WLLKIY 1005003990425887

WLLKIY Hybrid Solar Inverter User Manual

Models: SMG-II-3.6KW-24V-WIFI, SMG-II-5.6KW-48V-WIFI, SMX-II-3.6KW-24V, SMX-II-5.6KW-48V

1. Okwu mmalite

This manual provides essential information for the installation, operation, and maintenance of your WLLKIY Hybrid Solar Inverter. Please read this manual thoroughly before installation and operation to ensure proper functioning and safety. Keep this manual for future reference.

The WLLKIY Hybrid Solar Inverter is a versatile power solution designed to integrate solar power, utility grid power, and battery power to provide continuous power supply. It features a pure sine wave output, high PV input voltage range, and a built-in MPPT solar charge controller, making it suitable for various off-grid and hybrid solar applications.

2. Ngwaahịa gafereview

The WLLKIY Hybrid Solar Inverter is a multi-functional inverter/charger, combining functions of an inverter, solar charger, and battery charger to offer uninterruptible power support with a portable size. Its comprehensive LCD display allows user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage dabere na ngwa dị iche iche.

  • Igwe ntụgharị anyanwụ dị ọcha.
  • Ntinye PV dị elu voltage nso (120V-450V).
  • Built-in MPPT solar charge controller.
  • The inverter can run without a battery (PV voltage must be above 250V).
  • Built-in dust protection for remote monitoring in harsh environments.
N'ihu view of the WLLKIY Hybrid Solar Inverter

Foto 2.1: N'ihu view of the WLLKIY Hybrid Solar Inverter, showing the display panel and ventilation grilles.

WLLKIY Hybrid Solar Inverter with key specifications highlighted

Figure 2.2: The inverter highlighting key specifications such as 3.6KW/24V, 100A Max Solar Charge Current, 4000W Max PV Array Power, 500VDC Max PV Array Voltage, and Built-in MPPT Solar Controller.

3. Ntuziaka nchekwa

Please observe all warnings and cautions in this manual. Improper operation may cause damage to the unit and/or personal injury. This device is intended for indoor use only. Do not expose it to rain, snow, or any type of liquid.

  • Akwa Voltage Ịdọ aka na ntị: The inverter operates with high voltages. All wiring must be performed by qualified personnel.
  • Nchekwa batrị: Batteries can produce explosive gases. Ensure proper ventilation when working with batteries. Do not short-circuit battery terminals.
  • Nda ala: The inverter must be properly grounded to prevent electric shock.
  • Igwe ikuku: Ensure adequate airflow around the inverter to prevent overheating. Do not block ventilation openings.
  • Nlekọta: This product should be used under the direct supervision of an adult.
Multilingual warning label for adult supervision

Figure 3.1: A multilingual warning label indicating that the product is to be used under the direct supervision of an adult.

4. Ntọala & nwụnye

Before installation, ensure all components are present and undamaged. Choose a suitable mounting location that is dry, well-ventilated, and away from flammable materials. The inverter should be mounted vertically.

4.1 Eserese Njikọ Sistemụ

Diagram showing connections for solar panels, generator, utility grid, battery packs, and various loads to the hybrid solar inverter

Figure 4.1: A comprehensive system connection diagram illustrating how solar panels, a generator, the utility grid, and battery packs connect to the hybrid solar inverter, which then supplies power to various household and office loads.

4.2 Njikọ njikọ

Refer to the back panel of the inverter for connection terminals. Ensure all connections are secure and correctly polarized.

Back panel of the WLLKIY Hybrid Solar Inverter showing AC input, AC output, PV input, RS232, USB, battery terminals, and circuit breaker

Figure 4.2: The back panel of the inverter, detailing connection points for AC input (AC IN), AC output (AC OUT), PV input (PV IN), RS232, USB, battery positive (POS) and negative (NEG) terminals, and the input breaker.

  • Njikọ batrị: Connect the battery bank to the 'BATTERY POS' and 'BATTERY NEG' terminals. Ensure correct polarity.
  • Njikọ ntinye AC: Connect the utility grid or generator AC supply to the 'AC IN' terminal.
  • Njikọ Mbupụ AC: Connect your loads (appliances, computers, etc.) to the 'AC OUT' terminal.
  • Njikọ Ntinye PV: Connect your solar panel array to the 'PV IN' terminals. Observe correct polarity and voltage ókè.
  • Ọdụ ụgbọ mmiri nkwukọrịta: Use the RS232 or USB ports for monitoring and configuration with compatible software.

5. Ụdị arụ ọrụ

The inverter supports various operating modes, which can be configured via the LCD display. These modes determine the power source priority (utility, solar, or battery) for supplying power to the loads and charging the batteries.

Diagram illustrating different operating modes of the inverter display

Figure 5.1: Display illustrations showing four operating modes: 1. With battery, solar and AC available. 2. With battery, solar and AC not available. 3. Without battery, solar available. 4. Without battery, AC available. This image also shows a 'Pure Sine Wave 50/60 Hz Auto Detection' graphic.

  • Utility Priority Mode: The inverter primarily uses utility power to supply loads and charge batteries. Solar power is used when utility power is unavailable or insufficient.
  • Solar Priority Mode: Solar power is the primary source for loads and battery charging. Utility power is used only when solar power is insufficient or unavailable.
  • Ụdị mkpa batrị: The inverter uses battery power as the primary source. Utility or solar power is used to charge batteries or when battery voltage di ala.
  • Enweghị Ụdị batrị: Certain models can operate without a battery, directly converting solar PV power to AC for loads, provided the PV voltage dị n'elu 250V.

6. Nkọwapụta

The following table provides detailed technical specifications for the WLLKIY Hybrid Solar Inverter models.

NjirimaraSMG II 3.6KWSMG II 5.6KPSMX-II-3.6KWSMX-II-5.6KP
Ike3.6KVA / 3.6KW5.6KVA / 5.6KW3.6KVA / 3.6KW5.6KVA / 5.6KW
Parallel AbilityMbaYES, 1-9pcsMbaYES, 1-6pcs
Voltage Oke170-280VAC (for personal computers); 90-280VAC (for home appliances)
Ugboro ugboro50/60Hz (Nchọpụta akpaaka)
Ike ịwa ahụ7000VA11000VA6000VA10000VA
Ụdị ebili mmiriOkpokoro nke Sine
Oge mbufe10 Ms (for personal computer); 20 Ms (for home appliances)
Peak Efficiency (PV to INV)96%> 95%96%> 95%
Peak Efficiency (Battery to INV)93%> 92%93%> 90%
Nchekwa oke ibu5s@>=150%load; 10s@110%-150%load; Alarm and turn off charging after 1 minute
Ihe kpatara ike1
Volt batrị24VDC48VDC24VDC48VDC
Nchaji float Voltage27VDC54VDC27.6VDC55.2VDC
Nchekwa oke ụgwọ33VDC63VDC30VDC60VDC
Ụdị chaja anyanwụMPPT
Max PV Array ike4000W5500W4000W6000W
Max PV Array Open Circuit Voltage500VDC
PV Array MPPT Voltage Oke120VDC - 450VDC
Max Solar Input Current15A18A15A18A
Max Solar Charging Current100A80A100A80A
Nchaji AC kacha ugbu a60A80A60A80A
Ọnụ ego kacha dị ugbu a100A80A100A80A
Akụkụ (LxWxH)482x290x113 mm378x280x103 mm426x322x126 mm426x322x126 mm
Nha ịbụ9 n'arọ10 n'arọ8.5 n'arọ11 n'arọ
Oke okpomoku na-arụ ọrụ-10 ruo 50 Celsius
Okpomọkụ nchekwa-15 ruo 60 Celsius
iru mmiri5% to 95% relative humidity (not condensing)

7. Nchọpụta nsogbu

This section provides solutions to common issues you may encounter with your inverter. For problems not listed here, please contact customer support.

  • Inverter anaghị agba ọkụ: Lelee njikọ batrị, hụ na batrị nwere ike irutage is within operating range, verify AC input connection if applicable, and check the input breaker.
  • Enweghị mmepụta AC: Check for overload conditions, ensure the inverter is not in fault mode, verify AC output wiring, and check if the utility grid is present if in utility priority mode.
  • Batrị anaghị akwụ ụgwọ: Verify solar panel connections and voltage, check AC input if AC charging is enabled, ensure charge settings are correct on the display.
  • bufee mkpu: Reduce the connected load. The inverter will automatically restart after a cool-down period if the overload is removed.

8. Nlekọta

Mmezi mgbe niile na-eme ka ogologo ndụ na arụmọrụ kachasị mma nke inverter gị.

  • Nhicha: Periodically clean the inverter's exterior with a dry cloth. Ensure ventilation openings are free from dust and debris.
  • Lelee njikọ: Annually inspect all wiring connections for tightness and signs of corrosion.
  • Nyocha batrị: If using lead-acid batteries, check electrolyte levels and terminal cleanliness regularly.
  • Nyocha gburugburu: Ensure the installation environment remains within specified temperature and humidity ranges.

9. Akwụkwọ ikike na nkwado

WLLKIY products are manufactured to high-quality standards. For warranty information, please refer to the warranty card included with your product or contact your point of purchase. For technical support or service inquiries, please reach out to WLLKIY customer service.

Manufacturer: WLLKIY

© 2024 WLLKIY. All rights reserved.

Akwụkwọ ndị emetụtara - 1005003990425887

Tupuview ECG-LVM7K-SG Hybrid Solar Inverter User Manual - ECGSOLAX
Comprehensive user manual for the ECGSOLAX ECG-LVM7K-SG Hybrid Solar Inverter. Learn about installation, operation, safety, features, and troubleshooting for efficient energy management in residential, commercial, and industrial settings.
Tupuview Schneider Electric ABLU3A48100 Mpempe akwụkwọ ntanetịime ike na-achịkwa
Technical specifications and data for the Schneider Electric ABLU3A48100 regulated power supply, featuring 380-500V AC input, 48V DC output, and 10A current.
Tupuview Príručka k výrobku: Solárny Invertor Sinus Pro Ultra Plus
Podrobná používateľská príručka pre solárny invertor Volt Polska Sinus Pro Ultra Plus, pokrývajúca inštaláciu, prevádzku, nastavenia, špecifikácie a riešenie problémov. Obsahuje informácie o modeloch 7000 24/230V a 12000 48/230V.
Tupuview Invertek OPTIDRIVE™ CP2 AC Variable Speed Drive User Guide
User guide for the Invertek OPTIDRIVE™ CP2 AC Variable Speed Drive (VFD). Covers installation, electrical and mechanical setup, keypad operation, parameter configuration, serial communications, technical data, and troubleshooting for models ranging from 0.75kW to 250kW (1-350HP) with 200-600V input. Essential for industrial motor control applications.
Tupuview NHP ISO Plugs and Sockets: Wiring Instructions for 32A, 40A, 50A Versions
Detailed wiring instructions for NHP ISO industrial strength plugs and sockets, covering 3 and 5 round pin versions (250V and 500V, 32A, 40A, 50A). Includes stripping dimensions and terminal specifications.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.