KWS-AC301/KWS-AC300 Digital Power Energy Meter
1. Okwu mmalite
This manual provides detailed instructions for the installation, operation, and maintenance of the IXITAB KWS-AC301/KWS-AC300 Digital AC Power Energy Meter. This device is designed to accurately measure and display AC voltage, current, active power, energy (kWh), and temperature. It is suitable for monitoring electrical parameters in various AC circuits.
2. Ozi nchekwa
Ịdọ aka ná ntị: Electrical shock hazard. Installation and servicing should only be performed by qualified personnel. Failure to follow these instructions may result in serious injury or death.
- Ensure the power supply is disconnected before installation or wiring.
- Agafela voltage and current ratings (AC 50-300V, 100A).
- Ejila ngwaọrụ arụ ọrụ na mmiri ma ọ bụ damp ọnọdụ.
- Debe ngwaọrụ ahụ pụọ na ihe ndị na-ere ọkụ.
- Jide n'aka na njikọ niile dị mma ma ziri ezi tupu i jiri ike.
3. Ngwaahịa gafereview
The KWS-AC301/KWS-AC300 meter features a clear digital display for simultaneous monitoring of multiple electrical parameters. It is compact and designed for easy integration into electrical panels or systems.

Figure 3.1: Product image placeholder. This image indicates that a specific product image is not available. The actual product is a compact digital meter designed for AC electrical measurements.
Atụmatụ gụnyere:
- Real-time measurement of AC Voltage (V), Current (A), Active Power (W), and Energy (kWh).
- Ngosipụta okpomọkụ.
- High accuracy and stability.
- Ngosipụta dijitalụ dị mfe ịgụ.
4. Ntọlite na Wiring
Before proceeding, ensure the main power supply is OFF.
- Ịkwanye: Choose a suitable location for the meter, typically within an electrical panel or enclosure, ensuring adequate ventilation.
- Voltage Input (L/N): Jikọọ AC voltage input wires to the designated L (Live) and N (Neutral) terminals on the meter. Ensure the voltage is within the 50-300V AC range.
- Current Transformer (CT) Connection:
- Pass the load wire (the wire carrying the current you wish to measure) through the hole of the external current transformer (CT).
- Connect the two small wires from the CT to the dedicated CT input terminals on the meter. Pay attention to polarity if indicated, though many simple CTs are non-polar for measurement.
- Njikọ Ibu Ibu: Ensure the load is correctly connected to the circuit being monitored.
- Ike Na: After all connections are verified and secure, restore power to the circuit. The meter should power on and display readings.
Note: The CT must be connected before applying power to the meter to avoid damage. Do not disconnect the CT while power is applied to the meter.
5. Ntuziaka ọrụ
Once powered on, the KWS-AC301/KWS-AC300 meter will automatically begin displaying the measured parameters. The display typically cycles through or shows simultaneously:
- Voltage (V): Displays the current AC voltage.
- Ugbu a (A): Displays the current AC amperage flowing through the monitored circuit.
- Active Power (W): Displays the instantaneous active power consumed by the load.
- Energy (kWh): Accumulates the total energy consumed over time. This value is typically non-volatile and retained even after power loss.
- Okpomọkụ (°C/°F): Displays the ambient temperature measured by the device.
Some models may include a button for resetting the energy (kWh) reading. If present, press and hold the button for approximately 5 seconds to clear the accumulated energy data. Refer to specific product markings for button functionality.
6. Nlekọta
The KWS-AC301/KWS-AC300 meter requires minimal maintenance.
- Nhicha: Use a soft, dry cloth to clean the display and casing. Ejila ihe nhicha ma ọ bụ ihe mgbaze eme ihe.
- Nyocha: Na-enyocha njikọ waya mgbe niile iji hụ na ha dị nchebe.
- Nchekwa: If storing the device for an extended period, keep it in a dry, cool environment, away from direct sunlight and extreme temperatures.
7. Nchọpụta nsogbu
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| No display/Meter not powering on | No power supply; incorrect wiring; faulty unit. | Check power connections. Verify L/N wiring. Ensure power is applied. If problem persists, contact support. |
| Incorrect current reading (0A or very low) | CT not connected; CT connected incorrectly; load wire not passed through CT. | Ensure CT is properly connected to the meter. Verify the load wire passes through the CT. Do not disconnect CT while powered. |
| Vol ezighi ezitage ịgụ | Vol ezighi ezitage input wiring; voltage outside specified range. | Check L/N voltage input connections. Ensure voltage is within 50-300V AC. |
| Energy (kWh) not accumulating | No current flow; faulty unit. | Ensure there is an active load drawing current. Verify current reading is non-zero. |
8. Nkọwapụta
| Oke | Uru |
|---|---|
| Nlereanya | KWS-AC301 / KWS-AC300 |
| Nrụ ọrụ Voltage Oke | AC 50-300V |
| Oke dị ugbu a | 0-100A |
| Oke nha | Voltage, Current, Active Power, Energy (kWh), Temperature |
| Akụkụ ngwugwu | 1.18 x 0.79 x 0.39 sentimita asatọ |
| Ibu Ibu | 1.76 ounces |
| Onye nrụpụta | IXITAB |
| ASIN | B0CSWFLZFL |
| Ụbọchị mbụ dị | Jenụwarị 20, 2024 |
9. Akwụkwọ ikike na nkwado
This product is manufactured by IXITAB. For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly through the platform where the product was purchased. Please have your purchase details and product model number (KWS-AC301/KWS-AC300) ready when contacting support.
For further assistance, you may refer to the product listing on Amazon.com.