Elitech MS-4000

Ntuziaka Ntuziaka maka Ịtụle Ihe Nlele Dijitalụ Eletech MS-4000 Smart HVAC Digital Manifold

Nlereanya: MS-4000

1. Okwu mmalite

The Elitech MS-4000 is an advanced 4-way digital manifold gauge designed for HVAC professionals. It integrates multiple HVAC tools into a single unit, providing precise measurements for pressure, temperature, and vacuum. This device features a smart touch screen, real-time monitoring via an app, OTA firmware updates, intelligent vacuum leakage judgment, offline data recording, and temperature compensation for accurate tightness testing. It supports 88 different refrigerants and offers automatic calculation of superheating and subcooling temperatures.

Elitech MS-4000 Smart HVAC Digital Manifold Gauge in its carrying case with hoses

Figure 1: Elitech MS-4000 Digital Manifold Gauge with accessories in carrying case.

2. Nhazi

2.1 Unboxing na njirimara akụrụngwa

Carefully unpack the Elitech MS-4000 from its packaging. Verify that all components are present and undamaged. The standard package includes the MS-4000 manifold unit, charging hoses (red, blue, yellow), temperature clamps, and a performance report.

Video 1: Unboxing the Elitech MS-4000 Digital Manifold Gauge and its components.

2.2 Battery Installation and Power On

The MS-4000 is powered by a Type-C charging port and has a battery capacity of 20 hours. For initial use or after long storage, ensure the device is charged. If using AA batteries (for models like MS-1000, though MS-4000 uses Type-C charging), install 3 AA batteries into the designated compartment. To power on, press and hold the power button until the screen illuminates.

Elitech MS-4000 display showing battery removal instructions

Figure 2: Display showing battery removal for storage (relevant for some models).

2.3 Ngwa nwụnye na njikọ

Download the Elitech Tools App from your device's app store (iOS and Android compatible). Follow the in-app instructions to connect your MS-4000 manifold gauge via Bluetooth for real-time monitoring, OTA firmware updates, and data management.

Elitech MS-4000 showing real-time monitoring and app connectivity

Figure 3: Real-time monitoring and OTA firmware updates via the Elitech Tools App.

3. Ntuziaka ọrụ

3.1 General Operation and Touch Screen Interface

The MS-4000 features a 5-inch touch screen for intuitive navigation. The interface displays vacuum, pressure, and temperature data clearly. Use the touch screen to select functions and adjust settings.

Elitech MS-4000 with features like APP Monitoring, Intelligent Vacuum Leakage Judgment, Offline Data Recording, Temperature Compensation, and 5 inch Touch Screen

Figure 4: Key features of the Elitech MS-4000, including the 5-inch touch screen.

3.2 Nrụgide na nha okpomọkụ

Connect the appropriate hoses to the 4-way valve and the HVAC system. The device will display pressure and temperature readings in real-time. The MS-4000 automatically measures superheating and subcooling temperatures for 88 different refrigerants. Frequently used refrigerants can be saved for quick access.

3.3 Ntụle oghere

The MS-4000 includes a micron gauge transmitter for precise vacuum measurements. Connect the vacuum pump and monitor the vacuum levels directly on the screen. The range for vacuum measurement is 0-19000 micron.

3.4 System Leakage Testing with Temperature Compensation

The device allows for precise monitoring of pressure holding and vacuum leakage tests. It features temperature compensation settings to minimize the influence of temperature variations on the accuracy of tightness testing results. Adjust allowable percentage and duration settings as needed.

Elitech MS-4000 display showing temperature compensation settings for tightness testing

Figure 5: Temperature compensation settings for accurate tightness testing.

3.5 Data Recording and Export

The MS-4000 can record up to 100,000 points of offline data. This data can be easily exported to a computer via a USB port for further analysis of temperature, pressure, and vacuum values.

3.6 Auto Off Time Settings

The device has an adjustable auto-off feature to conserve battery life. Default auto-off is set to 15 minutes, but options like 5, 10, 15, 30, and 60 minutes are selectable.

4. Nlekọta

4.1 Nlekọta n'ozuzu

Keep the manifold gauge clean and free from dust and debris. Store it in its protective carrying case when not in use to prevent damage. Avoid exposing the device to extreme temperatures or moisture.

4.2 Njikwa batrị

For long-term storage, it is recommended to fully charge the device and then store it in a cool, dry place. If the device uses removable batteries (like 3 AA batteries in some models), remove them if the unit will not be used for an extended period to prevent leakage.

5. Nchọpụta nsogbu

5.1 Ngwaọrụ anaghị agba ọkụ

  • Ensure the device is fully charged via the Type-C port.
  • If applicable, check that batteries are correctly installed and not depleted.

5.2 Nsogbu Njikọ Ngwa

  • Gbaa mbọ hụ na agbanyere Bluetooth na ngwaọrụ mkpanaka gị.
  • Verify the Elitech Tools App is updated to the latest version.
  • Restart both the manifold gauge and your mobile device.
  • Ensure the manifold gauge is within Bluetooth range of your mobile device.

5.3 Ọgụgụ na-ezighi ezi

  • Lelee njikọ ọsụsọ niile maka ntapu.
  • Ensure temperature clamps are securely attached to the pipes.
  • Verify the correct refrigerant type is selected in the device settings.
  • Perform a calibration check if available in the device menu or app.

6. Nkọwapụta

6.1 Nkọwa n'ozuzu

IheUru
Aha ikaElitech
Nọmba nlereanyaMS-4000
Aha ngwaahịaIgwe nrụgide dijitalụ
NgwaHydraulic Industries, Air Conditioning Fitting
Njikọ1/4" SAE*3 and 3/8" SAET*1
Igwe nju oyiR134A, R410A, R22A, R404A (and 84 other refrigerants)
AgbaOrange/Oji
Connection MaterialBrass Thread
ỤdịGas Pressure Manometer
Ibu7KG (Product package weight is 30kg)
Ịnye ọkụỤdị-C Nchaji
Ike batrịawa 20
Ike ịdekọ100,000 isi
Valves4
Oke nrụgide-14.5 ~ 800 psi
Izi ezi0.5% FS
Mkpebi0.5 psi
Port4
Ihuenyo mmetụ akaEe

6.2 Okpomọkụ Clamp Oke

IheUru
Oke-40 ~ 150℃ / -40 ~ 300℉
Izi ezi± 0.1 ℃ / ± 0.18 ℉
Mkpebi0.1℃ / ℉

6.3 Vacuum Parameters

IheUru
Oke0-19000 micron
Accuracy (0-10000 micron)10% of Reading ± 10 micron
Accuracy (10000-19000 micron)20% nke Ọgụgụ

6.4 Supported Refrigerants

R113, R114, R115, R116, R12, R123, R1233ZD, R1234ZE, R1234YF, R124, R125, R13, R134a, R14, R141B, R142B, R143A, R152A, R170, R22, R23, R236FA, R245FA, R290, R32, R401A, R401B, R401C, R402A, R402B, R403B, R404A, R406A, R407A, R407B, R407C, R407D, R407F, R408A, R409A, R410A, R410B, R412A, R413A, R414A, R414B, R416A, R417A, R417C, R420A, R421A, R421B, R422A, R422B, R422C, R422D, R424A, R426A, R427A, R428A, R429A, R434A, R437A, R438A, R441A, R443A, R448A, R449A, R450A, R452A, R452B, R453A, R454A, R454B, R455A, R458A, R500, R502, R503, R507A, R508A, R508B, R514A, R600, R600a, R601a, R718, R744.

7. Ndụmọdụ onye ọrụ

  • Utilize the Elitech Tools App for enhanced functionality, including remote monitoring and data analysis, to streamline your workflow.
  • Were advantage of the temperature compensation feature during leakage tests to ensure the most accurate results, especially in environments with fluctuating temperatures.
  • Regularly export recorded data via USB to keep a comprehensive log of your work and for detailed analysis.
  • Customize the auto-off time setting to balance battery life and convenience based on your typical usage patterns.
  • Keep the 4-way valve and hoses clean and properly sealed to prevent refrigerant cross-contamination and ensure accurate readings.

8. Akwụkwọ ikike na nkwado

8.1 Akwụkwọ ikike ngwaahịa

The Elitech MS-4000 Smart HVAC Digital Manifold Gauge comes with a 3-year warranty. This warranty covers manufacturing defects and ensures free spare parts for covered issues. Please retain your proof of purchase for warranty claims.

8.2 Nkwado nka na ụzụ

For technical assistance, troubleshooting, or service inquiries, please contact Elitech customer support. Refer to the official Elitech websaịtị ma ọ bụ nkwakọ ngwaahịa maka ozi kọntaktị kachasị ugbu a.


Ngwuputa na ọdịnaya nke Elitech MS-4000 Smart Digital HVAC Manifold Gaugeview

Ngwuputa na ọdịnaya nke Elitech MS-4000 Smart Digital HVAC Manifold Gaugeview

0:41 • 1280×720 • unboxing

Akwụkwọ ndị emetụtara - MS-4000

Tupuview Ntuziaka na nkọwapụta nke Elitech MS-800 Series Digital Manifold Gauge
Akwụkwọ ntuziaka zuru oke maka ngwa Elitech MS-800 Series dijitalụ, nke gụnyere okwu mmalite ngwaahịa, ntuziaka nchekwa, nchekwa gburugburu ebe obibi, nkọwapụta zuru ezu, na ntuziaka ọrụ ngwa ngwa maka nha nrụgide na okpomọkụ, ule njide nrụgide, na chaja refrigerant maka HVAC na sistemụ refrigerant.
Tupuview Ntuziaka Onye Ọrụ Elitech MS Series Digital Manifold Gauge
Akwụkwọ ntuziaka maka Elitech MS Series dijitalụ manifold gauge, nke na-ekpuchi nkọwa ngwaahịa, n'ozuzu yaview, ọrụ bọtịnụ, nkọwapụta, ntuziaka mmalite ngwa ngwa, usoro ọrụ, ngwa nwere ọgụgụ isi, na mmezi.
Tupuview Ntuziaka Onye Ọrụ Elitech MS-100 PLUS Smart Digital Manifold Gauge
Akwụkwọ ntuziaka zuru oke maka Elitech MS-100 PLUS Smart Digital Manifold Gauge, nke gụnyere okwu mmalite ngwaahịa, ntuziaka nchekwa, na ihe ndị ọzọ.view, ọrụ bọtịnụ, paramita teknụzụ, na ntuziaka ọrụ ngwa ngwa maka sistemụ friji na HVAC.
Tupuview Akwụkwọ ntuziaka onye ọrụ Elitech MS-100 Digital Manifold Gauge
Akwụkwọ ntuziaka maka Elitech MS-100 Digital Manifold Gauge, na-akọwa atụmatụ ya, ọrụ ya, nkọwapụta ya, na mmezi ya.
Tupuview Elitech MS-100 Digital Manifold Gauge: Atụmatụ, Ọrụ, na Nkọwapụta
Nduzi zuru oke maka Elitech MS-100 Digital Manifold Gauge, nke na-ekpuchi atụmatụ ya, ọrụ ngwa ngwa, nkọwapụta teknụzụ, ihe mgbochi, na nkọwapụta ngwaahịa maka sistemụ HVAC na friji.
Tupuview Elitech MS-100 Digital Manifold: Akwụkwọ ntuziaka onye ọrụ na nkọwapụta
Ntuziaka zuru oke na Elitech MS-100 dijitalụ manifold, na-ekpuchi atụmatụ ya, nkọwa nka, ọrụ, ntuziaka nchekwa, na nchọpụta nsogbu. Mụta ka esi eji ngwaọrụ maka nrụgide na nha ọnọdụ okpomọkụ, ule ntanaka, usoro agụụ, na ntinye data site na iji ngwa Elitech Tools.