PeakTech P 6145

PeakTech P 6145 Digital Double Laboratory Power Supply

Akwụkwọ ntuziaka onye ọrụ

1. Okwu mmalite

The PeakTech P 6145 is a high-quality, stabilized digital double laboratory power supply designed for various applications requiring precise and reliable DC voltage and current. It features two independent, linearly adjustable outputs (0-30V / 0-5A DC) and an additional fixed 5V / 3A output. This manual provides essential information for the safe and efficient operation of your device.

N'ihu view of the PeakTech P 6145 Digital Double Laboratory Power Supply

Foto 1.1: N'ihu view of the PeakTech P 6145 Digital Double Laboratory Power Supply, showing the dual digital displays for voltage and current, and control knobs for each channel.

2. Ntuziaka nchekwa

Before operating the device, please read and understand all safety instructions. Failure to comply may result in injury or damage to the equipment.

  • Hụ na ejikọtara ọkụ eletrik ahụ na oghere dị n'ala.
  • Ejila ngwaọrụ arụ ọrụ na mmiri ma ọ bụ damp ọnọdụ.
  • Zere igbochi oghere ikuku iji gbochie ikpo oke ọkụ.
  • Anwala imepe ma ọ bụ rụzie ngwaọrụ ahụ. Nye ndị ọrụ ruru eru ọrụ niile.
  • The device is equipped with overload and short-circuit protection. However, always ensure proper load connections.
  • Safety standards: EN-61010-1 and safety transformer according to EN-61558-2-6.

3. Nhazi

Follow these steps to set up your PeakTech P 6145 power supply:

  1. Iwepu: Carefully remove the power supply from its packaging and inspect it for any signs of damage. Retain the packaging for future transport or storage.
  2. Nkwanye: Place the unit on a stable, level surface. Ensure adequate ventilation around the device, leaving at least 10 cm of space on all sides, especially around the rear fan.
  3. Njikọ ike: Connect the provided power cord to the AC input socket on the rear panel of the power supply and then to a suitable grounded mains outlet. Ensure the mains voltage matches the rating specified on the device.
  4. Nyocha mbụ: Before connecting any load, ensure all control knobs are set to their minimum positions.
N'azụ view of the PeakTech P 6145 Digital Double Laboratory Power Supply

Foto 3.1: N'azụ view of the PeakTech P 6145, showing the power input, fan, and ventilation grilles.

4. Ntuziaka ọrụ

The PeakTech P 6145 offers flexible operation with its dual adjustable outputs and a fixed output.

4.1 Ogwe ihu n'ihuview

  • Ngosipụta Dijitalụ: Two sets of displays show the output voltage (V) and current (A) for the Master and Slave channels.
  • Voltage Adjustment Knobs: Fine and coarse adjustment for output voltage on each channel.
  • Current Adjustment Knobs: Fine and coarse adjustment for output current limit on each channel.
  • Ọnụ ahịa mmepụta: 4mm safety sockets for Master (0-30V/0-5A), Slave (0-30V/0-5A), and Fixed (5V/3A) outputs.
  • Mode Selection Switches: For Master/Slave operation (Normal, Series, Parallel).
  • Output ON/OFF Button: Toggles the output for the adjustable channels. The fixed 5V/3A output is always active.
  • Ike mgba ọkụ: Isi mgba ọkụ maka otu.

4.2 Basic Operation (Independent Mode)

  1. Ensure the Master/Slave mode switch is set to NKWU.
  2. Turn on the power supply using the main power switch.
  3. Gbanwee voltage and current limit for the Master channel using its respective knobs. The displays will show the set values.
  4. Repeat for the Slave channel.
  5. Connect your load to the appropriate 4mm safety output terminals.
  6. Pịa MAPỤTARA/ Gbanyụọ button to enable the output. The displays will now show the actual voltage and current delivered to the load.
  7. For the fixed 5V/3A output, simply connect your load to its dedicated terminals.

4.3 Master/Slave Operation

The two adjustable channels can be configured for series or parallel operation:

  • Ụdị usoro: Họrọ Usoro on the mode switch. This combines the voltage of both channels, providing up to 60V (e.g., 30V + 30V) at the current limit of the Master channel (up to 5A). Connect the load to the Master output terminals.
  • Ụdị Ndekota: Họrọ MKWUO on the mode switch. This combines the current of both channels, providing up to 10A (e.g., 5A + 5A) at the voltage of the Master channel (up to 30V). Connect the load to the Master output terminals.

In both series and parallel modes, the Master channel controls the overall output, and the Slave channel automatically adjusts accordingly.

5. Nlekọta

Mmezi kwesịrị ekwesị na-eme ka ọkụ eletrik gị dị ogologo ma nwee ike ịrụ ọrụ nke ọma.

  • Nhicha: Disconnect the power supply from the mains before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
  • Igwe ikuku: Regularly check that the ventilation openings and fan are free from dust and debris. Use compressed air to clear any blockages if necessary.
  • Ndochi fiusi: If the unit fails to power on, check the fuse located in the power input socket on the rear panel. Replace it only with a fuse of the same type and rating (e.g., 250V/T3.15A).

6. Nchọpụta nsogbu

Ọ bụrụ na ị hụ nsogbu na ọkọnọ ike gị, lee nsogbu na ngwọta ndị a na-ahụkarị:

  • Enweghị ike:
    • Check if the power cord is securely connected to both the unit and the mains outlet.
    • Verify that the mains outlet is functional.
    • Check and replace the fuse if blown (refer to Section 5. Maintenance).
  • Enweghị mmepụta Voltage/Ugbu a:
    • Gbaa mbọ hụ na MAPỤTARA/ Gbanyụọ button is pressed (output enabled).
    • Lelee ma voltage and current limit knobs are set above zero.
    • Verify that the load is correctly connected and not short-circuited.
    • If the unit is in Constant Current (CC) mode, the current limit has been reached. Increase the current limit or reduce the load.
    • If the unit is in Constant Voltage (CV) mode, the voltage limit has been reached. Increase the voltage limit or reduce the load.
  • Overload/Short-Circuit Protection Activated:
    • The unit automatically protects itself from overload and short circuits. Disconnect the load, resolve the issue (e.g., reduce load resistance, fix short), and then re-enable the output.

If the problem persists after following these steps, contact customer support or a qualified service technician.

7. Nkọwapụta

NjirimaraNkọwapụta
Nọmba nlereanyaP 6145
Ọwa mmepụta2 x Adjustable, 1 x Fixed
Adjustable Output 1 (Master)0 - 30 V DC, 0 - 5 A DC
Adjustable Output 2 (Slave)0 - 30 V DC, 0 - 5 A DC
Mmepụta emeziri5V DC, 3 A
Ọnụ ahịa mmepụta4 mm Safety Sockets
NchedoOverload Protection, Short-Circuit Protection
Ụkpụrụ nchekwaEN-61010-1, EN-61558-2-6
Akụkụ (L x W x H)35.5 x 26.5 x 17 cm
IbuApproximately 9 g (Note: This weight seems unusually low for a power supply of this type and may be a data entry error. Please refer to product packaging for accurate weight.)

8. Akwụkwọ ikike na nkwado

For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your retailer or the manufacturer directly. Keep your proof of purchase for warranty claims.

© 2023 PeakTech. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.