Kanlux 36632
Kanlux ZEPO Cabinet Luminaire User Manual
Ụdị: 36632
1. Okwu mmalite
Thank you for choosing the Kanlux ZEPO Cabinet Luminaire. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new lighting fixture. Please read this manual thoroughly before installation and keep it for future reference.
The Kanlux ZEPO luminaire is designed for installation under cabinets, such as kitchen worktops, providing elegant and functional accent lighting. Its compact design and various color options (black, white, silver/chrome) allow it to seamlessly integrate into various interior styles.

Ọgụgụ 1: Ọpụample of Kanlux ZEPO luminaire installed in a kitchen setting, illuminating a countertop.
2. Ozi nchekwa
Na-edebe nchekwa nchekwa ndị a mgbe niile iji gbochie mmerụ ahụ ma ọ bụ mmebi:
- Hụ na ewepụla ọkụ eletrik tupu agbanye ya, emezi ya, ma ọ bụ dochie bọlbụ ahụ.
- This luminaire is rated Class III, meaning it requires a safety extra-low voltage (SELV) power supply. Do not connect directly to mains voltage without an appropriate transformer.
- The luminaire has an IP20 rating, indicating protection against solid objects larger than 12.5mm. It is not protected against water. Install only in dry, indoor environments.
- Do not cover the luminaire with insulating material.
- Use only G4 bulbs with a maximum power of 10W.
- Ekwesịrị ịrụ nrụnye site n'aka onye ọrụ ọkụ eletrik ma ọ bụrụ na ị maghị ya.
- Debe ebe ụmụaka na-apụghị iru.
3. Ntọala na nwụnye
Follow these steps for proper installation of your Kanlux ZEPO luminaire:
- Kwadebe Mpaghara Nwụnye: Choose a suitable location under a cabinet or shelf. Ensure there is enough space for the luminaire and access for wiring.
- Kaa akara ebe mgbago: Use the luminaire as a template to mark the screw holes on the underside of the cabinet. The luminaire has a triangular shape with sides of approximately 130mm.
- Oghere pilot: Carefully drill small pilot holes at the marked points.
- Secure the Luminaire: Attach the luminaire to the cabinet using appropriate screws (not included).
- Jikọọ Wiring: Connect the luminaire to a compatible Class III (SELV) power supply. Ensure all connections are secure and insulated. Refer to your power supply's instructions for specific wiring details.
- Fanye bọlbụ: Gently insert a G4 bulb (max 10W) into the luminaire's socket.
- Nwalee: Weghachite ike ma nwalee ọkụ.

Figure 2: Technical diagram showing the dimensions of the Kanlux ZEPO luminaire (130mm x 130mm x 40mm depth).

Ọgụgụ 3: nso nso view of the Kanlux ZEPO luminaire, showing the G4 bulb socket and integrated power switch.
4. Ntuziaka ọrụ
The Kanlux ZEPO luminaire is designed for simple operation:
- Gbanyụọ/ Gbanyụọ: If your luminaire model includes an integrated switch (as shown in Figure 3), use it to turn the light on or off. Otherwise, control the luminaire via the external switch connected to your power supply.
- Ndokwa bọlbụ: To replace the G4 bulb, first disconnect the power supply. Carefully remove the old bulb and insert the new G4 bulb into the socket. Ensure the bulb is securely seated before restoring power.
5. Nlekọta
To ensure the longevity and optimal performance of your luminaire:
- Nhicha: Disconnect power before cleaning. Wipe the luminaire with a soft, dry cloth. Do not use abrasive cleaners or solvents, as they may damage the finish.
- Nyocha: Periodically check the wiring and connections for any signs of wear or damage.
- Ụdị bọlbụ: Always use the specified G4 bulb type with a maximum power of 10W. Using higher wattage bulbs can cause overheating and damage.
6. Nchọpụta nsogbu
If you encounter issues with your luminaire, try the following:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Ìhè anaghị agbanwuo. | No power supply, faulty bulb, loose connection, faulty switch. | Check power source. Replace bulb. Check all wiring connections. Test the switch. |
| Ìhè flickers. | Loose bulb, unstable power supply, incompatible bulb. | Ensure bulb is seated correctly. Check power supply stability. Use a compatible G4 bulb. |
| Luminaire gets too hot. | bọlbụ wat na-ezighi ezitage (oke elu). | Ensure you are using a G4 bulb with a maximum of 10W. |
If the problem persists after attempting these solutions, please contact Kanlux customer support or a qualified electrician.
7. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Ụdị | Kanlux |
| Nọmba nlereanya | 36632 |
| Ike | 10 watts Max |
| Ụdị okpu | G4 |
| Protection Index (IP) | IP20 |
| Klas eletrik | Klas III |
| Ihe onwunwe | Alloy Steel |
| Ụdị | Oge a |
| Ibu Ibu | 140 grams |
| Akụkụ (ihe dị ka.) | 130mm (Length) x 130mm (Width) x 40mm (Depth) |
| Batrị achọrọ | Mba |
8. Akwụkwọ ikike na nkwado
Kanlux products are manufactured to high quality standards. For information regarding warranty terms and conditions, please refer to the warranty card included with your product or visit the official Kanlux website. For technical support or inquiries, please contact Kanlux customer service through their official channels.