BMC E-20A-H

BMC RESmart GII Auto CPAP E-20A-H with Humidifier User Manual

Model: E-20A-H

1. Okwu mmalite

This manual provides essential information for the safe and effective operation, setup, and maintenance of your BMC RESmart GII Auto CPAP System E-20A-H with Humidifier. Please read this manual thoroughly before using the device and retain it for future reference. This device is intended for the treatment of Obstructive Sleep Apnea (OSA).

2. Ozi nchekwa

Ịdọ aka ná ntị nchekwa dị mkpa:

  • Always disconnect the device from the power supply before cleaning or performing any maintenance.
  • Ejila ngwaọrụ ahụ n'ime mmiri ma ọ bụ mmiri mmiri ọ bụla ọzọ.
  • Use only accessories and parts recommended by BMC.
  • Keep the device away from direct sunlight, heat sources, and sharp objects.
  • Consult your physician or healthcare provider if you experience any unusual symptoms or discomfort during use.
  • Ezubere ngwaọrụ a maka nkwado ndụ.

3. Ngwaahịa gafereview

The BMC RESmart GII Auto CPAP System E-20A-H is an intelligent device designed for the treatment of Obstructive Sleep Apnea. It features an integrated humidifier for enhanced comfort.

Isi ihe:

  • Isi ngalaba: Houses the motor, control electronics, and display.
  • Igwe iru mmiri: Integrated unit with dual water chambers for efficient humidification.
  • Ngosipụta LCD 3.5 inch: Provides real-time information and access to settings.
  • Control akpu: For navigating menus and adjusting settings.
  • Ọpụpụ ikuku: Connects to the CPAP tubing.
  • Ntinye ike: Maka ijikọ nkwụnye ọkụ.
  • Oghere kaadị SD: For compliance data storage and retrieval (iCode II).
  • SpO2 Kit Port (Optional): For real-time blood oxygen saturation and pulse rate monitoring.
BMC RESmart GII Auto CPAP System with Humidifier

An image showing the BMC RESmart GII Auto CPAP device, featuring its main unit, control knob, and integrated humidifier. The device is black with a clear humidifier chamber visible.

4. Nhazi

4.1 Nwepu

  1. Jiri nlezianya wepụ ihe niile dị na nkwakọ ngwaahịa.
  2. Lelee ngwaọrụ ahụ na ihe ndị ọzọ dị na ya maka ihe ịrịba ama ọ bụla nke mmebi. Ejila ya ma ọ bụrụ na ọ mebiri emebi.

4.2 Ijikọ ike

  1. Connect the power adapter to the power inlet on the back of the device.
  2. Tinye eriri ọkụ n'ime ebe eletrik kwesịrị ekwesị.

4.3 Filling the Humidifier

  1. Open the humidifier chamber by sliding or lifting the cover.
  2. Fill the water chamber with distilled water up to the maximum fill line. Do not overfill.
  3. Close the humidifier chamber securely.

4.4 Connecting Tubing and Mask

  1. Connect one end of the CPAP tubing to the air outlet on the device.
  2. Connect the other end of the tubing to your prescribed CPAP mask.
  3. Fit the mask comfortably and securely according to its own instructions.

5. Ntuziaka ọrụ

5.1 Starting Therapy

  1. Ensure the device is properly set up and connected.
  2. Tinye ihe nkpuchi gị.
  3. Press the Start/Stop button (usually the control knob) to begin therapy. The device will automatically start delivering air.

5.2 nhazi nhazi

Use the control knob to navigate the menu on the 3.5-inch LCD display. Press the knob to select an option and rotate to adjust values.

  • Oke nrụgide: 4-20 cm H2O (Auto CPAP adjusts automatically within this range).
  • Ramp Oge: Adjusts the time (0-60 minutes) for the pressure to gradually increase to the prescribed level.
  • Humidification Level: Select from Off or levels 1-5 to control the humidity output.
  • Reslex: Pressure relief feature (Off/1/2/3) for exhalation comfort.
  • Gbanyụọ/ gbanyụọ akpaaka: Can be enabled or disabled (Off by default).

5.3 Stopping Therapy

Press the Start/Stop button again to end therapy. The device will power down.

5.4 iCode II Data Retrieval

Compliance data is encoded by a QR code displayed on the device's screen. Use a compatible application to scan the QR code for quick data retrieval and monitoring.

6. Nlekọta

Regular cleaning and maintenance are crucial for the optimal performance and longevity of your device.

6.1 Nhicha kwa ụbọchị

  • Humidifier Water Chamber: Empty any remaining water and rinse with distilled water. Allow to air dry.
  • Ihe mkpuchi: Wipe down the mask cushion with a damp cloth or specialized CPAP wipes.

6.2 Nhicha kwa izu

  • Humidifier Water Chamber: Wash with mild soap and warm water. Rinse thoroughly and allow to air dry completely.
  • CPAP tubing: Wash with mild soap and warm water. Rinse thoroughly and hang to air dry.
  • Ihe nzacha ikuku: Inspect the reusable air filter (if applicable). If dirty, rinse under running water and allow to air dry. Replace disposable filters as recommended.

6.3 Nlekọta n'ozuzu

  • Jiri mgbasa ozi hichapụ mpụta ngwaọrụ ahụamp cloth. Do not use abrasive cleaners or immerse the device.
  • Replace air filters regularly as per manufacturer recommendations or if visibly dirty.

7. Nchọpụta nsogbu

Ọ bụrụ na ị na-enwe nsogbu, rụtụ aka na nsogbu ndị a na-ahụkarị na ngwọta ndị a:

NsogbuIhe nwere ike imeNgwọta
Enweghị ikeAkwụsịla eriri ike; Ike gitageCheck power connections; Restore power supply
Air leak from maskMask not fitted correctly; Mask worn outAdjust mask straps; Replace mask cushion or mask
Dry mouth/throatHumidifier off or set too low; Water chamber emptyIncrease humidification level; Refill water chamber
Ngwaọrụ na-eme mkpọtụAir filter dirty or blocked; Device on an uneven surfaceClean or replace air filter; Place device on a stable, flat surface
Pressure feels too high/lowIncorrect pressure setting; Ramp feature activeConsult your physician for pressure adjustments; Wait for ramp imecha

If the problem persists, contact your healthcare provider or the manufacturer's customer support.

8. Nkọwapụta

NjirimaraNkọwapụta
NlereanyaE-20A-H
ỤdịCPAP / Auto
Oke nrụgide4-20 cm H2O
Pressure Increment0.5 cm H2O
Ramp OgeNkeji 0-60
ReslexGbanyụọ/1/2/3
Ọkwa ụda<30 dBA
Humidification LevelsGbanyụọ / 1-5
Ngosipụta3.5-inch LCD
Akụkụ (LxWxH)170x196x118mm (device) / 290x196x134mm (with H60 humidifier)
Ibu<1.5kg (device) / <2.5kg (with H60 humidifier)
Ịnye ọkụInput Range 100-240V AC, 50/60 Hz, 2.0 A max
Nchekwa dataSD Card (iCode II)
Mba onye siChina

9. Akwụkwọ ikike na nkwado

For warranty information, please refer to the documentation provided with your purchase or contact your retailer. For technical support, service, or questions regarding your BMC RESmart GII Auto CPAP System, please contact the seller or the manufacturer directly.

© 2023 BMC. All rights reserved. This manual is for informational purposes only.