1. Okwu mmalite
This manual provides detailed instructions for the safe and efficient operation, maintenance, and troubleshooting of your Fdit Digital Manifold Refrigeration Gauge. This device is designed for precise measurement of refrigerant pressure and vacuum levels in various refrigeration systems. Please read this manual thoroughly before using the product.
2. Ozi nchekwa
- Always wear appropriate personal protective equipment (PPE) when working with refrigeration systems.
- Ensure the gauge is properly connected to the system before applying pressure.
- Agafela ọkwa nrụgide kachasị nke ngwaọrụ.
- Keep the device away from extreme temperatures, moisture, and corrosive substances.
- Do not attempt to disassemble or modify the gauge, as this may void the warranty and pose safety risks.
- Tụfuo batrị dịka iwu mpaghara siri dị.
3. Ngwaahịa gafereview
The Fdit Digital Manifold Refrigeration Gauge is a portable and durable tool featuring a clear digital display and intuitive controls. It includes a built-in database of 82 refrigerant pressures and corresponding temperatures, and can measure vacuum pressure, indicating the degree of vacuum as a percentage.
3.1 Atụmatụ
- Vol dị oberetage battery indicator for extended battery life (up to 30 hours).
- Integrated database of 82 refrigerant pressures and temperatures.
- Vacuum pressure measurement with percentage gosiri.
- Convenient switching between refrigerant and vacuum measurement modes.
- Compatible with WK-6881H, 6881L, 6882, 6884 systems.
3.2 Akụkụ
Familiarize yourself with the main components of your digital gauge:
- Ngosipụta Digital: Shows pressure, temperature, and vacuum readings.
- Bọtịnụ ngbanwu/ Gbanyụọ: Na-agbanye ngwaọrụ ahụ ma gbanyụọ.
- Bọtịnụ ZERO: Resets the pressure reading to zero.
- Bọtịnụ UNIT: Cycles through available measurement units.
- R+ / R- Buttons: Used for navigating refrigerant types or adjusting settings.
- Port nrụgide: Brass fitting for connecting to refrigeration systems.
- Akụkụ batrị: Located on the back for battery installation.

Foto 1: N'ihu view of the Fdit Digital Manifold Refrigeration Gauge, showing the digital display, ON/OFF, ZERO, UNIT, R+, and R- buttons, and the brass pressure port.

Ọgụgụ 2: Azụ view of the Fdit Digital Manifold Refrigeration Gauge with the battery compartment cover removed, showing the battery terminals.
4. Nhazi
4.1 Ntinye batrị
- Locate the battery compartment on the back of the gauge.
- Gbanyụọ mkpuchi oghere batrị.
- Insert the required batteries (check the battery type and polarity indicated inside the compartment).
- Dochie mkpuchi nke batrị batrị, hụ na ọ pịrị na ebe nchekwa.
Note: The device features a low voltage battery indicator. Replace batteries promptly when this indicator appears to ensure accurate readings.
4.2 Ike mbido
Pịa Gbanye/ Gbanyụọ button to power on the device. The display will illuminate and show initial readings. Allow a few seconds for the gauge to stabilize.
5. Ntuziaka ọrụ
5.1 Gbanyụọ ma ọ bụ gbanyụọ
- Iji gbanye: Pịa Gbanye/ Gbanyụọ bọtịnụ.
- Iji gbanyụọ: Pịa ma jide Gbanye/ Gbanyụọ bọtịnụ maka sekọnd ole na ole ruo mgbe ngosipụta ahụ gbanyụrụ.
5.2 Zeroing the Gauge
Before taking a measurement, it is recommended to zero the gauge to ensure accuracy, especially for vacuum measurements.
- Ensure the gauge is disconnected from any pressure source and is at ambient pressure.
- Pịa ZERO button. The display should show '0' or a very small value.
5.3 Na-agbanwe nkeji nha
Pịa UNIT button repeatedly to cycle through available pressure and temperature units (e.g., kPa, psi, bar, °C, °F).
5.4 Measuring Refrigerant Pressure and Temperature
- Connect the gauge's pressure port to the refrigeration system's service port using appropriate hoses and adapters.
- Ensure the system is stable. The gauge will display the current pressure.
- Jiri ihe R+ na R- buttons to select the specific refrigerant type from the built-in database. The corresponding saturation temperature will be displayed alongside the pressure.
- Record the readings as needed.

Figure 3: The digital gauge connected to a refrigeration manifold, demonstrating its use for measuring pressure and temperature. The display shows current readings and refrigerant type.
5.5 Measuring Vacuum Pressure
The gauge can measure vacuum pressure and display it as a percentage.
- Connect the gauge to the system where vacuum measurement is required.
- Ensure the system is isolated and the vacuum pump is operating.
- The gauge will display the vacuum level, often indicating the degree of vacuum as a percentage of full vacuum.
- Monitor the vacuum level until the desired target is reached.

Figure 4: The digital gauge displaying vacuum pressure, indicating its capability to show the degree of vacuum as a percentage.
6. Nlekọta
6.1 Nhicha
Wipe the gauge with a soft, damp ákwà. Ejila ihe nhicha ma ọ bụ ihe mgbaze, n'ihi na ihe ndị a nwere ike imebi ihe ngosi ahụ ma ọ bụ casing.
6.2 nnọchi batrị
When the low battery indicator appears, replace the batteries as described in Section 4.1. Always use fresh batteries of the specified type.
6.3 Nchekwa
Store the gauge in a clean, dry place away from direct sunlight and extreme temperatures when not in use. Protect the pressure port from dust and debris.
7. Nchọpụta nsogbu
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Gauge anaghị agba ọkụ. | Batrị nwụrụ anwụ ma ọ bụ arụnyere na ezighi ezi. | Lelee polarity batrị; dochie batrị. |
| Ọgụgụ na-ezighi ezi. | A naghị ewepụ ihe nlele ahụ; mmetọ sensọ; njikọ nwere nsogbu. | Perform zero calibration; ensure clean connections; check for leaks. |
| Low battery indicator constantly on. | Batrị dị ala. | Dochie batrị. |
| Cannot select desired refrigerant. | Incorrect operating mode; database limit. | Ensure you are in refrigerant mode; verify if the refrigerant is in the 82-item database. |
8. Nkọwapụta
- Akara: Fdit
- Nọmba nlereanya: Fditxqzwtuec0s191
- Ihe: Plastic
- Ndụ batrị: Ihe dị ka awa 30
- Refrigerant Database: Ụdị 82
- ndakọrịta: WK-6881H, 6881L, 6882, 6884
- Mmalite: China
9. Akwụkwọ ikike na nkwado
For warranty information or technical support, please refer to the product packaging or contact your retailer. Keep your purchase receipt as proof of purchase.
For further assistance, you may visit the official Fdit store or contact their customer service through the details provided at the point of purchase.
Note: The manufacturer is Fdit. For specific inquiries, please contact Fdit directly.