AODD-15 A/S

AIR Master AODD-15 A/S Air Operated Double Diaphragm Pump User Manual

Model: AODD-15 A/S | Brand: Generic

1. Okwu mmalite

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your AIR Master AODD-15 A/S Air Operated Double Diaphragm Pump. Please read this manual thoroughly before operating the pump to ensure proper function and to prevent injury or damage.

2. Ozi nchekwa

Always observe safety precautions to prevent personal injury and damage to the equipment. This pump operates with compressed air and handles various fluids, some of which may be hazardous.

3. Ngwaahịa gafereview & Atụmatụ

The AIR Master AODD-15 A/S is an Air Operated Double Diaphragm pump designed for versatile fluid transfer applications. It features a durable aluminum body and Santoprene internals, making it suitable for a wide range of industrial uses.

AIR Master AODD-15 A/S Air Operated Double Diaphragm Pump

Foto 1: N'ihu view of the AIR Master AODD-15 A/S Air Operated Double Diaphragm Pump. The pump features a black aluminum body with visible inlet and outlet ports, and a central air motor housing.

Ngwa igodo:

4. Nkọwapụta

OkeUru
NlereanyaAODD-15 A/S
Max. Na-asọ5.0 GPM (18.9 LPM)
Oke. Nrụgide arụ ọrụ100 PSI (0.7 Mpa)
Fluid Inlet Size1/2 inch (DN15) NPT
Fluid Outlet Size1/2 inch (DN15) NPT
Ogo ntinye ikuku1/4 nke anụ ọhịa NPT
Suction Lift (Dry Suction)8 - 10 ft. (2.5 - 3m)
Max. Permitted Grain0.06 inch (1.5mm)
Max. Air Consumption9.0 SCFM
Every Stroke Flow0.006 gal. (23cc)
Every Reciprocating Flow0.012 gal. (46cc)
Max. Reciprocating Speed (Dry Running)320 cpm
Max. Reciprocating Speed (Wet Running)250 cpm
Body Structure MaterialAluminom Alloy
Ihe diaphragmSantoprene
Ibu Ibu25 pound
Akụkụ ngwaahịa15 x 8 x 20 sentimita asatọ
AgbaNwa

5. Ntọala & nwụnye

Ntinye kwesịrị ekwesị dị oke mkpa maka arụmọrụ nke ọkpọkọ ahụ na ogologo oge ya.

  1. Ịkwanye: Securely mount the pump on a stable, level surface capable of supporting the pump's weight and any associated piping and fluid.
  2. Njikọ mmiri mmiri:
    • Connect the fluid inlet line (1/2 inch NPT) to the bottom port of the pump. Ensure the suction line is as short and straight as possible to minimize friction loss.
    • Connect the fluid outlet line (1/2 inch NPT) to the top port.
    • Use appropriate thread sealant on all fluid connections to prevent leaks.
  3. Njikọ ikuku:
    • Connect a clean, dry, regulated air supply to the 1/4 inch NPT air inlet port.
    • An air filter, regulator, and lubricator (FRL unit) are recommended for optimal performance and pump life.
    • Ensure the air supply pressure does not exceed 100 PSI.
  4. Ndozi: For initial startup or after maintenance, ensure the pump is primed by allowing fluid to fill the pump chambers before applying air pressure. This can often be achieved by gravity feeding the fluid to the pump inlet.

6. Ọrụ

Follow these steps for safe and effective pump operation.

  1. Lelee tupu arụ ọrụ:
    • Verify all fluid and air connections are tight.
    • Ensure the fluid supply is adequate.
    • Confirm the air regulator is set to the desired operating pressure (do not exceed 100 PSI).
  2. Ịmalite mgbapụta ahụ:
    • Slowly open the air supply valve to the pump. The pump will begin to cycle.
    • Adjust the air pressure to achieve the desired flow rate. Higher air pressure generally results in higher flow.
  3. Ịkwụsị Mgbapụ:
    • Close the air supply valve to the pump.
    • If necessary, close fluid inlet and outlet valves.
    • Depressurize the system before any disconnection or maintenance.

7. Nlekọta

Nlekọta anya mgbe niile na-eme ka arụmọrụ dị mma ma gbasaa ndụ nke mgbapụta gị.

8. Nchọpụta nsogbu

Nkebi a na-enye azịza maka nsogbu ọrụ a na-ahụkarị.

NsogbuIhe nwere ike imeNgwọta
Pump not cycling or low flowInsufficient air pressure; Clogged air inlet/exhaust; Worn diaphragms; Stuck valve balls; Clogged fluid lines.Increase air pressure; Check air filter/regulator; Clean air lines; Inspect and replace diaphragms; Clean valve balls and seats; Clear fluid lines.
Fluid leaks from pump bodyLoose fasteners; Damaged O-rings/gaskets; Cracked housing.Tighten fasteners; Replace O-rings/gaskets; Inspect housing for damage.
Excessive air consumptionAir motor leak; Worn air valve components.Inspect air motor for leaks; Replace worn air valve components.
Pump cycles but no fluid outputLoss of prime; Suction line air leak; Clogged suction line; Stuck check valve.Re-prime the pump; Check suction line for leaks; Clear suction line obstruction; Inspect and free/replace check valve.

9. Akwụkwọ ikike & Nkwado

For warranty information, technical support, or to order replacement parts, please contact the seller or manufacturer directly. Retain your purchase receipt for warranty claims.

Manufacturer: Air Master

Model Number: AODD-15 A/S

Akwụkwọ ndị emetụtara - AODD-15 A/S

Tupuview Versa-Matic E5 Elima-Matic Bolted Plastic Pump: Service and Operating Manual
This document provides comprehensive service and operating instructions for the Versa-Matic E5 Elima-Matic 1/2" Bolted Plastic pump. It includes detailed information on pump specifications, materials, performance, installation, operation principles, troubleshooting, exploded views, parts lists, warranty, and declarations of conformity.
Tupuview Air Operated Double Diaphragm Pump Instructions
This document provides instructions, product presentation, main applications, performance characteristics, operational principles, and technical specifications for the Air Operated Double Diaphragm Pump series, including models like QBK and QBY. It details installation, maintenance, and troubleshooting information for various industrial and chemical applications.
Tupuview VEVOR Air Operated Double Diaphragm Pump Manual and Specifications
Comprehensive manual for VEVOR Air Operated Double Diaphragm Pumps, covering product presentation, applications, installation, performance characteristics, operational principles, specifications, structural diagrams, parts lists, maintenance, and troubleshooting. Includes model details and technical data.
Tupuview Ntuziaka na nkọwapụta nke mgbapụta diaphragm abụọ nke VEVOR nke ikuku na-arụ ọrụ
Ntuziaka zuru oke, nkọwapụta, na ntuziaka nchọpụta nsogbu maka VEVOR Air Operated Double Diaphragm Pumps, nke gụnyere ụdị QBK na QBY. Gụnyere ngosipụta ngwaahịa, ngwa, njirimara arụmọrụ, ụkpụrụ ọrụ, nkọwa nrụnye, na nchọpụta njehie.
Tupuview Air Operated Double Diaphragm Pump Instructions
Detailed user manual for Air Operated Double Diaphragm Pumps (Models QBK-40L, QBY4-50L, QBY4-25L, QBY4-25LF46, QBY-15PP, QBK-15P, QBK-15). Covers product overview, applications, performance characteristics, installation, operational principles, connection schematics, dimensions, and troubleshooting for industrial and chemical fluid transfer.
Tupuview Air Operated Double Diaphragm Pump Instructions
Comprehensive instructions for Air Operated Double Diaphragm Pumps, covering product presentation, applications, installation, performance characteristics, operational principles, connection diagrams, size charts, and troubleshooting. Includes models QBK and QBY series.