1. Okwu mmalite
Thank you for choosing the EIBENSTOCK DSS 35 M iP Industrial Vacuum Cleaner. This robust and durable industrial vacuum is designed for efficient dust and debris extraction in professional environments. This manual provides essential information for the safe and effective operation, setup, maintenance, and troubleshooting of your device. Please read these instructions carefully before initial use and keep them for future reference.

Figure 1: EIBENSTOCK DSS 35 M iP Industrial Vacuum Cleaner, front-left view with hose connection.
2. Ntuziaka nchekwa
Always observe the following safety precautions to prevent electric shock, injury, or fire:
- Nchekwa Eletriki: Gbaa mbọ hụ na ọkọnọ ike dabara na voltage specified on the vacuum cleaner. Do not operate with a damaged power cord or plug.
- Ojiji nke ọma: This vacuum cleaner is designed for industrial use to extract dry and wet non-flammable materials. Do not vacuum flammable liquids, explosive dusts, or hot materials.
- Ngwa nchekwa nkeonwe: Wear appropriate personal protective equipment (PPE) such as safety glasses and dust masks, especially when dealing with fine dust.
- Nlekọta: Ahapụla igwe na-ehicha ihe n'echeghị ya mgbe ọ na-arụ ọrụ.
- Nlekọta: Disconnect the power plug before performing any maintenance, cleaning, or filter changes.
- Nkwụsi ike: Ensure the vacuum cleaner is placed on a stable, level surface during operation to prevent tipping.
3. Ngwaahịa gafereview
Familiarize yourself with the main components and controls of your EIBENSTOCK DSS 35 M iP industrial vacuum cleaner.

Figure 2: Control panel with power switch, suction power adjustment, and Permanent Clean indicator.
Isi ihe:
- Isi ngalaba: Houses the motor, dust container, and filter system.
- Ogwe njikwa: Located on top, includes power switch, suction control, and filter cleaning functions.
- Njikọ Hose: Port for attaching the suction hose.
- Wheels/Casters: Maka mfe ịkwaga.
- Akpa uzuzu: Collects vacuumed material.
- Sistemụ nzacha: Includes a permanent filter for efficient dust separation.
4. Nhazi
Follow these steps to prepare your vacuum cleaner for operation:
- Iwepu: Jiri nlezianya wepụ ihe niile dị na ngwugwu ahụ. Lelee ma ọ bụrụ na e mebiri ihe ọ bụla.
- Ntinye nyocha: Ensure the permanent filter is correctly seated in its compartment. Refer to the maintenance section for filter access.
- Njikọ Hose: Attach the suction hose securely to the designated inlet port on the front of the vacuum cleaner.
- Ngwa mgbakwunye: Connect the desired nozzle or accessory to the end of the suction hose.
- Njikọ ike: Tinye eriri ọkụ n'ime oghere eletrik kwesịrị ekwesị (230V).
5. Ntuziaka ọrụ
Operating the EIBENSTOCK DSS 35 M iP is straightforward:

Figure 3: Industrial vacuum cleaner connected to a power tool for dust extraction.
- Ike Na: Turn the main power switch on the control panel to the 'ON' position.
- Ndozi mmiri: Use the rotary knob on the control panel to adjust the suction power as needed for the task.
- Permanent Clean System: The DSS 35 M iP features an automatic 'Permanent Clean' filter cleaning system. This system periodically cleans the filter during operation to maintain optimal suction performance. An indicator light may signal its activity.
- Tool Connection (if applicable): If using with a power tool, connect the tool's dust extraction port to the vacuum hose. The vacuum may have an integrated power outlet for synchronized operation.
- Ọrụ: Begin vacuuming the desired area or material.
- Gbanyụọ: After use, turn the main power switch to the 'OFF' position and unplug the unit from the power supply.
6. Nlekọta
Mmezi mgbe niile na-eme ka igwe nhicha ikuku gị dị ogologo ma na-arụ ọrụ nke ọma.

Figure 4: Accessing and removing the permanent filter for cleaning or replacement.
Nhicha na Ndochi Nzacha:
- Ugboro: The permanent filter should be inspected and cleaned regularly, depending on the intensity of use and the type of material vacuumed. The 'Permanent Clean' system helps, but manual inspection is still necessary.
- Nweta: Disconnect the power. Open the filter compartment (refer to the product diagram or manufacturer's specific instructions for your model).
- Nhicha: Carefully remove the filter. Tap it gently to dislodge dust or use compressed air (from the clean side) to blow out fine particles. Do not wash the filter unless explicitly stated by the manufacturer.
- Ndochi: If the filter is damaged or excessively clogged and cannot be cleaned effectively, replace it with an original EIBENSTOCK permanent filter (part number 9919000-FILTER, if available).
Dust Container Emptying:
- Ugboro: Empty the dust container when it reaches its maximum capacity (25 liters net) or when suction power noticeably decreases.
- Usoro: Disconnect the power. Unlatch and remove the top section of the vacuum cleaner. Carefully lift out the dust container and dispose of its contents according to local regulations. Clean the container if necessary.
Nchacha izugbe:
- Jiri mgbasa ozi hichapụ mpụta ihe mkpofuamp akwa . Ejila kemịkalụ siri ike ma ọ bụ ihe mkpocha abrasive.
- Check hoses and accessories for blockages or damage.
7. Nchọpụta nsogbu
If you encounter issues with your EIBENSTOCK DSS 35 M iP, consult the table below for common problems and solutions.
| Nsogbu | Ihe nwere ike ime | Ngwọta |
|---|---|---|
| Vacuum anaghị agbanye | Enweghị ọkụ eletrik; Eriri/plọg eletrik mebiri emebi; Mgbanwe adịghị mma | Check power outlet and plug; Inspect power cord; Contact service if switch is faulty. |
| Ike mmiri dị ala | Clogged filter; Full dust container; Blocked hose/nozzle; Air leak | Clean/replace filter; Empty dust container; Clear blockages; Check all connections for leaks. |
| Mkpọtụ na-adịghị ahụkebe n'oge arụ ọrụ | Foreign object in fan/motor; Motor issue | Disconnect power and inspect for foreign objects (if safe); Contact service. |
| Já na -agbapụ na oghere | Filter not properly seated; Damaged filter; Container not sealed | Ensure filter is correctly installed; Replace damaged filter; Check container seals. |
If the problem persists after attempting these solutions, please contact EIBENSTOCK customer support or an authorized service center.
8. Nkọwapụta
Technical data for the EIBENSTOCK DSS 35 M iP Industrial Vacuum Cleaner:
- Ụdị: DSS 35 M iP
- Nọmba ntụaka: 9919000
- Ntinye ike: 1600 W
- Voltage: 230 V
- Tank Volume (Gross): 35 lita
- Dust Volume (Net): 25 lita
- Oke ikuku ikuku: 64 l / s
- Oke Vacuum mgbali: 259mbar
- Akụkụ (L x W x H): 55 x 40 x 55 cm
- Arọ: 15 n'arọ
- Isi mmalite ike: Igwe ọkụ eletrik
- Njirimara Pụrụ Iche: Permanent Clean Filter System, Increased Dust Capacity
- Ngwa gụnyere: Filter na-adịgide adịgide
9. Akwụkwọ ikike na nkwado
For warranty information, please refer to the warranty card included with your product or contact your point of purchase. EIBENSTOCK provides support for its products. For technical assistance, spare parts, or service inquiries, please visit the official EIBENSTOCK website or contact their customer service department directly. Always provide the model number (DSS 35 M iP) and reference number (9919000) when seeking support.