This user manual provides detailed instructions for the safe and efficient installation, operation, and maintenance of the Knightsbridge M6300 Metal Clad 13A Switched Spur Unit. Please read this manual thoroughly before installation and retain it for future reference.

The M6300 is a heavy-duty metal clad switched fused spur unit designed for robust electrical installations. Key features include:

2. Ozi nchekwa

WARNING: Electrical installations should only be carried out by a qualified electrician in accordance with current wiring regulations (e.g., BS 7671 in the UK).

3. Ihe ngwugwu

Nyochaa na akụrụngwa niile dị na adịghị emebi emebi mgbe ebupụ ya:

Knightsbridge M6300 Metal Clad 13A Switched Spur Unit

Foto 3.1: N'ihu view of the Knightsbridge M6300 Metal Clad 13A Switched Spur Unit. The unit features a robust silver metal casing, a white rocker switch on the right, and a fuse holder on the left, clearly marked "FUSE".

4. Nwụnye

The M6300 unit is designed for fixed wiring installations. Follow these steps carefully:

  1. Nkwadebe: Ensure the mains electricity supply to the circuit where the unit will be installed is completely isolated at the consumer unit/fuse board. Use a suitable voltage tester iji gosi na sekit anwụọla.
  2. Ịkwanye:
    • The unit comes with an integrated back box. Mark the desired mounting position on the wall.
    • Drill appropriate holes for the mounting screws.
    • Secure the back box to the wall using suitable screws and wall plugs.
  3. Wiring:
    • Carefully strip the insulation from the circuit cables (Live, Neutral, Earth) to the appropriate length for the terminals.
    • Connect the incoming Live (brown or red) cable to the "L IN" terminal.
    • Connect the incoming Neutral (blue or black) cable to the "N IN" terminal.
    • Connect the incoming Earth (green/yellow) cable to the "E" terminal.
    • Connect the outgoing Live (brown or red) cable to the "L OUT" terminal.
    • Connect the outgoing Neutral (blue or black) cable to the "N OUT" terminal.
    • Ensure all terminal screws are tightened securely to prevent loose connections.
  4. Na-agbakọ: Insert a 13A fuse into the fuse holder. Ensure the fuse is correctly seated.
  5. Mgbakọ ikpeazụ: Carefully position the front plate onto the back box, ensuring no wires are trapped. Secure the front plate with the provided screws.
  6. Nnwale: Once installation is complete, restore the mains electricity supply and test the unit's functionality.

5. Ọrụ

The Knightsbridge M6300 is a simple ON-OFF switched spur unit. Its operation is straightforward:

6. Nlekọta

The M6300 unit requires minimal maintenance. Follow these guidelines to ensure its longevity and safe operation:

7. Nchọpụta nsogbu

If you encounter issues with your M6300 unit, refer to the following common problems and solutions:

NsogbuIhe nwere ike imeNgwọta
No power to connected appliance.
  • Unit switch is OFF.
  • Fọpụ gbawara agbawa.
  • Njikọ wiwi adịghị agwụ agwụ.
  • Akwụsịla sekit sekit.
  • Switch unit ON.
  • Replace 13A fuse (ensure power is off first).
  • Isolate power and check wiring connections (consult electrician).
  • Reset circuit breaker at consumer unit.
Unit feels warm.
  • Ibu ibu gabiga ókè na sekit.
  • Njikọ rụrụ arụ.
  • Reduce load or check appliance.
  • Isolate power and check wiring connections (consult electrician).
Switch is stiff or not operating smoothly.
  • Okwu gbasara usoro.
  • irighiri ihe.
  • Do not force. Unit may need replacement.
  • Clean around switch (ensure power is off).

If the problem persists after attempting these solutions, please contact a qualified electrician or Knightsbridge customer support.

8. Nkọwapụta

Technical specifications for the Knightsbridge M6300 Metal Clad 13A Switched Spur Unit:

Knightsbridge M6300 Data Sheet

Figure 8.1: Data sheet for Knightsbridge Metalclad 13A fused spur units, including the M6300 model. This sheet provides detailed technical specifications and dimensions for various models in the series.

NkọwapụtaUru
Nọmba nlereanyaM6300
ỤdịKnightsbridge
Ogo dị ugbu a13 Amps
Nrụ ọrụ Voltage230 volts
Ụdị ọrụON-Gbanyụọ
Ụdị kọntaktịNa-emepe emepe
Ụdị njikọClamp
Ụdị njedebeỊghasa
Circuit .dị1-ụzọ
Ụdị ActuatorPịa bọtịnụ
Ngwa kọntaktịỌla
Ọkwa Nchedo Mba Nile (IP)IP33
Ọnụọgụ nke ọkwa1
Usoro njikwaMetụ aka
Wattage2990 watts (2.99E+3)
Akụkụ ngwaahịa (L x W x H)3.21 x 1.93 x 32.09 sentimita asatọ
Ibu Ibu7.4 ounces
Ihe onwunweỌla
AsambodoBS 1363-4
Akwụkwọ ikike ọkọlọtọ1 year (as per datasheet)

9. Akwụkwọ ikike na nkwado

The Knightsbridge M6300 Metal Clad 13A Switched Spur Unit is manufactured to high standards and is certified to BS 1363-4. Based on the provided data sheet, a standard warranty of 1 afọ is typically offered.

For technical support, warranty claims, or further assistance, please contact Knightsbridge customer service or refer to their official website. Ensure you have your product model number (M6300) and purchase details available when contacting support.

Onye nrụpụta: Knightsbridge

Websaịtị: www.milicaraland.co.uk (ML Accessories is the parent company of Knightsbridge)

Akwụkwọ ndị emetụtara - M6300

Tupuview Knightsbridge Electrical Accessories Installation Guide and Product Information
Comprehensive guide to installing and using Knightsbridge electrical accessories, including sockets, switches, USB chargers, dimmers, and Bluetooth speaker products. Features safety information, wiring diagrams, and warranty details.
Tupuview Knightsbridge Electrical Accessories: Installation Guide and Safety Information
Comprehensive installation guide and safety information for Knightsbridge electrical accessories, including sockets, switches, dimmers, and USB charging outlets. Covers wiring diagrams, safety warnings, product specifications, and warranty details.
Tupuview Knightsbridge Electrical Accessories Installation and Safety Guide
Comprehensive guide for installing and safely using Knightsbridge electrical accessories, including sockets with USB chargers and Bluetooth speakers. Covers wiring, safety precautions, and warranty information.
Tupuview Knightsbridge Electrical Accessories Installation and Safety Guide
Comprehensive guide to the safe installation and operation of Knightsbridge electrical accessories, including sockets, USB chargers, dimmers, and switches. Covers wiring, safety precautions, and product specifications.
Tupuview Knightsbridge 2023 Lighting & Wiring Ngwa katalọgụ
Explore the comprehensive 2023 catalogue from Knightsbridge, featuring a wide range of lighting and wiring accessories, including switches, sockets, USB chargers, and smart home solutions. Discover quality products for domestic and commercial applications.
Tupuview Knightsbridge SKR008 / SKR009A Installation and Maintenance Manual
Detailed installation and maintenance guide for Knightsbridge SKR008 and SKR009A electrical sockets. Includes safety precautions, step-by-step installation instructions, wiring diagrams, and warranty information.