Value VRR24M-C Refrigerant Recovery Unit User Manual

Model: VRR24M-C

Brand: Value

Ngwaahịa gafereview

The Value VRR24M-C is a compact and efficient refrigerant recovery unit designed for professional use. It is suitable for recovering various types of refrigerants, including R12, R134a, R407c, R22, R410a, R32, and R1234yf, among others. Its robust design and user-friendly features make it an essential tool for HVAC/R technicians.

Value VRR24M-C Refrigerant Recovery Unit, front-side view

Image: The Value VRR24M-C Refrigerant Recovery Unit, showcasing its compact design, control panel with gauges, and connection ports. The unit features a sturdy handle for portability and a ventilation grille on the side.

Akụkụ ndị bụ isi:

  • Designed for fast refrigerant recovery.
  • Handy and compact size for easy transport and storage.
  • Equipped with high and low-pressure gauges for precise monitoring.
  • Manual reset function for operational safety.
  • Simple operation knob for ease of use.
  • Air-cooled, oil-free, and maintenance-free piston compressor.
  • Automatic shutdown feature for safety.

Ozi nchekwa

Always read and understand all safety warnings and instructions before operating the VRR24M-C unit. Failure to do so may result in serious injury or equipment damage.

  • Ngwa nchekwa nkeonwe (PPE): Always wear appropriate PPE, including safety glasses, gloves, and protective clothing, when handling refrigerants.
  • Igwe ikuku: Operate the unit in a well-ventilated area to prevent the accumulation of refrigerant vapors, which can displace oxygen and cause asphyxiation.
  • Nchekwa Eletriki: Ensure the power supply matches the unit's requirements (230V/50Hz). Do not operate with damaged cords or plugs. Avoid operating in wet conditions.
  • Ijikwa friji: Be aware of the specific properties of the refrigerant being recovered. Some refrigerants are flammable or toxic.
  • Nchekwa nrụgide: Do not exceed the maximum operating pressures. The unit features an automatic shutdown at 38.5 bar (558 psi).
  • Silinder: Use only approved recovery cylinders. Do not overfill recovery cylinders.
  • Nlekọta: Kwupu ike tupu ime mmezi ma ọ bụ ihicha ọ bụla.

Melite

  1. Iwepu: Carefully remove the VRR24M-C unit from its packaging. Inspect for any shipping damage.
  2. Nkwanye: Place the unit on a stable, level surface in a well-ventilated area, away from direct sunlight or heat sources.
  3. Njikọ ike: Connect the power cord to a grounded 230V/50Hz electrical outlet. Ensure the power switch on the unit is in the "OFF" position before connecting.
  4. Njikọ Hose:
    • Connect the appropriate hoses from the system to be recovered to the "IN" port of the recovery unit.
    • Connect a hose from the "OUT" port of the recovery unit to the recovery cylinder.
    • Gbaa mbọ hụ na njikọ niile siri ike iji gbochie ntapu.
  5. Cylinder Preparation: Ensure the recovery cylinder is empty and has sufficient capacity for the refrigerant being recovered. Weigh the cylinder before and during recovery to prevent overfilling.

Ntuziaka ọrụ

The VRR24M-C unit offers different recovery modes for optimal performance.

Usoro ọrụ izugbe:

  1. Ensure all hoses are correctly connected and valves are in the appropriate positions (refer to your system's specific recovery procedure).
  2. Tụgharịa isi ọkụ ọkụ na ọnọdụ "ON".
  3. Select the desired recovery mode using the operation knob (e.g., Gas, Liquid, Push/Pull).
  4. Monitor the high and low-pressure gauges during the recovery process.
  5. The unit will automatically shut off if the pressure exceeds 38.5 bar (558 psi).
  6. Once recovery is complete, or the system pressure reaches the desired vacuum level, turn off the unit and close all valves.
  7. Disconnect hoses carefully, being mindful of any residual pressure.

Recovery Efficiency (Approximate):

Refrigerant CategoryỤdịEfficiency (kg/min)
Category III (e.g., R12, R134a, R401c, R406a, R500, R1234yf)Gas2.6
Liquid / Push / Pull7.50
Category IV (e.g., R22, R401a, R401b, R402b, R407c, R407d, R408a, R409a, R502, R509)Gas2.9
Liquid / Push / Pull8.50
Category V (e.g., R402a, R404a, R407a, R407b, R410a, R507, R32)Gas3.9
Liquid / Push / Pull9.50

Note: Recovery efficiency may vary based on ambient temperature, system conditions, and refrigerant type.

Nlekọta

Regular maintenance ensures the longevity and optimal performance of your VRR24M-C unit.

  • Nhicha: Keep the unit clean and free of dust and debris. Wipe the exterior with a damp akwa . Ejila kemịkalụ siri ike.
  • Nyocha hose: Regularly inspect hoses and fittings for wear, cracks, or leaks. Replace damaged components immediately.
  • Nlekọta ihe nzacha: If applicable, check and clean or replace any internal filters according to the manufacturer's recommendations (no specific filter mentioned in data, so keep general).
  • Nchekwa: When not in use, store the unit in a dry, cool place, protected from extreme temperatures and direct sunlight.
  • Compressor: The unit features an oil-free and maintenance-free piston compressor, reducing routine maintenance needs for this component.

Nchọpụta nsogbu

This section provides solutions to common operational issues. For problems not listed here, contact qualified service personnel.

NsogbuIhe kpatara/ Ngwọta nwere ike ime
Unit anaghị agbanye ọkụ.
  • Lelee ma ọ bụrụ na e tinyere eriri ọkụ eletrik n'ime oghere dị ndụ.
  • Nyochaa ngbanwe ọkụ dị na ọnọdụ "ON".
  • Lelee ihe mgbawa sekit ma ọ bụ fuse maka ebe ọkụ eletrik.
Slow recovery rate.
  • Ensure hoses are properly connected and not kinked.
  • Check for blockages in hoses or filters.
  • Verify the correct recovery mode (Gas/Liquid) is selected for the refrigerant state.
  • Ambient temperature may be too low (operating temperature 0-40°C).
Unit shuts down automatically.
  • High-pressure shutdown: The pressure may have exceeded 38.5 bar (558 psi). Check for overfilled recovery cylinder or blockages.
  • Overheating: Ensure adequate ventilation around the unit. Allow the unit to cool down.
Refrigerant leaks detected.
  • Tighten all hose connections and fittings.
  • Inspect hoses for damage and replace if necessary.
  • Check O-rings and seals on connections.

Nkọwapụta

OkeUru
Ụdị ngwaahịaVRR24M-C
Igwe nju oyi dakọtaraCategory III: R12, R134a, R401c, R406a, R500, R1234yf
Category IV: R22, R401a, R401b, R402b, R407c, R407d, R408a, R409a, R502, R509
Category V: R402a, R404a, R407a, R407b, R410a, R507, R32
Ịnye ọkụ230V / 50Hz
Ike moto1 HP
Ọsọ moto3000 RPM
Kachasị ugbu a5 A
Ụdị CompressorPiston compressor, air-cooled, oil-free, maintenance-free
Automatic Shutdown Pressure38.5 bar / 3850 kPa (558 psi)
Okpomọkụ na-arụ ọrụ0-40 Celsius C
Akụkụ (L x W x H)370 x 250 x 300 mm
Ibu11.5 n'arọ
Ngwa dakọtaraRefrigerator, Air Conditioner, Cooling Unit

Akwụkwọ ikike na nkwado

Specific warranty details are not provided in the product information. Please refer to your purchase documentation or contact the retailer/manufacturer for warranty terms and conditions.

For technical support or service inquiries, please contact Value customer service or your authorized dealer.

© 2024 Value. All rights reserved.