Aux ASW-12A2/FFR1

Aux ASW-12A2/FFR1 Conventional Mini-Split Air Conditioner User Manual

Model: ASW-12A2/FFR1 | Brand: Aux

1. Okwu mmalite

This manual provides detailed instructions for the installation, operation, and maintenance of your Aux ASW-12A2/FFR1 Conventional Mini-Split Air Conditioner. Please read this manual thoroughly before using the appliance to ensure proper function and safety. Keep this manual for future reference.

2. Ozi nchekwa

Na-agbaso ihe ndị a dị mkpa mgbe niile iji belata ihe egwu nke ọkụ eletrik, ọkụ, ma ọ bụ mmerụ ahụ.

  • Installation must be performed by qualified personnel in accordance with local and national electrical codes.
  • Hụ na ọkọnọ ike ahụ dabara na ihe achọrọ na nkeji ahụ (220V).
  • Do not operate the unit with wet hands or when standing on a wet surface.
  • Etinyela ihe n'ime oghere ikuku ma ọ bụ n'ọnụ ụzọ mbata.
  • Gbanyụọ ọkụ ọkụ tupu ihicha ma ọ bụ ịrụ ọrụ ọ bụla.
  • Debe ụmụaka pụọ ​​na ngalaba.
  • Anwala ịrụkwa unit ahụ n'onwe gị. Kpọtụrụ ndị ọrụ ruru eru.
  • Gbaa mbọ hụ na ntọ ala kwesịrị ekwesị iji gbochie ujo ọkụ eletrik.

3. Ngwaahịa gafereview

3.1 Akụkụ

The Aux ASW-12A2/FFR1 Mini-Split system consists of two main units:

  • Indoor Unit (Evaporator): Mounted inside the room, responsible for air circulation and temperature exchange.
  • Outdoor Unit (Condenser): Mounted outside, responsible for heat dissipation.
  • Njikwa anya: A na-eji ya arụ ọrụ na nhazi ntọala.

3.2 Ọrụ njikwa anya

The remote control allows you to manage all functions of your mini-split unit. Familiarize yourself with the buttons and their corresponding actions.

Aux Mini-Split Air Conditioner Remote Control

Foto 1: Aux Mini-Split Air Conditioner Remote Control. This image displays the white remote control with a grey LCD screen at the top. Below the screen, the 'AUX' logo is visible. The buttons are light green, with a central blue power button. Key buttons include MODE, SPEED, SWING (horizontal and vertical), TURBO, TIMER, iFavor, iFeel, HEALTH, SLEEP, iClean, Anti-FUNGUS, and DISPLAY.

  • Power Button (Blue): Gbanyụọ otu ahụ ma ọ bụ gbanyụọ.
  • bọtịnụ Celsius C/F: Switches temperature display between Celsius and Fahrenheit.
  • Bọtịnụ MODE: Na-agbagharị site na ụdị ọrụ (dịka ọmụmaatụ, Oyi, Okpomọkụ, Fan, Akọrọ, na Akpaaka).
  • Bọtịnụ Mgbanwe Okpomọkụ (Akụ Elu/Ada): Na-eme ka okpomọkụ dị elu ma ọ bụ na-ebelata.
  • Bọtịnụ Ọsọ: Na-agbanwe ọsọ fan (Ọ dị ala, Ọkara, Elu, Akpaaka).
  • SWING ←→ Button: Controls the horizontal louver swing.
  • SWING ↑↓ Button: Controls the vertical louver swing.
  • Bọtịnụ TURBO: Na-eme ka oyi ma ọ bụ ikpo ọkụ dị ngwa ngwa rụọ ọrụ ruo obere oge.
  • Bọtịnụ TIMER: Na-edobe oge ịgbanwuo ma ọ bụ gbanyụọ akpaaka.
  • iFavor Button: Activates a personalized preferred setting.
  • iFeel Button: Activates the remote control's built-in temperature sensor for more precise room temperature control.
  • HEALTH Button: Activates air purification or health-related functions.
  • Bọtịnụ Ụra: Na-edozi okpomọkụ na ọsọ fan maka ụra dị mma.
  • iClean Button: Initiates the self-cleaning function of the indoor unit.
  • Anti-FUNGUS Button: Activates the anti-fungus function to prevent mold growth.
  • DISPLAY Button: Turns the indoor unit's display ON or OFF.

4. Ntọala na nwụnye

The Aux ASW-12A2/FFR1 is a split-system air conditioner requiring professional installation. Incorrect installation can lead to water leakage, electric shock, or fire. Do not attempt to install the unit yourself.

4.1 Nyochaa nwụnye tupu etinye ya

  • Ensure the installation site can support the weight of both indoor and outdoor units.
  • Verify that the electrical supply is 220V and has appropriate circuit protection.
  • Confirm adequate space for air circulation around both units.

4.2 Ngwa ntinye

The unit typically includes an installation kit with 3 meters of copper/aluminum piping and 3.5 meters of electrical cable for connecting the indoor and outdoor units.

4.3 Nwụnye ọkachamara

Contact a certified HVAC technician for installation. They will handle:

  • Mounting the indoor and outdoor units.
  • Connecting refrigerant lines and electrical wiring.
  • Ensuring proper drainage for condensate.
  • Vacuuming the refrigerant lines and charging with R410-A refrigerant (680g pre-charged).
  • Testing the system for leaks and proper operation.

5. Ntuziaka ọrụ

Use the remote control to operate your Aux mini-split unit.

5.1 Basic Arụmọrụ

  1. Gbanyụọ/ Gbanyụọ: Press the blue Power button on the remote control.
  2. Họrọ Ụdị: Press the MODE button repeatedly to cycle through available modes:
    • dị jụụ: Maka ime ụlọ ahụ jụrụ oyi.
    • Okpomọkụ: Maka ikpo ọkụ ụlọ ahụ.
    • Onye ofufe: Maka mgbasa ikuku na-enweghị oyi ma ọ bụ kpo oku.
    • Akọrọ: Maka iwepụ mmiri mmiri.
    • Akpaaka: Ngalaba ahụ na-ahọrọ ọnọdụ ọrụ na-akpaghị aka dabere na okpomọkụ ụlọ.
  3. Tọọ okpomọkụ: Use the Up/Down arrow buttons to adjust the desired temperature. The unit has a cooling capacity of 12,000 BTUs.
  4. Gbanwee ọsọ onye ofufe: Press the SPEED button to select fan speed (Auto, Low, Medium, High).
  5. Gbanwee ntụzịaka ikuku: Use the SWING ←→ and SWING ↑↓ buttons to control the horizontal and vertical louver movement.

5.2 Ọrụ dị elu

  • TURBO: For rapid cooling or heating. Press this button to quickly reach the desired temperature.
  • Oge: Set a timer for the unit to automatically turn on or off. Refer to the remote control's specific instructions for detailed timer settings.
  • mmetụta: Activates the temperature sensor in the remote control, allowing the unit to adjust its operation based on the temperature at the remote's location, providing personalized comfort.
  • Ụra: Optimizes temperature and fan speed for a comfortable sleeping environment, often increasing the temperature slightly during cooling mode or decreasing it during heating mode over time. This also includes the "display on-off" feature for quality rest.
  • iClean / Anti-FUNGUS: These functions contribute to maintaining a clean and healthy indoor unit by preventing mold and bacteria growth.
  • Ngosi: Toggles the LED display on the indoor unit ON or OFF for undisturbed rest.
  • Malitegharịa na akpaghị aka: Ọ bụrụ na ike gịtage, unit ga-amalite na-akpaghị aka na mbụ ntọala ozugbo ike eweghachiri.

6. Nlekọta

Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner. Always disconnect power before performing maintenance.

6.1 Nchacha ikuku ikuku

  • Na-asachapụ ihe nzacha ikuku kwa izu abụọ ma ọ bụ karịa ugboro ugboro ma ọ bụrụ na ejiri nkeji ahụ nke ukwuu ma ọ bụ na gburugburu uzuzu.
  • Open the front panel of the indoor unit and remove the filters.
  • Wash filters with lukewarm water and a mild detergent. Rinse thoroughly and allow them to dry completely before reinserting.

6.2 Nchacha otu

  • Jiri nro dị nro hichaa akụkụ ime ụlọ na n'èzí, damp akwa . Ejila kemịkalụ siri ike ma ọ bụ ihe mkpocha abrasive.
  • Jiri ya iClean na Anti-FUNGUS functions regularly to help maintain the cleanliness of the indoor coil and prevent mold growth.

6.3 Ọrụ Ndị ọkachamara

Schedule annual professional servicing to check refrigerant levels, clean coils, and inspect electrical connections for optimal performance and safety.

7. Nchọpụta nsogbu

Tupu ịkpọtụrụ ọrụ, lelee nsogbu ndị a na-ahụkarị:

NsogbuIhe nwere ike imeNgwọta
Unit anaghị agbanwuoEnweghị ike, batrị dịpụrụ adịpụ dị ala, ihe mgbawa sekit adaala.Lelee ọkọnọ ike, dochie batrị ndị dịpụrụ adịpụ, tọgharịa ihe mgbawa sekit.
Ezughi oke jụrụ oyi/ọkụDirty air filters, blocked outdoor unit, wrong mode selected, doors/windows open.Clean filters, clear obstructions, select correct mode, close openings.
Mkpọtụ na-adịghị ahụkebeLoose parts, foreign objects, unit not level.Check for loose parts, remove objects, ensure unit is level. If noise persists, contact service.
Mwepu mmiri sitere na nkeji ime ụlọBlocked drain pipe, improper installation.Lelee ma hichaa paịpụ mmiri. Ọ bụrụ na nsogbu ahụ anọgide, kpọtụrụ ọkachamara na-etinye ya.

Ọ bụrụ na nsogbu ahụ anọgide mgbe ị nwalechara ngwọta ndị a, biko kpọtụrụ ndị ọrụ ruru eru.

8. Nkọwapụta

Technical specifications for the Aux ASW-12A2/FFR1 Mini-Split Air Conditioner:

  • Aha nlereanya: ASW-12A2/FFR1
  • Akara: Aux
  • Ụdị: Conventional Mini-Split
  • Ike jụrụ oyi: 12,000 British Thermal Units (BTU)
  • Voltage: 220 volts
  • Isi mmalite ike: Igwe ọkụ eletrik
  • Wattage: 3200 W (Cooling) – 1175 W (Heating)
  • Igwe nju oyi: R410-A (Ecological), 680g pre-charged
  • Indoor Noise Level: 41 dB
  • Outdoor Noise Level: 50 dB
  • Ofufe ikuku: 600m³/h
  • Motor RPM (H/M/L): 1230/950/800
  • Usoro njikwa: Remote Control (with iFeel sensor)
  • Ụdị Compressor: Rotary Scroll
  • Atụmatụ pụrụ iche: Heating and Cooling Function, Auto-Restart, Self-Cleaning (iClean), Anti-Fungus, Sleep Mode (Display On-Off), iFeel, iFavor.
  • Ụzọ ntinye: Split System (requires outdoor unit)
  • Arọ ngwaahịa: 39500 Grams (39.5 n'arọ)
  • Ihe ndị gụnyere: Evaporator (Indoor Unit), Condenser (Outdoor Unit)

9. Akwụkwọ ikike na nkwado

9.1 Ozi akwụkwọ ikike

This Aux ASW-12A2/FFR1 Mini-Split Air Conditioner comes with a Akwụkwọ ikike nwere oke. Please refer to the warranty card included with your product for specific terms, conditions, and duration of coverage. Keep your purchase receipt as proof of purchase for warranty claims.

9.2 Nkwado ndị ahịa

For technical assistance, service requests, or warranty inquiries, please contact Aux customer support. Contact information can typically be found on the manufacturer's websaịtị ma ọ bụ na nkwakọ ngwaahịa.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.