RAB Lighting FFLED39

RAB Lighting FFLED39 Future Flood LED Light User Manual

Model: FFLED39

1. Ngwaahịa gafereview

The RAB Lighting FFLED39 Future Flood LED Light is a high-performance, energy-efficient outdoor floodlight designed for various applications. This hardwired fixture features a durable bronze finish and provides cool white illumination.

RAB Lighting FFLED39 Future Flood LED Light

Figure 1: RAB Lighting FFLED39 Future Flood LED Light

Akụkụ ndị bụ isi:

  • Ike: 39-watt LED
  • Okpomọkụ agba: 5100K Cool White
  • Ogologo ndụ: 100,000 hours based on LM-80 tests
  • Ọkụ: Three multi-chip 13-watt high-performance LEDs
  • Gbasara Anya: NEMA type 7H x 6V with Air-flow technology heatsink
  • Ntụleghachi: Semi-specular anodized aluminum
  • Mpempe akwụkwọ: silicone dị elu
  • Mechaa: Bronze chip and fade-resistant polyester powder coat
  • Voltage: 120-volt to 277-volt operation

2. Ozi nchekwa

Gụọ ntuziaka niile nke ọma tupu echichi ma ọ bụ rụọ ọrụ. Ọ bụrụ na ị gbasoghị ntuziaka ndị a, ọ nwere ike ibute ujo eletriki, ọkụ, ma ọ bụ ihe egwu ndị ọzọ. Debe akwụkwọ ntuziaka a maka ntụaka n'ọdịnihu.

  • Nchekwa Eletriki: Installation must be performed by a qualified electrician in accordance with all national and local electrical codes. Ensure power is disconnected at the circuit breaker before installation or servicing.
  • Nda ala: The fixture must be properly grounded to prevent potential electric shock.
  • Ịkwanye: Ensure the mounting surface is structurally sound and capable of supporting the fixture's weight (approximately 10.23 lbs).
  • Okpomọkụ arụ ọrụ: Do not operate the fixture outside its specified temperature range.
  • Ọkụ: Do not stare directly into the LED light source when the fixture is operating, as this may cause eye damage.

3. Nwụnye

This floodlight is designed for wall mounting and requires hardwired installation. Professional installation is recommended.

Ngwa achọrọ:

  • Screwdriver (Phillips na flathead)
  • Waya waya
  • Pliers
  • Drill (if mounting surface requires pilot holes)
  • mgbanaka nwere ike idozi

Nhọrọ nkwụnye:

The FFLED39 supports various mounting options. The standard fixture comes with a wall mount. Optional accessories may include slipfitter mounts or other specialized brackets.

Slipfitter mount for RAB Lighting FFLED39

Ọgụgụ 2: Ọpụample of a Slipfitter Mount (optional accessory)

Nzọụkwụ nwụnye:

  1. Kwụpụ ike: Turn off power at the circuit breaker before beginning installation. Verify power is off using a voltagọ bụ onye nyocha.
  2. Kwadebe elu elu: Securely attach the mounting bracket to the desired wall location. Ensure the bracket is level and firmly fastened.
  3. Njikọ waya:
    • Connect the black wire from the fixture to the hot (L) wire from the power supply.
    • Connect the white wire from the fixture to the neutral (N) wire from the power supply.
    • Connect the green or bare copper wire from the fixture to the ground wire from the power supply.
    • Use appropriate wire connectors and ensure all connections are secure.
  4. Ndozi Ugwu: Attach the FFLED39 fixture to the mounting bracket. Secure it with the provided screws or bolts.
  5. Gbanwee ebumnuche: Loosen the adjustment screws on the fixture to aim the light as desired. Tighten the screws firmly once the desired angle is achieved.
  6. Weghachi ike: Turn on power at the circuit breaker. Test the fixture for proper operation.

4. Ọrụ

The RAB Lighting FFLED39 is a hardwired floodlight. Its operation is typically controlled by an external switch or a photocell (if installed).

Ọrụ ọkọlọtọ:

  • Once installed and wired, the fixture will illuminate when power is supplied via the connected wall switch or control system.
  • Ensure the power source is within the specified 120-277V range.

Photocell Control (Optional):

If a photocell is integrated or installed with the fixture, the light will automatically turn on at dusk and off at dawn, based on ambient light levels.

Photocell for automatic light control

Ọgụgụ 3: Ọpụample of a Photocell (optional accessory)

5. Nlekọta

The FFLED39 LED floodlight is designed for minimal maintenance due to its long-life LED components and durable construction.

Nhicha:

  • Mputa: Na-eji nwayọọ na-ehicha mpụta nke ihe ndozi ahụ, damp cloth to remove dirt, dust, and debris. Do not use abrasive cleaners or solvents.
  • oghere: Gently wipe the lens with a clean, soft cloth to ensure maximum light output.

Nyocha:

  • Lelee ngwa ngwa maka akara ọ bụla mebiri emebi, njikọ rụrụ arụ, ma ọ bụ eyi.
  • Ensure all mounting hardware remains tight and secure.
  • If any damage is observed, disconnect power and contact a qualified electrician for repair or replacement.

6. Nchọpụta nsogbu

If you experience issues with your FFLED39 floodlight, refer to the following troubleshooting guide:

NsogbuIhe nwere ike imeNgwọta
Ìhè anaghị agbanwuo
  • Enweghị ike maka nrụnye
  • Njikọ waya na-adịghị mma
  • Faulty switch or circuit breaker
  • Photocell malfunction (if applicable)
  • Lelee ihe mgbawa sekit na mgba ọkụ mgbidi.
  • Hụ na njikọ waya niile dị nchebe (hụ na agbanyụrụ ọkụ mbụ).
  • Test switch/breaker; replace if faulty.
  • Inspect photocell for obstructions or damage; replace if necessary.
Ìhè flickers ma ọ bụ na-ada ada
  • Ọkụ ọkụ anaghị akwụsi ike
  • Ngwa ngwa waya
  • Incompatible dimmer (if used)
  • Gakwuru onye ọrụ ọkụ eletrik iji lelee otú ọkụ eletrik si dị.
  • Lelee ma mee ka njikọ waya niile sie ike.
  • Ensure any dimmer switch used is compatible with LED fixtures.
Ìhè na-anọ n'ehihie
  • Photocell obstructed or faulty
  • Incorrect wiring of photocell
  • Clear any obstructions from the photocell.
  • Verify photocell wiring according to its instructions. Replace if faulty.

If the problem persists after following these steps, contact RAB Lighting customer support or a qualified electrician.

7. Nkọwapụta

Detailed technical specifications for the RAB Lighting FFLED39 Future Flood LED Light:

NkọwapụtaUru
Nọmba nlereanyaFFLED39
ỤdịRAB ọkụ
Wattage39 watt
Voltage120-277 volts
Isi Iyi ÌhèIkanam
Agba ọkụỌcha dị jụụ
Okpomọkụ agba5100 Kelvin
Icha ọkụ15000 Lumen
Ojiji ime ime/n'èzíN'èzí
Ụdị nkwụnyeUgwu mgbidi
Ihe onwunweAluminom, plastic
Ụdị mmechaỌla
Akụkụ ihe (L x W x H)11"L x 7.5"W x 10"H
Ibu Ibu10.23 pound
Ọkwa Nguzogide mmiriMmiri na-eguzogide
Ogologo ndụawa 100,000
100,000-hour LED lifespan icon

Figure 4: Indication of 100,000-hour LED lifespan

8. Akwụkwọ ikike na nkwado

Akwụkwọ ikike nke onye nrụpụta:

The RAB Lighting FFLED39 Future Flood LED Light is covered by a Akwụkwọ ikike onye nrụpụta afọ 1 site na ụbọchị azụrụ ya. Akwụkwọ ikike a na-ekpuchi ntụpọ dị na ihe na ọrụ aka n'okpuru ojiji na ọrụ nkịtị.

The warranty does not cover damage resulting from improper installation, accident, misuse, abuse, negligence, or unauthorized modification or repair.

Nkwado ndị ahịa:

For technical assistance, warranty claims, or further information, please contact RAB Lighting customer support. Refer to the official RAB Lighting websaịtị maka nkọwa kọntaktị ugbu a.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.