Pedrollo Easy Press-1

Pedrollo Easy Press-1 Electronic Pressure Controller User Manual

Model: Art.50066/115

1. Okwu mmalite

The Pedrollo Easy Press-1 is an electronic pressure controller designed for single-phase electric pumps. This device automates the starting and stopping of the pump based on water demand (opening and closing of taps). It incorporates microprocessor logic to protect the pump from dry running, offering both automatic and manual reset functions. Furthermore, it safeguards the electric pump against frequent starts caused by minor leaks in the system. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Easy Press-1 controller.

2. Ozi nchekwa

Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.

  • Nchekwa Eletriki: Always disconnect power before performing any electrical connections or maintenance. Ensure all wiring complies with local electrical codes.
  • Nwụnye ọkachamara: Ekwesịrị ịrụ ọrụ naanị ndị ọrụ ruru eru.
  • Nrụgide mmiri: Ekwela ka nrụgide ọrụ kachasị elu akọwapụtara maka ngwaọrụ ahụ gafere.
  • Oke okpomọkụ: Operate the device only within the specified minimum and maximum operating temperatures.
  • Nchedo: The device has an IP65 protection rating, meaning it is protected against dust and low-pressure water jets. However, it should not be submerged.

3. Ngwaahịa gafereview

The Pedrollo Easy Press-1 is an orange-colored electronic unit with integrated pressure sensors and control logic. It features clear indicators for its operational status.

Pedrollo Easy Press Electronic Pressure Controller, orange unit with blue label showing 'EASY PRESS II Electronic', 'POWER', 'STATUS', 'START/STOP' buttons, and 'MADE IN ITALY Max 10 bar IP 65 CE PEDROLLO' markings.

Foto 1: Pedrollo Electronic Pressure Controller. This image displays the general appearance of a Pedrollo electronic pressure controller, an orange unit with a blue label. The label indicates "EASY PRESS II Electronic", along with indicators for "POWER" and "STATUS", and a "START/STOP" button. Technical markings include "MADE IN ITALY Max 10 bar IP 65 CE PEDROLLO". Please note that while this image shows "EASY PRESS II", the manual refers to the "Easy Press-1" model.

3.1. Ihe mejupụtara na ihe ngosi

  • Ihe ngosi ike: (Green LED) Illuminates when the device is powered.
  • Ngosipụta ọnọdụ: (Red LED) Indicates operational status or fault conditions, such as dry running.
  • Bọtịnụ mmalite/Kwụsị: Used for manual pump control and resetting after a dry-run protection event.
  • Njikọ mbata/Ọpụpụ: Threaded connections for integration into the water system.

4. Nka na ụzụ nkọwa

OkeUru
NlereanyaEasy Press-1 (Art.50066/115)
Ịnye ọkụ Voltage230 Volt (single-phase)
Ugboro ugboro50/60 Hz
Kachasị ugbu a10/16 A
Ogo nchekwaIP65
Nrụgide arụ ọrụ kacha10 mmanya
Okpomọkụ arụ ọrụ kacha nta0 Celsius C
Okpomọkụ arụ ọrụ kacha65 Celsius C
Njikọ1-inch male threads
Minimum Intervention Pressure1.5 mmanya
Akụkụ (L x H x D)174 x 221 x 174 mm
Ibu4.5 n'arọ
Ihe onwunweNkedo Ígwè

5. Nwụnye

Proper installation is crucial for the safe and efficient operation of the Easy Press-1. It is highly recommended that installation be carried out by a qualified technician.

5.1. Ebe Nkwanye

  • Install the device in a vertical position, ensuring the flow direction arrows on the unit match the water flow.
  • Choose a location protected from direct sunlight, frost, and excessive humidity.
  • Gbaa mbọ hụ na ikuku ikuku zuru oke gburugburu unit ahụ.

5.2. Hydraulic Connections

  1. Connect the inlet of the Easy Press-1 to the pump outlet.
  2. Connect the outlet of the Easy Press-1 to the water distribution system.
  3. Use appropriate sealing materials (e.g., PTFE tape) on the 1-inch male threaded connections to prevent leaks.
  4. Hụ na njikọ niile siri ike mana ejidela ya nke ukwuu.

5.3. Njikọ eletrik

  1. Ịdọ aka ná ntị: Hụ na e mechichara isi ihe na-enye ọkụ eletrik tupu ị rụọ njikọ ọ bụla.
  2. Connect the main power supply (230V, 50/60Hz) to the designated input terminals of the Easy Press-1.
  3. Connect the single-phase electric pump to the designated output terminals of the Easy Press-1.
  4. Ensure proper grounding for both the Easy Press-1 and the electric pump.
  5. Verify all connections are secure and insulated according to electrical standards.

6. Ọrụ

6.1. Mmalite mmalite

  1. After completing all hydraulic and electrical connections, ensure the pump is primed (filled with water) if required by the pump manufacturer.
  2. Open a tap in the system to allow water to flow.
  3. Restore power to the Easy Press-1. The green POWER indicator should illuminate.
  4. The pump will start automatically and run until the system is pressurized and the tap is closed.
  5. Close the tap. The pump should stop after a few seconds.

6.2. Ịrụ ọrụ nkịtị

The Easy Press-1 operates automatically:

  • When a tap is opened, the pressure in the system drops, and the Easy Press-1 starts the pump.
  • When the tap is closed, the pressure rises, and the Easy Press-1 stops the pump after a short delay.

6.3. Dry-Run Protection and Automatic Reset

If the pump runs without water (dry running), the Easy Press-1 will detect this condition and stop the pump to prevent damage. The red STATUS indicator will illuminate.

  • Ntọgharị akpaaka: The device will attempt to restart the pump periodically (e.g., every 15-30 minutes) to check if water has returned. If water is detected, normal operation resumes.
  • Tọgharia akwụkwọ ntuziaka: To manually reset the device after a dry-run event, press the START/STOP button. Ensure the water supply to the pump has been restored before attempting a manual reset.

7. Nlekọta

The Pedrollo Easy Press-1 is designed for minimal maintenance. However, regular checks can ensure its longevity and optimal performance.

  • Nlele anya: Periodically inspect the unit for any signs of damage, leaks, or corrosion.
  • Ịdị ọcha: Keep the exterior of the unit clean and free from dust and debris. Use a soft, damp cloth for cleaning; do not use abrasive cleaners or solvents.
  • Njikọ: Check hydraulic and electrical connections periodically to ensure they remain tight and secure.
  • Oge oyi: In areas prone to freezing temperatures, ensure the unit and associated piping are drained or protected from frost to prevent damage.

8. Nchọpụta nsogbu

This section provides solutions to common issues you might encounter with your Easy Press-1 controller.

NsogbuIhe nwere ike imeNgwọta
Pump does not start when tap is opened.Enweghị ọkụ.
Dry-run protection activated.
Wiwi na-ezighi ezi.
Lelee njikọ ọkụ na ihe nkwụsị sekit.
Check water supply to pump; press START/STOP button to reset.
Verify all electrical connections are secure. Consult a qualified technician.
Mgbapụta ọkụ na-aga n'ihu.Mbelata na sistem.
Tap not fully closed.
Pressure sensor malfunction.
Inspect plumbing for leaks and repair.
Ensure all taps are completely closed.
Kpọtụrụ nkwado teknụzụ.
Pump starts and stops frequently (short cycling).Small leak in the system.
Check valve issue.
Enweghi oke mmiri.
Inspect plumbing for minor leaks and repair.
Check the pump's check valve for proper function.
Ensure adequate water supply to the pump.
Red STATUS indicator is on.Dry-run protection activated.Check water supply to the pump. Once water is restored, press the START/STOP button to manually reset, or wait for automatic reset.

9. Akwụkwọ ikike na nkwado

For warranty information, please refer to the documentation provided at the time of purchase or contact your authorized Pedrollo dealer. Keep your proof of purchase for warranty claims.

For technical assistance, spare parts, or service, please contact Pedrollo customer support or an authorized service center. Contact details can typically be found on the manufacturer's official websaịtị ma ọ bụ site na onye na-ere ahịa gị.

Ask a question about this manual