manual Control (via Unit Buttons)
The unit features several buttons for basic control and navigation:
- Arrow Buttons (Up/Down/Left/Right): Used for navigating menus and adjusting values on the LCD display.
- Enter/Confirm Button: Typically used to confirm selections or enter menu options.
- Escape/Back Button: Used to exit menus or cancel operations.
While the app offers comprehensive control, these buttons allow for basic time setting, manual pump activation, and reviewing current settings directly on the unit. Consult the included physical manual for detailed button functions.
Nlekọta
- Nhicha mgbe niile: Periodically clean the exterior of the doser unit with a soft, damp akwa . Zere iji kemịkalụ siri ike.
- Dosing Tube Inspection: Regularly check dosing tubes for kinks, blockages, or signs of wear. Replace tubes as necessary to ensure accurate dosing.
- Peristaltic Pump Head Maintenance: Over time, the tubing within the peristaltic pump heads may wear out. Refer to the detailed manual for instructions on how to inspect and replace the pump head tubing if dosing accuracy declines or leaks occur.
- Reservoir Management: Ensure your liquid supplement reservoirs are always adequately filled to prevent the pumps from running dry or drawing air.
- Nyochaa nhazi nhazi: Periodically verify the dosing accuracy of each pump using the app's calibration function or by manually measuring dispensed volumes.
Nchọpụta nsogbu
- Doser Not Powering On:
- Check if the power adapter is securely connected to both the unit and the electrical outlet.
- Gbaa mbọ hụ na ebe ọkụ eletrik ahụ na-arụ ọrụ nke ọma.
- No Dosing Occurring:
- Confirm the dosing schedule is correctly programmed and saved in the app.
- Check that liquid reservoirs contain sufficient solution.
- Inspect dosing tubes for blockages, kinks, or air bubbles.
- Ensure the pump heads are functioning correctly; listen for pump operation during scheduled doses.
- Inaccurate Dosing:
- Recalibrate the affected pump(s) using the app's calibration feature.
- Check for air leaks in the intake tubing or worn pump head tubing.
- Ensure the dosing solution is not too viscous or has not crystallized in the tubes.
- Okwu njikọ Bluetooth:
- Ensure your smartphone's Bluetooth is on and the app has necessary permissions.
- Restart the Jebao Doser unit and your smartphone.
- Move closer to the doser unit to improve signal strength.
- If issues persist, try reinstalling the app.
Ndụmọdụ Onye ọrụ
Ọnweghị ndụmọdụ onye ọrụ akọwapụtara site na nrụgharị ewepụtaraviews or Q&A. General tips for optimal performance:
- Place the doser unit above your aquarium's water level to prevent accidental siphoning.
- Use check valves on the output lines if there's a risk of back-siphoning.
- Label your dosing tubes and reservoirs clearly to avoid mixing solutions.
- Perform regular water tests to confirm the effectiveness of your dosing regimen.
Akwụkwọ ikike na nkwado