Zerone External S Meter SWR Power Meter User Manual

Model: Zer onekda4y0nmoz

Akara: Zeron

Okwu mmalite

This user manual provides comprehensive instructions for the Zerone External S Meter SWR Power Meter, designed specifically for use with Yae FT-857D and FT-897 transceivers. This high-performance meter offers excellent durability and stability, clearly displaying critical parameters such as automatic level control voltage, modulation level, standing wave ratio, and supply voltage.

  • Only applicable for Yae FT-857D and FT-897.
  • Clearly displays the automatic level control voltage, modulation level, standing ratio, and supply voltage.
  • High performance and super stability.
  • Ọ dị mfe ịrụ ọrụ.
  • High quality and excellent durability.

Ntọlite ​​na calibration

Receive Display Settings

To configure the meter for receive display:

  1. Pịa (FUNC) key to enter the setup menu and enable the extended menu.
  2. Tugharia (Họrọ) to call up setup menu item No-061 (MTR ARX SEL).
  3. Tugharia (DIAL) to select an external instrument display option from the following:
    • -SIG
    • -CTR
    • -VLT
    • -N / A
    • -FS: Buckle in the instrument 1mA full scale output calibration standard external instruments.
    • - Gbanyụọ
  4. Pịa (FUNC) to save the settings and exit the setup menu.

Emission Display Settings

To configure the meter for emission display:

  1. Pịa (FUNC) key to enter the setup menu and enable the extended menu.
  2. Tugharia (Họrọ) to call up setup menu item No-061 (MTR ARX SEL).
  3. Tugharia (DIAL) to select an external instrument display option from the following:
    • -PWR
    • -ALC
    • - MOD
    • -SWR
    • -VLT
    • -N / A
    • - Gbanyụọ

Usoro mmezi

To calibrate the meter for accurate readings:

  1. Pịa (FUNC) key to enter the setup menu and enable the extended menu.
  2. Tugharia (Họrọ) to call up setup menu item No-060 (MTR ARX SEL).
  3. Tugharia (DIAL) ịhọrọ FS.
  4. Using a small flathead screwdriver, adjust the calibration adjustment hole at the rear of the unit until the meter pointer reaches full scale.
  5. Nhazi ahụ ezuola.
Zerone External S Meter with cable

Figure 1: The Zerone External S Meter with its connecting cable.

Close-up of Zerone S Meter display face

Ọgụgụ 2: A zuru ezu view of the meter's display face, showing SIG, PWR, SWR, MOD, VOLT, and DISC scales.

Na-arụ ọrụ mita

Once properly set up and calibrated, the Zerone External S Meter provides real-time readings for various radio parameters. The meter's needle will indicate values on the selected scale (SIG, PWR, SWR, MOD, VOLT, DISC) based on your radio's operation mode (receive or transmit).

Refer to your Yaesu FT-857D or FT-897 transceiver's manual for specific interpretations of these readings in different operating scenarios.

Zerone S Meter displaying various parameters

Figure 3: The meter clearly displays automatic level control voltage, modulation level, standing wave ratio, and supply voltage.

Nlekọta

The Zerone External S Meter is designed for durability. Regular maintenance is minimal but important for continued accuracy and longevity.

  • Keep the meter clean and free from dust. Use a soft, dry cloth to wipe the casing and display face.
  • Avoid exposing the meter to extreme temperatures or direct sunlight for prolonged periods.
  • If the meter's pointer does not return to zero when the unit is off or disconnected, it may be due to transit bumps. In such cases, carefully adjust the self-zeroing screw located on the mask-side of the instrument. This screw is typically black.
Zerone S Meter with dimensions

Figure 4: Dimensions of the Zerone External S Meter: 6.7 cm * 7 cm * 6 cm.

Nchọpụta nsogbu

This section addresses common issues you might encounter with your Zerone External S Meter.

Hidden Menu Access

If you are unable to find menu items No-060 or No-061 in your radio's setup menu, these menus might be hidden. To access them:

  1. Pịa ogologo F key on your radio to open the menu settings.
  2. Set the relevant menu option to ON to reveal the hidden menus.
  3. Pịa F key again to exit and save the settings.

Static Pointer / Zeroing Issues

The instrument is calibrated at delivery. However, transit bumps can sometimes cause the pointer to not rest at zero. If this occurs:

  • Locate the black self-zeroing screw on the mask-side of the instrument.
  • Gently adjust this screw with a small flathead screwdriver until the pointer rests at the zero mark.

Nkọwapụta

NjirimaraNkọwa
ỤdịZerone
Nọmba nlereanyaZer onekda4y0nmoz
Redio dakọtaraYaesu FT-857D, FT-897
Ibu Ibu10.2 ounces (0.29 Kilogram)
Nha ihuenyo3.5 sentimita asatọ
Mba onye siChina
UPC745781109282
Mbụ DịỌgọst 12, 2019

Ozi akwụkwọ ikike

Specific warranty details for the Zerone External S Meter are not provided in this manual. Please refer to the product packaging or contact Zerone customer support for information regarding warranty coverage and terms.

Nkwado ndị ahịa

For technical assistance, troubleshooting, or general inquiries about your Zerone External S Meter, please visit the official Zerone store or contact their customer service department. Contact information can typically be found on the product packaging or the manufacturer's official websaịtị.

Ị nwekwara ike ịga na Zerone Store on Amazon maka ozi ngwaahịa na akụrụngwa nkwado.

© 2024 Zerone. All rights reserved.