1. Okwu mmalite
The Zurn P6900-B-L AquaSense Electronics Module with Solenoid is a replacement component designed for Zurn AquaSense sensor faucets, specifically models Z6912, Z6913, Z6915, and Z6920. This module integrates the solenoid valve, battery pack, and the necessary wiring to connect to the faucet's infrared proximity sensor, enabling hands-free operation. This manual provides instructions for proper installation, operation, and maintenance of the module.
2. Ozi nchekwa
- Gbanyụọ mmiri na paịpụ mmiri tupu ịmalite nrụnye ma ọ bụ ndozi ọ bụla.
- Disconnect electrical power if applicable before servicing.
- Yiri akụrụngwa nchebe kwesịrị ekwesị, dị ka ugogbe nchekwa na uwe aka.
- Gbaa mbọ hụ na njikọ niile echekwabara iji gbochie ntapu.
- Tụfuo batrị ochie nke ọma dịka iwu obodo siri dị.
3. Ihe ngwugwu
Chọpụta na akụrụngwa niile dị tupu ịmalite nrụnye:
- Zurn P6900-B-L AquaSense Electronics Module with Solenoid
- Battery Pack (integrated)
- Batrị Alkaline AA 4 (gụnyere)
- Connecting Wire to Faucet Sensor
- Small Hex Key/Wrench (for securing connections, if applicable)
- O-ring (for sealing connections, if applicable)

4. Ntọala na nwụnye
Follow these steps to install the Zurn P6900-B-L Electronics Module:
- Gbanyụọ ntinye mmiri: Locate the main water shut-off valve for the faucet and turn it off completely.
- Disconnect Old Module (if replacing): Carefully disconnect the existing electronics module from the faucet sensor and water lines. Be prepared for residual water.
- Prepare New Module: Ensure the new P6900-B-L module has the included 4 AA alkaline batteries properly installed in the battery compartment.
- Jikọọ ahịrị mmiri: Attach the solenoid valve portion of the new module to the appropriate hot and cold water supply lines. Use thread sealant tape or pipe dope as recommended by local plumbing codes. Ensure connections are hand-tight, then use a wrench for a final quarter-turn, avoiding overtightening.
- Njikọ waya sensọ: Carefully connect the wire from the electronics module to the faucet's infrared proximity sensor. The connector pins are delicate; align them precisely to avoid bending. Removing any rubber o-ring on the connector might assist in feeling for a solid connection, as a coupler nut typically secures the pieces.
- Modul echedoro: Mount or secure the electronics module in a suitable location, typically under the sink, ensuring it is protected from moisture and easily accessible for future maintenance.
- Weghachite mbubata mmiri: Slowly turn the main water supply back on and check for any leaks at all connection points.
- Ọrụ nnwale: Activate the faucet sensor to verify proper water flow and shut-off.

5. Ntuziaka ọrụ
The Zurn AquaSense Electronics Module controls water flow in conjunction with the faucet's infrared proximity sensor. To operate the faucet:
- Nkwalite: Place your hands within the detection range of the faucet's sensor. The sensor will detect your presence.
- Usoro mmiri: Upon detection, the electronics module will activate the solenoid valve, allowing water to flow from the faucet.
- Nkwụsị: Remove your hands from the sensor's detection range. The module will then close the solenoid valve, stopping the water flow.
The system is designed for hands-free operation, promoting hygiene and water conservation.
6. Nlekọta
Regular maintenance ensures optimal performance and longevity of your Zurn AquaSense Electronics Module.
6.1. Ngbanwe batrị
The module is powered by 4 AA alkaline batteries. When the batteries are low, the faucet may exhibit inconsistent operation or cease to function. To replace the batteries:
- Gbanyụọ ntinye mmiri: Gbanyụọ mmiri na-esi na mmiri.
- Nweta ngalaba batrị: Locate the battery compartment on the electronics module. This is typically secured with a cover.
- Wepu batrị ochie: Open the compartment and remove the old AA batteries.
- Fanye batrị ọhụrụ: Insert four new AA alkaline batteries, ensuring correct polarity (+/-).
- Ụlọ echedoro: Mechie ma sie ike mkpuchi nke ebe batrị ahụ.
- Restore Water Supply and Test: Turn the water supply back on and test the faucet's operation.
6.2. Nhicha
Periodically inspect the module and connections for any signs of corrosion or debris. Clean the exterior of the module with a soft, damp akwa . Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
7. Nchọpụta nsogbu
If your Zurn AquaSense faucet is not functioning correctly, refer to the following table for common issues and solutions:
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| No water flow when sensor is activated | Batrị dị ala ma ọ bụ nwụrụ anwụ Akwụsịla mmiri Sensor wire disconnected or damaged Solenoid valve adịghị arụ ọrụ | Dochie batrị Check water supply valve Verify sensor wire connection Contact Zurn support for solenoid replacement |
| Water flows continuously | Sensọ gbochiri ma ọ bụ mejọrọ Solenoid valve stuck open | Clean sensor lens; check for obstructions Contact Zurn support for solenoid inspection/replacement |
| Mmiri na-adịghị ike | Mmiri dị ala Igwe ikuku mechiri Solenoid partially obstructed | Check building water pressure Clean or replace faucet aerator Contact Zurn support for solenoid inspection |
| Sensọ anaghị aza | Batrị dị ala ma ọ bụ nwụrụ anwụ Sensor lens dirty Sensor wire disconnected or damaged | Dochie batrị Igwe ihe mmetụta dị ọcha Verify sensor wire connection |
8. Nkọwapụta
| Njirimara | Nkọwa |
|---|---|
| Aha Nlereanya | P6900-B-L |
| Nọmba akụkụ | P6900-B-L |
| Ibu Ibu | 1.12 pound |
| Akụkụ ngwaahịa | 6 x 4 x 3.2 sentimita asatọ |
| Ihe onwunwe | Plastic, metal |
| Batrị | 4 AA Alkaline (gụnyere) |
| Compatible Faucets | Z6912, Z6913, Z6915, Z6920 Series |
| Njirimara Pụrụ Iche | Ndu efu |
| UPC | 670240576582 |
9. Akwụkwọ ikike na nkwado
The Zurn P6900-B-L AquaSense Electronics Module is covered by a limited manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your original Zurn product or visit the official Zurn websaịtị.
For technical support, replacement parts, or further assistance, please contact Zurn Customer Service:
- Websaịtị: www.zurn.com
- Ozi mkpọtụrụ: Refer to the 'Contact Us' section on the Zurn websaịtị maka nọmba ekwentị na nkwado email.