DAB 60231855

DAB Evosta 2 40-70/130 Circulator Pump Instruction Manual

Model: 60231855 | Brand: DAB

1. Okwu mmalite na gafereview

The DAB Evosta 2 is an electronic, low-energy consumption circulator pump designed for water circulation in various domestic heating and air conditioning systems. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Evosta 2 pump.

The Evosta 2 series combines the robustness of mechanical circulators with the advantages of electronic control. It features a synchronous permanent magnet motor, a frequency converter, and an efficiency index (EEI) of ≤ 0.18, ensuring high efficiency and reliability. Its compact design and comprehensive performance make it suitable for replacing older three-speed circulators.

DAB Evosta 2 Circulator Pump
Figure 1: DAB Evosta 2 Circulator Pump. This image shows the main unit with its green and black housing, control panel, and threaded connections.

2. Ozi nchekwa

Ihe dị mkpa: Read all safety instructions before installation or operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Naanị ndị ọrụ ruru eru ga-arụrịrị nrụnye na nrụzi.
  • Ensure the power supply is disconnected before performing any work on the pump.
  • The pump operates with hot liquids; allow it to cool before handling to prevent burns.
  • Protect the pump from moisture and direct water spray.
  • Do not operate the pump if it is damaged or if the electrical cable is frayed.
  • The pump is designed for clean, non-viscous, chemically neutral liquids. Do not use with flammable or corrosive liquids.

3. Nkọwa ngwaahịa na atụmatụ

The Evosta 2 circulator pump is engineered for optimal performance and durability. Key features include:

  • Ike ike: Equipped with a synchronous permanent magnet motor and frequency converter, achieving an EEI ≤ 0.18.
  • Nrụpụta siri ike: Cast iron pump body with cataphoresis treatment, wet rotor motor, and ceramic shaft mounted on ceramic bushings lubricated by the pumped liquid.
  • Integrated Protection: Internal motor protection eliminates the need for external overload protection.
  • Njikwa Enyi na Enyi: A single sequential adjustment button on the control panel simplifies settings.
  • Ịnweta nlekọta: Direct access to the crankshaft for potential unlocking.
  • High Protection Rating: IPX5 ogo nchedo.
DAB Evosta 2 Features and Benefits
Nyocha 2: N'eluview of Evosta 2 features, highlighting its energy efficiency (EEI ≤ 0.18) and 5-year warranty. The image also shows different models in the Evosta series.

The pump casing is made of steel, with a technopolymer impeller. The rotor sleeve, stator sleeve, and closing flange are stainless steel. The thrust ring is graphite, and the sealing rings are EPDM. An air bleed plug made of brass is integrated.

DAB Evosta 2 Exploded View and Materials List
Ọgụgụ 3: gbawara view of the Evosta 2 pump with a corresponding list of materials for each component, illustrating the internal construction.

4. Nwụnye

Proper installation is crucial for the pump's performance and longevity. Follow these guidelines:

  • Ọnọdụ nkwụnye: Install the pump with the motor axis horizontal.
  • Njikọ ọkpọkọ: The Evosta 2 40-70/130 is equipped with 1" (G 1") threaded connections. The 1/2" designation refers to the thread intended for connection to 1" to 1/2" reduced female fittings. Verify compatibility with your existing pipes or fittings.
  • Ịnye ọkụ: Connect the pump to a single-phase 1 x 230 V ~ 50/60 Hz power supply. Ensure the electrical installation complies with local regulations.
  • Sistemu na-efe efe: Before starting the pump, ensure the system is thoroughly flushed to remove any debris that could damage the pump.
  • Nchacha ikuku: The pump includes an integrated air bleed plug. After filling the system, open the plug to release any trapped air.

Refer to the dimensional drawings for precise measurements and connection details to ensure proper fitment within your system.

DAB Evosta 2 Dimensional Drawing
Figure 4: Dimensional drawing of the Evosta 2 40-70/130 pump, showing key measurements (in mm) and pump connection details (1" G thread).

5. Ọrụ

The Evosta 2 pump features a control panel on the electronic control device cover, allowing for easy adjustment of its functions. The pump offers nine setting options, selectable via the MODE button.

  • Nhọrọ ntọala: Press the MODE button to cycle through the available settings. The selected setting is indicated by six illuminated segments on the display.
  • Ụdị arụ ọrụ: The pump supports various operating modes, typically including proportional pressure, constant pressure, and constant curve modes, to adapt to different system requirements.
DAB Evosta 2 Operating Modes and Settings
Figure 5: Diagram illustrating the different operating modes (Proportional Pressure, Constant Pressure, Constant Curve) and an example of model designation for the Evosta series.

Consult the specific icons or indicators on your pump's control panel to identify the active operating mode and adjust as needed for your heating or cooling system.

6. Nlekọta

Regular maintenance ensures the long-term reliability and efficiency of your Evosta 2 pump.

  • Nchacha ikuku: Periodically check and, if necessary, open the integrated brass air bleed plug to release any air trapped in the pump. This prevents cavitation and ensures smooth operation.
  • Crankshaft Unlocking: In case of a blockage, the pump provides direct access to the crankshaft for manual unlocking. Refer to the technical diagrams for the exact location.
  • Nhicha: Keep the exterior of the pump clean and free from dust and debris. Do not use abrasive cleaners.
  • System Fluid: Ensure the pumped liquid remains clean and free of solid substances and mineral oils. Glycol content should not exceed 30%.
  • No Overload Protection Needed: Due to internal motor protection, no external overload protection is required.

7. Nchọpụta nsogbu

If you encounter issues with your Evosta 2 pump, consider the following common problems and solutions:

  • Mgbapu anaghị amalite:
    • Lelee ọkụ ọkụ na ihe mgbawa sekit.
    • Ensure the pump is properly connected to the electrical mains.
    • Verify that the motor is not seized. Use the direct access to the crankshaft to attempt manual unlocking if necessary.
  • No Flow or Reduced Flow:
    • Check for air in the system. Bleed air using the integrated plug.
    • Inspect for blockages in the pipes or pump impeller.
    • Ensure valves in the system are open.
    • Verify the selected operating mode and setting are appropriate for the system's requirements.
  • Mkpọtụ na-adịghị ahụkebe:
    • Noise can indicate air in the system. Purge air.
    • Check for foreign objects in the pump.
    • Ensure the pump is securely mounted and not vibrating excessively.

If problems persist after attempting these solutions, contact qualified service personnel or DAB customer support.

8. Nka na ụzụ nkọwa

OkeUru
NlereanyaEvosta 2 40-70/130
Nọmba nke onye nrụpụta60231855
Oke arụ ọrụ0.4 – 3.6 m³/h with head up to 6.9 meters
Oke okpomọkụ Liquid0 Celsius C ruo +110 Celsius
Nrụgide arụ ọrụ10 mmanya (1000kPa)
Ndekọ nchekwaIPX5
Klas mkpuchiF
NwụnyeMotor axis horizontal
Ịnye ọkụ1 x 230 V ~ 50/60 Hz
Pumped LiquidClean, free of solids/mineral oils, non-viscous, chemically neutral, water-like (max 30% glycol)
Ihe eji arụ ọrụ mgbapụtaNkedo ígwè na ọgwụgwọ cataphoresis
moto Casing iheIgwe igwe
Impeller iheTechnopolymer
Ihe eji eme iheCeramic
Ibu1.86 n'arọ
Akụkụ ngwugwu15 x 14 x 10 cm
DAB Evosta 2 Performance Curves and Data Table
Figure 6: Performance curves and detailed technical data table for various Evosta 2 models, including flow rate (Q) and head (H) values.

9. Akwụkwọ ikike na nkwado

The DAB Evosta 2 circulator pump comes with a 5-afọ akwụkwọ ikike, ensuring peace of mind regarding its quality and durability. This warranty covers manufacturing defects under normal use conditions.

For technical assistance, warranty claims, or spare parts inquiries, please contact your authorized DAB dealer or customer support. When contacting support, please have your model number (60231855) and purchase date available.

Information regarding the availability of spare parts is not provided in the product data. Please consult your dealer for specific spare part availability.

Ask a question about this manual