ABB S203-B16

ABB S203-B16 Miniature Circuit Breaker User Manual

Model: S203-B16

1. Ngwaahịa gafereview

The ABB S203-B16 is a low voltage, 3-pole miniature circuit breaker designed for equipment protection. It features a 480Y/277 VAC voltage rating, a 16 A amperage rating, and an interrupt rating of 6 kA.

This device incorporates thermal/magnetic trip mechanisms for reliable overcurrent fault protection in various applications, including commercial appliances, control circuits, and computer equipment.

ABB S203-B16 Miniature Circuit Breaker front view

Foto 1: N'ihu view of the ABB S203-B16 Miniature Circuit Breaker, showing the toggle switch and model markings.

2. Ozi nchekwa

Always adhere to local electrical codes and regulations during installation and operation. Installation should only be performed by qualified personnel.

  • Gbaa mbọ hụ na agbapụrụ ike tupu echichi ma ọ bụ mmezi.
  • Ejila ihe mgbawa sekit ahụ rụọ ọrụ ma ọ bụrụ na o yie ka ọ mebiri emebi.
  • Yiri akụrụngwa nchedo onwe onye dabara adaba (PPE).
  • Refer to the wiring diagrams for correct connections.

3. Ntọala na nwụnye

The S203-B16 circuit breaker is designed for DIN-rail mounting.

  1. Ịkwanye: Securely attach the circuit breaker to a standard DIN-rail. Ensure the mounting clip engages properly.
  2. Wiring: Connect the electrical conductors to the screw terminals. The wire size supported is 18 - 4 AWG for conductors and 18 - 8 AWG for busbars.
  3. Imechi ọnụ ọnụ: Ensure all screw terminals are tightened to the specified torque to prevent loose connections and overheating.
N'azụ view of circuit breaker showing DIN-rail clip

Ọgụgụ 2: N'azụ view illustrating the DIN-rail mounting mechanism.

N'elu view of circuit breaker terminals

Foto 3: Top view showing the input terminals of the circuit breaker.

N'okpuru view of circuit breaker terminals

Onyonyo 4: N'okpuru view showing the output terminals of the circuit breaker.

4. Ntuziaka ọrụ

The ABB S203-B16 circuit breaker is operated via a toggle actuator.

  • Ka ịgbanwuo: Push the toggle actuator upwards to the "ON" position.
  • Gbanyụọ: Push the toggle actuator downwards to the "OFF" position.
  • Trip Indication: In case of an overcurrent or short circuit, the toggle actuator will automatically move to an intermediate "TRIPPED" position.
  • Resetting After Trip: To reset the circuit breaker after a trip, first move the toggle completely to the "OFF" position, then push it upwards to the "ON" position. Investigate the cause of the trip before resetting.

5. Nlekọta

The ABB S203-B16 circuit breaker requires minimal maintenance. Regular inspections are recommended to ensure proper function and safety.

  • Nlele anya: Lelee ihe mgbawa sekit ahụ mgbe niile maka ihe ịrịba ama ọ bụla nke mmebi anụ ahụ, mgbanwe agba, ma ọ bụ njikọ ndị na-adịghị mma.
  • Nhicha: If necessary, clean the exterior of the circuit breaker with a dry, lint-free cloth. Do not use abrasive cleaners or solvents.
  • Lelee njedebe: Verify that all terminal connections remain tight.
  • Ọnọdụ gburugburu: Ensure the operating environment remains within the specified temperature range (-25 to 55 deg C) and IP20 enclosure rating.

6. Nchọpụta nsogbu

NsogbuIhe nwere ike imeNgwọta
Ọ na-agbagharị ugboro ugboro.Overload, short circuit, or faulty appliance/wiring.Reduce load, check for short circuits, inspect connected equipment and wiring.
Ihe mgbawa sekit anaghị emegharị.Persistent fault, internal damage.Ensure the fault is cleared. If it still doesn't reset, the unit may be damaged and require replacement. Consult a qualified electrician.
Ihe mgbawa sekit na-adị ọkụ.Overload, loose connections, or internal fault.Reduce load, check terminal tightness, or replace the unit if overheating persists without apparent cause.

If troubleshooting steps do not resolve the issue, contact a qualified electrician or ABB customer support.

7. Nkọwapụta

NjirimaraNkọwa
NlereanyaS203-B16
ỤdịVol dị alatage Miniature Circuit Breaker
Ọnụ ọgụgụ okporo osisi3
Voltage Ntụle480Y/277 VAC
Ampogo erage16 A
Ogo ugboro ugboro50/60 Hz
Nledo nkwụsị6 ka
Ụdị njemThermal/Magnetic
Ogologo njem3 - 5 A Magnetic and 1.13 - 1.45 A Thermal
Ụdị ActuatorTụgharịa
Ogo waya18 - 4 AWG Conductor, 18 - 8 AWG Busbar
Ụdị njedebeỊghasa
Ụdị mkpuchiIP20
Ụdị nkwụnyeDIN-okporo ígwè
Ọnụọgụ okpomọkụ-25 ka 55 Celsius C
Akụkụ88 mm Height x 52-1/2 mm Width x 69 mm Depth
Ihe onwunweKpụrụ Plastic
Standards/ApprovalsIEC/EN 60898-1, IEC/EN 60947-2, UL 1077, CSA 22.2
Akụkụ view of circuit breaker with certifications

Foto 5: Akụkụ view displaying product specifications and international certifications.

Akụkụ view of circuit breaker with barcode

Foto 6: Akụkụ view showing the product barcode and manufacturing details.

8. Akwụkwọ ikike Ozi

For detailed warranty information regarding your ABB S203-B16 Miniature Circuit Breaker, please refer to the official ABB warranty policy available on the manufacturer's website or contact ABB customer service directly. Keep your purchase receipt as proof of purchase.

9. Nkwado ndị ahịa

If you require technical assistance, have questions about installation, operation, or maintenance, please contact ABB customer support.

  • ABB Official Websaịtị: www.abb.com
  • Nkwado ndị teknuzu: Refer to the support section on the ABB website for contact numbers and online resources specific to your region.

© 2023 ABB. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.