Eurom AC3501
Akwụkwọ ntuziaka onye ọrụ Eurom Split Air Conditioner AC3501 Wifi + APP
Model: AC3501 | Brand: Eurom
Okwu mmalite
This manual provides detailed instructions for the safe and efficient operation, installation, and maintenance of your Eurom AC3501 Wifi split air conditioner. This portable unit is designed to provide cooling for various mobile environments such as caravans, motorhomes, campers, boats, and mobile homes, as well as for use in residential spaces like living rooms, bedrooms, and offices. Please read this manual thoroughly before initial use and keep it for future reference.
Ntuziaka nchekwa
Na-agbaso ụkpụrụ nchekwa ndị a mgbe niile ka igbochi mmerụ ahụ ma ọ bụ mebie akụkụ ahụ:
- Ensure the power supply matches the unit's requirements (230 Volt).
- Akwụsịla ntinye ikuku ma ọ bụ ọnụ ụzọ.
- Keep the unit away from water and moisture. The unit has an IP24 protection rating, meaning it is protected against solid objects over 12.5mm and splashing water from any direction.
- Anwala ịrụkwa ma ọ bụ gbanwee unit ahụ n'onwe gị. Kpọtụrụ ndị ọrụ ruru eru.
- Gbaa mbọ hụ na ikuku ventilashị nke ọma na gburugburu nkeji dị n'èzí.
- The unit contains R290 refrigerant. Handle with care and ensure proper disposal.
Ngwa ngwaahịa
The Eurom AC3501 is a split air conditioning system consisting of an indoor unit and an outdoor unit, connected by a flexible hose containing refrigerant lines and electrical cables. The system also includes various accessories for installation.

Figure 1: The indoor and outdoor units of the Eurom AC3501 split air conditioner, shown separated. The indoor unit (left) features a circular fan grille and a control panel, while the outdoor unit (right) has a rectangular grille and a handle for portability.

Figure 2: Key installation accessories for the Eurom AC3501. This includes a flexible white air duct, two white mounting brackets with black adjustment knobs, and a white rectangular adapter for connecting the duct to the unit.
Ntọala na nwụnye
The Eurom AC3501 is designed for flexible installation, particularly suitable for temporary setups in caravans or mobile homes. The two units are permanently connected by a flexible hose.
Nzọụkwụ nwụnye:
- Positioning the Units:
Identify a suitable location for both the indoor and outdoor units. The indoor unit should be placed inside the space to be cooled, while the outdoor unit must be placed outside, ensuring adequate airflow around it. The connecting hose allows for separation of the units.

Figure 3: The indoor unit (top) and outdoor unit (bottom) of the Eurom AC3501 air conditioner shown stacked, with the flexible connecting hose visible at the rear. This configuration is often used for transport or compact storage.

Ọgụgụ 4: Akụkụ view of the Eurom AC3501 units separated, illustrating the flexible hose that connects them. The hose allows for versatile placement of the indoor and outdoor components.
- Window Installation (Caravan/Motorhome):
For caravan or motorhome use, the unit can be mounted in a window opening using the provided brackets. Secure the indoor unit inside and the outdoor unit outside, ensuring the connecting hose passes through the window opening without kinks.

Figure 5: The Eurom AC3501 air conditioner installed in a caravan window. The indoor unit is visible through the window, and the outdoor unit is mounted below it on the exterior of the caravan, connected by the white hose.
- Njikọ ike:
Once positioned, connect the power cable to a suitable 230V power outlet. Ensure the outlet is properly grounded and can handle the unit's power consumption (1025 Watts).
Ntuziaka ọrụ
The Eurom AC3501 can be operated via its integrated control panel or through the Eurom Smart App via Wi-Fi.
Ogwe njikwa gafereview:

Ọgụgụ 6: nso nso view of the Eurom AC3501 control panel. It features a digital display showing temperature (e.g., 18°C) and mode icons, along with touch-sensitive buttons for power, fan speed, mode selection, temperature adjustment (+/-), timer, and Wi-Fi.
- Bọtịnụ ike: Gbanyụọ ma ọ bụ gbanyụọ unit ahụ.
- Nhọrọ ụdị: Cycle through cooling, fan-only, and dehumidifier modes.
- Ndozi okpomọkụ (+/-): Set the desired temperature. The integrated thermostat will maintain this temperature.
- Ọsọ onye ofufe: Adjust the fan speed (low, medium, high).
- Ọrụ ngụ oge: Program the unit to turn on or off at a specific time.
- Wi-Fi/App Control: Connect the unit to your Wi-Fi network and control it remotely using the Eurom Smart App. Refer to the app's instructions for pairing.
For optimal cooling, ensure windows and doors are closed in the area where the unit is operating. The unit has a cooling capacity of 3500 BTU, suitable for spaces up to approximately 24 m³.
Nlekọta
Nlekọta anya mgbe niile na-eme ka ogologo ndụ na arụmọrụ nke ikuku ikuku gị dị ogologo.
- Cleaning the Pre-Filter: The unit is equipped with a pre-filter to capture dust and large particles. This filter should be cleaned regularly (e.g., every two weeks, depending on usage).
- Kwụpụ unit na ike ọkọnọ tupu ihicha.
- Locate and remove the pre-filter (refer to the unit's diagram for exact location).
- Jiri ihe nhicha ikuku hichaa nzacha ahụ ma ọ bụ jiri mmiri ọkụ na ihe nhicha dị nro saa ya nke ọma.
- Kwe ka nzacha ahụ kpoo kpamkpam tupu itinyeghachi ya.
- Nchacha mpụta: Jiri nwayọ hichaa mpụta nke otu ahụ, damp akwa . Ejila kemịkalụ siri ike ma ọ bụ ihe mkpocha abrasive.
- Nchekwa: If storing the unit for an extended period, ensure it is clean and dry. Store it in a cool, dry place, ideally in its original packaging.
Nchọpụta nsogbu
If you encounter issues with your Eurom AC3501, refer to the following common problems and solutions:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Unit anaghị agbanwuo. | No power supply; power cable not connected; power outage. | Check power connection; ensure outlet is functional; check circuit breaker. |
| Ezughi oke jụrụ oyi. | Windows/doors open; dirty air filter; unit too small for the room; blocked air inlets/outlets. | Close windows/doors; clean air filter; ensure unit is appropriately sized for the space; clear obstructions. |
| Mkpọtụ na -adịghị ahụkebe. | Unit not level; foreign object in fan; internal component issue. | Ensure unit is on a flat, stable surface; check for obstructions; if noise persists, contact support. |
| Mgbapu mmiri. | Drainage hose blocked or improperly connected; unit not level. | Check drainage hose for kinks or blockages; ensure proper connection; level the unit. |
If the problem persists after attempting these solutions, please contact Eurom customer support.
Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Nlereanya | AC3501 |
| Ụdị | Euro |
| Ike jụrụ oyi | 3500 BTU |
| Cooling Area (max) | 24 m³ |
| Oriri ike | 1025 Watt |
| Voltage | 230 Volt |
| Igwe nju oyi | R290 (Propane, GWP 3) |
| Klas nchekwa | IP24 |
| Akụkụ (Ngwaahịa) | 37 x 40 x 40 cm |
| Ibu | 23 kilogram |
| Atụmatụ pụrụ iche | Dehumidifier, Wi-Fi, App Control |
| Ụdị nzacha | Tupu nzacha |
Akwụkwọ ikike na nkwado
Eurom products are manufactured to high quality standards. For information regarding warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Eurom website. In case of technical issues or questions not covered in this manual, please contact Eurom customer support.
Ị nwere ike ịchọta ozi ndị ọzọ na nkọwa kọntaktị na Eurom Brand Store on Amazon.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.