BWT 812195

BWT Aquameter LF Water Filter Meter 3/8" Instruction Manual

Ụdị: 812195

Okwu mmalite

The BWT Aquameter LF (Low Flow) is designed to precisely monitor the volume of water that has passed through your water filter system. This device helps ensure timely filter replacement, maintaining optimal water quality for applications such as espresso machines. It features an LCD display for real-time capacity tracking and is compatible with various BWT water filters, including Bestmax and Besttaste series.

Ngwaahịa gafereview

BWT Aquameter LF control unit and flow sensor

Foto 1: BWT Aquameter LF control unit with LCD display and separate flow sensor, connected by a cable. This image shows the main components of the Aquameter LF system.

BWT Aquameter LF product packaging

Foto 2: The packaging for the BWT Aquameter LF, indicating its 3/8" connection and NSF certification. The packaging also displays the product number 812136 and GTIN 04250266700169.

Ntọala na nwụnye

  1. Wepu akụrụngwa: Carefully remove the BWT Aquameter LF control unit, flow sensor, and connecting cable from the packaging.
  2. Chọpụta ụzọ na-aga: The flow sensor has an arrow indicating the direction of water flow. Ensure this aligns with your water line.
  3. Connect Flow Sensor: Install the 3/8" flow sensor into the water line before your BWT water filter. Use appropriate plumbing fittings to ensure a secure, leak-free connection.
    BWT Aquameter LF installed with water filter

    Foto 3: The BWT Aquameter LF control unit mounted on a wall, connected to a BWT Bestmax water filter installed under a sink. This illustrates a typical installation setup.

  4. Jikọọ Ngalaba njikwa: Plug the cable from the flow sensor into the designated port on the BWT Aquameter LF control unit.
  5. Ngalaba Njikwa Ugwu: Mount the control unit in a convenient location using the provided mounting hardware. Ensure the display is easily visible.
    Close-up of BWT Aquameter LF control unit installed

    Foto 4: A nso-elu view of the BWT Aquameter LF control unit mounted, showing the LCD display, "PROG." and "RESET" buttons, and the CE mark. The cable connecting to the flow sensor is visible.

  6. Mmemme izizi:
    • Press and hold the "PROG." button to enter programming mode.
    • Use the "PROG." button to cycle through settings (e.g., total filter capacity in liters).
    • Use the "RESET" button to adjust the values for each setting.
    • Confirm settings by pressing "PROG." again or waiting for the unit to exit programming mode automatically.
    • Set the filter capacity according to your specific BWT filter model and local water hardness.

Ntuziaka ọrụ

  • Monitoring Water Volume: The LCD display continuously shows the remaining filter capacity in liters. As water flows through the filter, the displayed value decreases.
  • Ihe ngosi nnọchi nzacha: When the displayed capacity reaches a low level or zero, it indicates that the water filter needs to be replaced. Refer to your specific BWT filter's documentation for recommended replacement intervals.
  • Resetting the Meter: After replacing the water filter, press and hold the "RESET" button for at least 3 seconds to reset the meter to its programmed initial capacity. This action ensures accurate tracking for the new filter.

Nlekọta

  • Ndochi nzacha: Regularly replace your BWT water filter according to the manufacturer's recommendations or when the Aquameter LF indicates zero remaining capacity. This ensures continued water quality and system performance.
  • Nhicha: Wipe the exterior of the Aquameter LF control unit with a soft, damp akwa . Ejila ihe nchacha abrasive ma ọ bụ ihe mgbaze.
  • Ngbanwe batrị: The Aquameter LF operates on internal batteries. If the display becomes dim or unresponsive, the batteries may need replacement. Consult a qualified technician or BWT support for battery replacement procedures.

Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Ngosipụta bụ oghere ma ọ bụ nchara nchara.Batrị ndị dị ala ma ọ bụ ndị na-agwụ ike.Contact BWT support for battery replacement.
Capacity not decreasing.Flow sensor incorrectly installed or faulty. No water flow detected.Check flow sensor installation, ensuring correct flow direction. Verify water flow through the system.
Incorrect capacity reading after filter change.Meter not reset after filter replacement.Press and hold the "RESET" button for 3 seconds to reset the meter.
Water leakage at connections.Loose fittings or improper sealing.Ensure all plumbing connections are tight and properly sealed with appropriate thread sealant or tape.

Nkọwapụta

  • Nọmba nlereanya: 812195
  • Ihe: Acrylonitrile Butadiene Styrene (ABS)
  • Akụkụ ngwaahịa: 2.4"D x 4.8"W x 4.1"H
  • Flow Rate (Low Flow): 10–100 liters/hour
  • Nha Njikọ: 3/8"
  • Ibu ihe: 7 ounces
  • External Testing Certification: NSF
  • Compatible Water Purifier Models: BWT Bestmax, BWT Bestmax PREMIUM, BWT Besttaste
  • Nọmba njirimara azụmaahịa zuru ụwa ọnụ (GTIN): 04250266700169

Ozi akwụkwọ ikike

For detailed warranty information regarding your BWT Aquameter LF, please refer to the warranty card included with your product or visit the official BWT websaịtị. Usoro na ọnọdụ ikike nwere ike ịdị iche site na mpaghara.

Nkwado

If you require further assistance, technical support, or have questions about your BWT Aquameter LF, please contact BWT customer service or visit the official BWT store online.

Visit the BWT Store on Amazon

© 2024 BWT. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.