The OMTech Replacement Activated Carbon Filter is an essential component for your XF-180 Fume Extractor, designed to effectively remove unpleasant odors and harmful gases from your workspace. This filter works in conjunction with the primary and HEPA filters to maintain high air quality during fume-heavy applications such as laser engraving, CNC machining, and welding.

Akụkụ ndị bụ isi:

  • XF-180 Specific Replacement: Exact fit for OMTech's industrial-strength XF-180 fume extractors.
  • Ịrụ ọrụ dị elu: Capable of clearing 99.9% of unpleasant odors and harmful fumes, including formaldehyde, benzene, and other chemicals.
  • Ihe nrụpụta adịchaghị: Made from activated charcoal and high-grade melt-blown polypropylene for high absorptive power and durability.
  • Exceptional Longevity: Designed to extend your XF-180's dependable service for up to a year.
  • Nwụnye dị mfe: Simple to fit alongside your smoke extractor's primary and HEPA filters.
OMTech Activated Carbon Filter

Image: The OMTech Replacement Activated Carbon Filter, designed for XF-180 Fume Extractors.

Ntọala na nwụnye

Proper installation ensures optimal performance and air purification. Follow these steps carefully:

Quick and Easy Setup Steps for OMTech Carbon Filter

Image: Visual guide for quick and easy setup of the filter system.

Nzọụkwụ nwụnye:

  1. Nzọụkwụ 1: Remove the cover of your XF-180 Fume Extractor and slot the activated carbon filter into its designated position.
  2. Nzọụkwụ 2: Install the H11 HEPA filter inside the carbon filter, ensuring it is securely seated.
  3. Nzọụkwụ 3: Fit the prefilter into the HEPA filter. Once all filters are in place, replace the machine's cover securely.
OMTech Activated Carbon Filter Dimensions

Image: The activated carbon filter with its approximate dimensions (9.4" x 9.4" x 7.7").

Ntuziaka ọrụ

Once installed, the activated carbon filter works in conjunction with your OMTech XF-180 Fume Extractor to purify the air. Ensure your fume extractor is powered on and operating according to its own manual to begin filtration.

Filter System Overview:

3-Layer Filter System Diagram

Image: Diagram illustrating the 3-layer filter system, including the Nylon Primary Filter, H11 HEPA Filter, and Activated Carbon Filter.

  • Layer 1: Nylon Primary Filter (PM50 Filter) - Captures larger particles. Replacement Cycle: 7–30 Days.
  • Layer 2: H11 HEPA Filter (PM0.5 Filter) - Traps fine particulate matter. Replacement Cycle: 3–6 Months.
  • Layer 3: Ihe nzacha carbon arụgoro arụ ọrụ - Absorbs harmful gases and odors. Replacement Cycle: 6–12 Months.

Nlekọta na ndochi

Regular maintenance and timely replacement of filters are crucial for maintaining optimal air quality and extending the lifespan of your fume extractor. The activated carbon filter is designed for long-term use, but its effectiveness depends on the volume and type of fumes processed.

Usoro ndochi nzacha:

  • Ihe nzacha carbon arụnyere: Replace every 6–12 months, or sooner if persistent odors are detected, indicating saturation.
  • HEPA Myọcha: Replace every 3–6 months.
  • Ihe nzacha izizi: Replace every 7–30 days, or when visibly soiled.

Always use original OMTech replacement filters to ensure compatibility and maintain the performance and warranty of your fume extractor.

N'elu view of OMTech Activated Carbon Filter

Foto: A n'elu-ala view of the activated carbon filter, showing its internal structure.

Nchọpụta nsogbu

If you experience issues with your fume extractor's filtration, consider the following common problems and solutions related to the filter system:

  • Reduced Airflow or Suction: This is typically a sign of a clogged filter. Inspect the primary filter first, as it captures the largest particles. If it's clean, check the HEPA and then the activated carbon filter. Replace any clogged filters.
  • Isi na-adịgide adịgide: If odors persist despite regular primary and HEPA filter changes, the activated carbon filter may be saturated and no longer able to absorb gases. Replace the activated carbon filter.
  • Mkpọtụ na-adịghị ahụkebe: Ensure all filters are correctly seated and the fume extractor unit is stable. Loose filters can cause rattling. If the noise continues, refer to your fume extractor's main manual for further troubleshooting.

For more complex issues or if the problem persists after following these steps, please contact OMTech customer support.

Nkọwapụta

NkọwapụtaNkọwa
Akụkụ ngwugwu11.5 x 10.1 x 10 sentimita asatọ
Nọmba Nlereanya iheXF-180
ASINB09B3KPWBT
Onye nrụpụta kwụsịrịMba
Ibu Ibu2.84 pound
Onye nrụpụtaOMTech
Ụbọchị mbụ dịJulaị 23, 2021
ỤdịOMTech
Ihe onwunwePolypropylene
Ngwa dakọtaraAir Purifier (specifically OMTech XF-180 Fume Extractors)
Ọnụọgụ nke ihe1
Ọkwa ngwaahịaElu
Ọnụọgụ nkeji1.0 Ọnụ

Akwụkwọ ikike na nkwado

OMTech products are designed for durability and performance. For specific warranty details regarding your OMTech XF-180 Fume Extractor and its components, including this activated carbon filter, please refer to the documentation provided with your original fume extractor purchase or visit the official OMTech websaịtị.

For technical support, replacement parts, or any inquiries, please contact OMTech customer service:

  • OMTech Store: Visit OMTech Store on Amazon
  • Ajụjụ izugbe: Refer to the contact information available on the official OMTech websaịtị maka nkwado ozugbo.

Vidiyo: Efereview of OMTech's operations and commitment to quality, showcasing their warehouse and customer support.

OMTech Replacement Activated Carbon Filter for XF180 Fume Extractors - User Manual

Model: XF-180 | © 2025 OMTech. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.