REHAU 13360241001

Rehau Nea H 24 13360241001 Wired Room Thermostat 24V User Manual

Ụdị: 13360241001 | Ụdị: REHAU

1. Okwu mmalite

This manual provides detailed instructions for the installation, operation, and maintenance of the Rehau Nea H 24 Wired Room Thermostat 24V. This device is designed for controlling the ambient temperature of surface heating systems.

The Rehau Nea H 24 thermostat is CE and VDE approved according to EN 60730-2-9 and EN 60730-1 standards, ensuring reliable and safe operation.

2. Ntuziaka nchekwa

  • Nchekwa Eletriki: Installation and wiring must be performed by a qualified electrician in accordance with local electrical codes and regulations. Ensure the power supply is disconnected before any installation or maintenance work.
  • Voltage: This thermostat operates on 24V. Do not connect it to higher voltage sistemu.
  • gburugburu: Do not expose the device to moisture, extreme temperatures, or direct sunlight.
  • Ijikwa: Handle the thermostat with care to avoid physical damage.
  • mkpofu: Dispose of the product and its components responsibly, following local environmental regulations.

3. Ihe ngwugwu

Please check the package contents upon unpacking to ensure all parts are present:

  • Rehau Nea H 24 Wired Room Thermostat
  • Mgbidi arịọnụ mgbodo
  • Up to 5 actuators (depending on specific kit/purchase)
  • Akwụkwọ ntuziaka (akwụkwọ a)

4. Ntọala na nwụnye

4.1 Na-arịgo

The Rehau Nea H 24 thermostat is suitable for mounting on a flush-mounted box or directly on the wall. Choose a location that accurately represents the room's temperature, away from direct heat sources, drafts, or direct sunlight.

4.2 Waya

This thermostat uses a wired connection and operates on 24V. It can connect to a maximum of 5 servo motors. Refer to the wiring diagram provided with your heating system or consult a qualified electrician for proper connection. Ensure all connections are secure and insulated.

N'ihu view of the Rehau Nea H 24 Wired Room Thermostat. It is white with a grey rectangular display in the center. Below the display, the 'REHAU' logo is visible. To the left of the display is a '-' button, and to the right is a '+' button.

Foto 1: N'ihu view of the Rehau Nea H 24 Wired Room Thermostat. The thermostat is white with a central grey rectangular display. A minus button (-) is located to the left of the display, and a plus button (+) is to the right. The REHAU logo is printed at the bottom center of the unit.

5. Ntuziaka ọrụ

The Rehau Nea H 24 thermostat offers various operating modes and features to manage your surface heating system efficiently.

5.1 Ụdị arụ ọrụ

  • Ụdị akpaaka: The thermostat follows a pre-programmed schedule (if connected to an external digital timer like the Nea timer).
  • Ụdị nkịtị: Maintains a comfortable set temperature.
  • Ụdị ewelatalata: Maintains a lower, energy-saving temperature.
  • Optional Modes: Additional modes may be available depending on the connected external timer or system configuration.

5.2 Atụmatụ

  • Mbelata okpomọkụ: Can be achieved via an external digital timer (e.g., Nea timer) for scheduled energy savings.
  • Ọrụ Nchekwa oyi: Automatically activates heating to prevent pipes from freezing if the temperature drops below a set threshold.
  • Valve Protection Function: Periodically cycles the heating valves to prevent them from seizing due to inactivity.
  • Ngosipụta ụbọchị: The thermostat features a display that can show the current date.
  • Ndozi okpomọkụ: Use the '+' and '-' buttons to adjust the desired temperature setpoint.

6. Nlekọta

The Rehau Nea H 24 thermostat requires minimal maintenance.

  • Nhicha: Wipe the surface of the thermostat with a soft, dry, or slightly damp cloth. Do not use abrasive cleaners, solvents, or chemical sprays, as these can damage the casing ma ọ bụ ihe ndị dị n'ime.
  • Nyocha: Periodically check the wiring connections for any signs of wear or looseness. Ensure the thermostat is securely mounted.

7. Nchọpụta nsogbu

If you encounter issues with your Rehau Nea H 24 thermostat, refer to the following common problems and solutions:

NsogbuIhe nwere ike imeNgwọta
Thermostat not powering on / No display
  • Enweghị ike ọkọnọ (24V)
  • Wiwi na-ezighi ezi
  • Igwe ọkụ sekit gbawara agbawa ma ọ bụ gbajiri agbaji
  • Mmejọ nke ime
  • Check the 24V power supply to the thermostat.
  • Verify wiring connections according to the installation diagram. Ensure polarity is correct.
  • Check your electrical panel for tripped breakers or blown fuses.
  • If the issue persists after checking power and wiring, contact a qualified technician or Rehau support.
Heating not responding to thermostat settings
  • Incorrect operating mode selected
  • Issue with connected actuators/servo motors
  • External timer interference
  • Thermostat adịghị arụ ọrụ
  • Ensure the thermostat is in the desired operating mode (e.g., Normal, Automatic).
  • Check the connection and functionality of the servo motors.
  • If an external timer is used, verify its settings and operation.
  • Consult a professional if the thermostat appears to be faulty.
Ọgụgụ okpomọkụ ezighi ezi
  • Thermostat location affected by drafts or heat sources
  • Ihe mmetụta sensọ adịghị arụ ọrụ
  • Ensure the thermostat is not exposed to direct sunlight, drafts from windows/doors, or heat from appliances.
  • If the problem persists, the sensor may be faulty, requiring professional inspection.

Note: One user reported a circuit board issue upon initial power-on. This is often related to incorrect wiring or power supply issues rather than a defect in the thermostat itself. Always ensure correct voltage and wiring before powering on.

8. Nka na ụzụ nkọwa

Nọmba nlereanya13360241001
ỤdịREHAU
NgwaAmbient temperature control for surface heating systems
Voltage24 volts
Teknụzụ NjikọtaEkwenyere
Ụdị njikwaPịa bọtịnụ
Ụdị njikwa okpomọkụProgrammable (with external timer)
Akụkụ (L x H x D)88 x 88 x 26 mm
Klas nchekwaIP30
AgbaFront: Signal White (RAL 9016), Back: Anthracite Grey (RAL 7016)
Ibu130 grams
Max. Servomotors5 (connectable)
Atụmatụ pụrụ icheDate display, Frost protection, Valve protection
AsambodoCE according to EN 60730-2-9 and EN 60730-1, VDE according to EN 60730-2-9 and EN 60730-1

9. Akwụkwọ ikike na nkwado

Information regarding specific spare parts availability is not provided. For warranty claims, technical support, or service inquiries, please contact REHAU customer service directly or refer to their official websaịtị maka nkọwa kọntaktị.

It is recommended to keep your purchase receipt as proof of purchase for any warranty-related matters.

© 2024 REHAU. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.