AIDA Imaging HD-NDI-CUBE

AIDA HD-NDI-Cube Full HD NDI|HX IP POV Camera User Manual

Comprehensive instructions for the setup, operation, and maintenance of your AIDA HD-NDI-Cube camera.

Ozi nchekwa dị mkpa

  • Gụọ ntuziaka niile nke ọma tupu ị rụọ ọrụ ngwaọrụ.
  • Debe akwụkwọ ntuziaka a maka ntụnye aka n'ọdịnihu.
  • Do not expose the camera to moisture or extreme temperatures.
  • Use only the power adapter specified for this device.
  • Anwala ịkwasa ma ọ bụ gbanwee igwefoto. Kpọtụrụ ndị ọrụ ruru eru ọrụ niile.
  • Ensure proper ventilation around the camera during operation.

Ihe ngwugwu

Chọpụta na ihe niile dị na ngwugwu:

  • AIDA HD-NDI-Cube Camera
  • Power Adapter (typically included for operation)
  • Akwụkwọ (akwụkwọ ntuziaka a)
  • Note: The product listing generically mentions "item" for 'whats_in_the_box'. This manual assumes the camera unit and necessary power supply are included.

Melite

1. Nwụnye anụ ahụ

The AIDA HD-NDI-Cube camera features versatile mounting options for various applications.

  • Identify a suitable location for the camera, ensuring it is stable and has clear line of sight for its intended use.
  • Utilize the top and bottom tripod mounts for secure attachment to tripods, stands, or other mounting hardware.
  • Ensure adequate space for cable connections and ventilation.
AIDA HD-NDI-Cube camera side view

Foto 1: Akụkụ view of the AIDA HD-NDI-Cube camera, showing its compact form factor.

2. Njikọta

Connect the camera to power and network for operation.

  1. Njikọ ike: Connect the provided 12V DC power adapter to the "12VDC" port on the rear of the camera. Plug the adapter into a suitable power outlet. The power indicator LED should illuminate.
  2. Njikọ netwọk: Connect an Ethernet cable from your network switch or router to the "IP/NDI|HX" Ethernet port on the rear of the camera. This connection is essential for NDI|HX video streaming and IP control.
  3. Nwụnye oghere: If a C/CS mount lens is not pre-installed, carefully attach your desired C/CS mount lens to the camera body. Ensure it is securely fastened.
AIDA HD-NDI-Cube camera rear panel with ports

Figure 2: Rear panel of the AIDA HD-NDI-Cube, showing the IP/NDI|HX Ethernet port and 12VDC power input.

AIDA HD-NDI-Cube camera front and side view with lens

Foto 3: N'ihu na akụkụ view of the AIDA HD-NDI-Cube camera, highlighting the C/CS lens mount and SVC port.

Ntuziaka ọrụ

1. Ike izizi

Once connected to power and network, the camera will initiate its startup sequence. The power indicator LED will confirm the device is on.

2. Ịnweta na Web UI

The camera features an accessible web user interface (UI) for configuration and control.

  1. Ensure your computer is on the same network as the camera.
  2. Use a network scanner tool (e.g., NewTek NDI Tools) to discover the camera's IP address on your network.
  3. Mepee a web browser and enter the camera's IP address into the address bar.
  4. Log in using the default credentials (refer to the camera's specific documentation for default username/password, typically "admin" / "admin" or similar).
  5. Site na web UI, you can adjust image parameters, network settings, and stream directly to social media platforms.

3. NDI|HX Video Streaming

The AIDA HD-NDI-Cube outputs Full HD 1080p60 NDI|HX video, compatible with NDI-enabled software and hardware.

  • Once the camera is connected to the network, it should be discoverable by NDI-compatible applications (e.g., OBS Studio, vMix, TriCaster).
  • In your NDI receiving software, select the AIDA HD-NDI-Cube as an NDI source.
  • Adjust video settings within your software or the camera's web UI as needed for optimal performance.

Nlekọta

1. Nhicha

  • Ensure the camera is powered off and disconnected from all sources before cleaning.
  • Use a soft, dry cloth to wipe the camera body. Do not use liquid cleaners or aerosols.
  • Maka oghere, jiri akwa nhicha oghere pụrụ iche na ngwọta iji zere ncha.

2. Mmelite firmware

Periodically check the AIDA Imaging official website for available firmware updates. Firmware updates can improve performance, add features, and resolve issues.

  • Download the latest firmware from the manufacturer's support page.
  • Follow the specific instructions provided with the firmware update package for installation via the camera's web UI.
  • Ịkpachara anya: Do not power off the camera during a firmware update, as this may cause irreversible damage.

Nchọpụta nsogbu

No NDI Signal Detected

  • Njikọ netwọk: Ensure the Ethernet cable is securely connected to both the camera and the network switch/router. Verify network activity lights on the camera's Ethernet port.
  • adreesị IP: Confirm that the camera and the receiving computer are on the same IP subnet. Incorrect subnet masks can prevent NDI discovery. Access the camera's web UI to verify or adjust network settings. A firmware update may be required to resolve specific IP addressing issues.
  • Software Permissions: If using software like OBS Studio on Windows, ensure the application is run with administrator privileges. Some NDI implementations require elevated permissions to access network streams.
  • Ntọala Firewall: Check firewall settings on your computer and network to ensure NDI traffic is not being blocked.

Intermittent Signal Loss

  • Nkwụsi ike netwọk: Verify the stability and bandwidth of your network. NDI|HX requires a stable network connection.
  • Ịdị n'ezi nke eriri USB: Inspect Ethernet cables for damage. Try replacing cables if issues persist.
  • Firmware: Ensure the camera's firmware is up to date. Older firmware versions may have known stability issues.

Ogo onyonyo adịghị mma

  • Ntinye Anya Lens: Adjust the focus of the C/CS mount lens.
  • Ọnọdụ ọkụ: Ensure adequate and appropriate lighting for your scene.
  • Web Ntọala UI: Nweta igwefoto ahụ web UI to adjust image parameters such as exposure, white balance, and color temperature.
  • Mbugharị dijitalụ: Avoid excessive digital zoom, as it can degrade image quality on 1080p cameras. Consider variable focus lens replacements for optical zoom capabilities.

Nkọwa nka nka

NjirimaraNkọwapụta
ỤdịIhe onyonyo AIDA
Nọmba nlereanyaHD-NDI-CUBE
Ụdị ihe mmetụta1/3'' Progressive Scan CMOS
Mkpebi ịse vidiyo1080p (HD zuru ezu)
Mkpebi vidiyo dị irè2.07 MP
Teknụzụ NjikọtaEthernet (NDI|HX)
Ugwu oghereUgwu C/CS
Ogologo Fokalụ kacha nta1 Millimeter (Lens dependent)
Ogologo Focal kacha4 Millimeters (Lens dependent)
Oghere kacha3 f (Lens dependent)
Ụdị elekwasị anyaFixed Focus (Lens dependent)
Ụdị IheKọmpat
AgbaNwa
AtụmatụLow Light Capability
Ndozi onyonyoMba
Ọkwa Nguzogide mmiriỌ bụghị mmiri na-eguzogide
Ụdị ọdịyo akwadoroPCM, MP3, AAC
Usoro Nseta vidiyoASF
Ụdị onyonyo akwadoroJPEG
Oke Akụkụ Foto16:9
Ntọala nha nha ọchaAkpaaka
Ụdị njikwa ngosiMmemme (P)
Ụdị agbapụManual, Automatic, Program (P)
Ngwa dakọtaraPC ma ọ bụ Mac
UPC686091739809

Akwụkwọ ikike na nkwado

Ozi akwụkwọ ikike

AIDA Imaging products are typically covered by a manufacturer's warranty. For specific warranty terms and conditions, including duration and coverage details, please refer to the warranty card included with your product or visit the official AIDA Imaging websaịtị.

Debe ihe akaebe nke ịzụrụ ihe maka akwụkwọ ikike.

Nkwado ndị ahịa

For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact AIDA Imaging customer support.

  • Visit the official AIDA Imaging websaịtị maka akụrụngwa nkwado, FAQs, na ozi kọntaktị.
  • Have your product model number (HD-NDI-CUBE) and serial number ready when contacting support.

Ask a question about this manual